Short answer: mount the SCADA host and the touchscreen in a stainless box the manufacturer rates NEMA 4X / IP66, and let heat, not the screen, set the size. A sealed 24 x 20 x 10 in [610 x 508 x 254 mm] 316L box sheds about 44 W for a 10 C rise at a 30 C shop, so a 30 W fanless thin client fits with room to spare and a 250 W tower PC does not: the tower drives the walls about 57 C above ambient. You have three moves — seal the box and cool it with a heat exchanger or a cooling unit, order a bigger box, or leave the host in the control room and put only a thin client at the screen. The numbers below settle each case.
What the shop throws at the station
A SCADA station at a machining cell or a washdown line meets four things at once, and each one points at a different line of the order:
- Hose water. Your washdown routine soaks everything mounted at the machine; Type 4 is the rating built for exactly that stream.
- Coolant mist and chlorides. Water-miscible coolant dries to a chloride-bearing film, and chloride deposits pit 304 stainless even at room temperature, so the material follows the mist rather than the price list.
- Heat. A shop without climate control sits near 30 C for much of the year and touches 35 C on summer afternoons; design to the measured peak, because the sealed-wall margin lives or dies there.
- Cooldown swings. A sealed box that runs all shift stays warm after the line stops; the air inside cools past its dew point and water films the walls. The way a sealed box holds and releases heat decides whether you see this — how much heat a sealed enclosure holds explains the swing.
What Type 4X stands for
NEMA 250 defines the Type 4 test around a fire-hose-style stream: the enclosure has to exclude at least 65 gal/min [4.1 L/s] of water from a 1 in nozzle held 10 ft [3 m] away for 5 min. Type 4X is that plus corrosion resistance — Table 5-1D of NEMA 250 gives a Type 4X box another 200 h of salt spray, judged against a type 304 stainless specimen. The same box usually carries the matching IEC 60529 code, IP66: dust-tight, and protected against powerful jets from a 12.5 mm nozzle at 100 L/min.
Keep the two numbers straight on a US job: NEC 110.28 states that IP ratings are not a substitute for enclosure type ratings, so the washdown specification asks for the Type 4X number and treats the IP code as the international twin. NEMA publishes the type definitions; it does not test, certify or endorse enclosures. Our boxes are rated NEMA 4X / IP66 by the manufacturer; not UL listed.
Where the computing host lives
The screen never needed a PC bolted beside it; the real choice is how much heat you seal inside the rated box. SCADA delivered by browser or a dedicated client can run on a host in the clean control room, and the station then holds a touchscreen plus a small client device. That is why the heat math below decides the architecture as much as the enclosure does.
| Arrangement | Heat sealed inside | Rating path | Choose it when |
|---|---|---|---|
| All-in-one panel PC in a stainless HMI housing | The panel PC's full wattage, in a compact housing | Manufacturer rated, IP65-type front seal with the display installed | One station, 7 to 23.8 in screens, quickest install |
| Host PC in a custom Type 4X box, display cut into the door | Host, display and network switch — hundreds of watts is normal | Custom box, manufacturer rated Type 4X for the specified design | The host must live at the machine |
| Thin client at the screen, host in the control room | Tens of watts: at 30 W the same box rises 7 C where a 250 W host rises 57 C | Same custom box; heat nearly stops mattering | Browser-delivered SCADA suits your plant |
The middle row is the case this article sizes in detail, because it is also the worst case: if the walls survive a 250 W host, the other two arrangements pass without ceremony.
The sealed-wall heat rule
A sealed box sheds heat through its walls by natural convection, and one line gives the answer. Stainless steel transfers about 3.7 W per square metre of wall per C of difference with still air on both sides; painted steel manages about 5.5 W/m²K and plastic about 3.5 W/m²K.
Wall area comes from the outer dimensions: add the six faces in square inches and multiply by 0.000645 to reach square metres. The non-ventilated enclosure heat dissipation sizing article runs the full method. Two corrections matter before you trust the result. Sun on an outdoor wall adds heat of its own, so an outside station carries a load this formula ignores — the outdoor real-heat-gain article works that side. And the average hides hot spots: a host's power supply sits well above box average unless you give hot parts room to convect, which is the subject of the component layout article.
A 250 W host in a 24 x 20 x 10 in sealed 316L box at 30 C
Inputs, each with its source:
- 250 W of host heat — a worked-example assumption for a tower PC; replace it with your build's measured draw under load.
- 24 x 20 x 10 in [610 x 508 x 254 mm] outer — the custom box this example orders; you define the size.
- 3.7 W/m²K — stainless wall transfer, still air on both sides.
- 30 C shop peak — the design ambient; a 35 C floor changes the result, shown at the end.
- 40 C electronics ambient — what most drives and electronics assume unless the datasheet allows more.
The rule in words: temperature rise equals watts in, divided by wall conductance (transfer coefficient times area).
- Area: 2 × (24 × 20) + 2 × (24 × 10) + 2 × (20 × 10) = 960 + 480 + 400 = 1,840 in², and 1,840 × 0.000645 = 1.19 m².
- Conductance: 3.7 × 1.19 = 4.4 W/C.
- Rise: 250 ÷ 4.4 = 57 C, so the inside sits near 30 + 57 = 87 C — 47 C over the 40 C the electronics assume. Sealed, the tower fails.
Flip the same sum for the sealed limit: 4.4 × (40 − 30) = 44 W is all this box clears. Check the thin client the same way: 30 ÷ 4.4 = 6.8 C of rise, so the box lands near 37 C inside with margin to spare.
