304 Stainless Steel HMI housing with an IMD 17.3 inch panel PC installed
17.3 inch HMI housing with the operator strip for four 22 mm devices
17.3 inch HMI housing showing the display cutout
Dimensioned drawing of the 17.3 inch HMI housing
Dimensioned drawing of the 17.3 inch HMI housing with operator strip
Rear of the 17.3 inch HMI housing with VESA 100 pattern and cable glands
17.3 inch HMI housing built for an IMD touch monitor with an IMD mini PC inside
Inside the 17.3 inch HMI housing: IMD mini PC behind the touch monitor, rear cover off
17.3 inch touch monitor + mini PC HMI housing with the operator strip
Dimensioned drawing, 17.3 inch HMI housing for a touch monitor + mini PC
View in 3D

HMI enclosures · 304 stainless

17.3" HMI enclosure

304 Stainless Steel HMI Housing, 17.3", for an IMD Panel PC or Touch Monitor + Mini PC

$559.00Made to order
Built forIMD panel PC
Front panelDisplay cutout only

Design your cutoutsHoles, glands, pushbuttons or a display opening on any face, in 3D. We quote it.Start →

Different holes, your own drawing or a quantity quote? Request a quote

  • Made to order Lead time confirmed with your order
  • Rating IP65-type front seal with the display installed, manufacturer rated; not UL listed
  • Checkout Secure checkout by Industrial Monitor Direct
  • Display cutout included
  • Panel PC or monitor + mini PC
  • 304 Stainless Steel
  • Gasketed rear cover
  • VESA 100 rear
  • Optional operator strip

Interactive 3D

Turn it over before you order.

The model follows the configuration you pick above. Drag to rotate, pinch or scroll to zoom.

Loading 3D model…

Details

Specifications

A compact housing with a thin, even border around the display and the opening laser-cut to your exact IMD model. Build it two ways: for an IMD 17.3" panel PC, or for an IMD 17.3" touch monitor with an IMD mini PC on a bracket behind it, which gives you a sealed HMI with the computer you choose inside. A gasketed rear cover comes off for service, cable glands sit underneath, and the back takes a VESA 100 arm, a pedestal or a wall mount. Add the operator strip for four 22 mm pushbuttons, pilot lights or an E-stop.

Built for
IMD 17.3" panel PC, or IMD 17.3" touch monitor + IMD mini PC (IMDRT120 / 121 / 122); devices sold separately
Outside dimensions (H x W x D)
12.56 x 19.13 x 4.02 in for a panel PC; 6.22 in deep for monitor + mini PC; 15.47 in high with the operator strip
Inside dimensions (H x W x D, nominal)
12.44 × 19.02 × 3.84 in (316 × 483 × 97.6 mm)
Display cutout
Cut to the opening of your exact IMD model; largest 17.3" opening 441 x 274 mm
Material
304 stainless steel, #4 brushed finish
Rating
IP65-type front seal with the display installed (manufacturer rated, not UL listed)
Inside (monitor + mini PC)
Galvanized bracket and adapter plate for the mini PC behind the monitor, short internal cable runs
Rear
Removable gasketed cover, 8 screws, VESA 100 pattern
Cable entry
Two cable glands on the bottom; three with the monitor + mini PC build
Operator strip
Optional: four 22.3 mm holes for 22 mm devices (devices not included)
Lead time
Made to order; lead time confirmed with your order
Dimensioned drawing of the 17.3 inch HMI housing
Dimensioned drawing of the 17.3 inch HMI housing

Order it with the display

Add the IMD 17.3" panel PC, or the touch monitor and a mini PC, to the same order and we cut and fit the housing for those units. Ordering the housing alone? Name the IMD models in the order note.

304 stainless: is it the right grade?

304 suits indoor washdown, food and beverage lines and most outdoor installs. For coastal air, brine or chlorinated cleaners, choose 316L. Compare 304 and 316L.

Custom version

Request a quote for this enclosure

Extra holes, a different cutout, your own drawing or a quantity quote: tell us what you need and attach a drawing if you have one. Our engineers check it and reply by email with a quote. Custom work is quoted, not priced online; the lead time is confirmed with your quote.

Design your cutoutsHoles, glands, pushbuttons or a display opening on any face, in 3D. We quote it.Start →

Wall-mount enclosures are manufacturer-rated NEMA 4X-type / IP66 - not UL listed. HMI enclosures are IP65-type at the front seal with the display installed. Once cutouts are added, the rating of the finished enclosure depends on properly rated components and cable glands being installed in every opening.

We reply from [email protected]. Nothing is emailed to you automatically; this page shows your RFQ number.

Complete the build

The hardware that goes inside, from Industrial Monitor Direct.

Panel PC

IMD panel PCs that fit this housing

Fanless industrial touchscreen computers. Order one with the enclosure and the opening is cut to that model.

All IMD panel PCs

Touch monitor

IMD industrial touch monitors

For the monitor + mini PC build: the touch monitor sits in the front, the mini PC on a bracket behind it.

Shop IMD touch monitors

Mini PC

IMD fanless mini PCs

The IMDRT120, 121 and 122 series fit the mini PC configuration of this housing.

Shop IMD mini PCs

Nearby sizes

Compare