Decision: below about 45 W of internal heat, order this box sealed and done. Above 45 W you add sealed cooling, grow the box, or move the host out. At a 35 C shop the same walls clear 4.4 × 5 = 22 W, so a hotter floor halves the sealed budget — run your own peak through the formula before you order.
Cooling that keeps the rating
Sealed cooling first, because it keeps the Type 4X story intact:
- Air-to-air heat exchanger. The box stays closed; the exchanger moves heat only while the inside runs hotter than the shop, and its capacity falls as that difference narrows. What the Type 4 side demands of the unit — sealing, gaskets, mounting — is the subject of the NEMA 4 heat exchanger requirements article.
- Enclosure cooling unit. Refrigerant-based, it pumps heat out even with the box near shop temperature. Your 250 W host is 250 × 3.412 = 853 Btu/h, so you pick capacity at the design inside-to-ambient difference from the manufacturer's curves, with margin.
- Fan-filter pair. The most airflow per unit of money, and the rating-killer: the assembly takes the fan-filter's own type. A Type 12 fan-filter bolted to a 4X box leaves you a Type 12 assembly in a washdown zone.
So the fan-filter belongs on the dry side of the shop; sealed heat moves with the exchanger or the unit. In a dusty shop the exchanger's ambient-side passages clog and airflow drops quietly — the heat exchanger cleaning when airflow drops article gives the symptoms and the interval. The fan vs air conditioner vs heat exchanger comparison carries the full sizing trade.
The touchscreen on the door
Start from the panel, not the box. A 21.5 in 16:9 panel shows an active area about 18.7 x 10.5 in [476 x 268 mm]; on a 24 in wide door that leaves about 2.6 in per side and 4.8 in above and below for the gasket line and fixings. A 23.8 in panel runs about 20.7 x 11.7 in [527 x 296 mm] and leaves only about 1.6 in per side on that same door; widen the door for that screen instead of shaving the gasket margin. Take the final cutout from the display's mechanical drawing — the active area is where the arithmetic starts, the bezel is what you cut for.
Every other penetration is a round hole closed with a gland matched to the cable OD, and the cutouts, glands and HMI windows guide covers positions, hole sizes and the sealing detail that keeps the Type. When the door starts to crowd, the other route is one of our HMI enclosures built around the panel PC: the 23.8 in housing and the 21.5 in housing carry the display, the computing bracket and a VESA 100 rear mount, manufacturer rated with an IP65-type front seal once the display is installed. The display-in-door case has its own NEMA 4X touchscreen walkthrough.
304 or 316L
304 with a #4 brushed finish is the default for indoor washdown, food and beverage and most outdoor sites; 316L earns its keep where salt air, brine, chlorides or chemical splash reach the walls. Two chloride facts settle most arguments. Both grades face chloride stress-corrosion cracking from about 60 C (140 F), so a hot wall under a chloride film is the worst combination for either — molybdenum does not move that threshold. And the molybdenum in 316L raises pitting and crevice resistance, which is exactly what a damp gasket line or a drying coolant film attacks. A station above a washdown pit with coolant concentrate in the air gets 316L; the dry end of a packaging line hosed daily is fine in 304. Wet-dry cycling is what rusts even 316L in service — the why wet-dry cycling rusts 316L article explains the mechanism, and rinse-down habits matter as much as the grade.
What to put on the order
| Line | What to send |
|---|---|
| Material | 304 #4 brushed for daily hose-down; 316L for chloride mist, brine or salt air |
| Rating | Type 4X, manufacturer rated for the specified design; state the washdown duty and location |
| Outer size | From the heat math first — the worked box is 24 x 20 x 10 in for a build under 45 W |
| Display cutout | Panel active area plus bezel, per the display supplier's mechanical drawing |
| Glands | Count, positions, cable ODs; round holes, glands rated for the same enclosure type |
| Backplate | Plate and mounting positions; keep hot parts high and clear of each other |
| Heat plan | Sealed watts under 45 W here, or name the exchanger or cooling unit with its rated capacity |
| Door gear | Hinge side away from direct spray; latch and lock choice |
We build the box to that drawing and deliver it in 10 business days, counted from your order — for custom work, from your approval of the drawing. If you would rather shortlist first, the enclosure selector filters by environment, listing and inside size, and the custom box builder takes your dimensions and cutouts directly.
Catalog dimensions to compare
Compare these catalog dimensions with your component layout. Open each enclosure for its rating, material and usable space, then check those specifications against your application.
| Enclosure | Material | Outside H x W x D / display | Rating |
|---|---|---|---|
| 23.8" HMI enclosure | 304 stainless | 15.91 x 24.96 x 4.02 in | IP65-type front seal with the display installed, manufacturer rated; not UL listed |
| 21.5" HMI enclosure | 304 stainless | 14.69 x 23.03 x 3.86 in | IP65-type front seal with the display installed, manufacturer rated; not UL listed |
| 24 × 20 × 10 in | 316L stainless | 24 x 20 x 10 in | Rated NEMA 4X / IP66 by the manufacturer; not UL listed |
| 8" HMI enclosure | 304 stainless | 8.39 x 9.98 x 3.92 in | IP65-type front seal with the display installed, manufacturer rated; not UL listed |
Questions
Does the touchscreen at a SCADA station need its own PC?
No. Browser- or client-delivered SCADA lets the host run in the clean control room, so the washdown box holds only a touchscreen and a thin client. At 30 W, a thin client raises a 24 x 20 x 10 in stainless box about 7 C, so a 30 C shop lands near 37 C inside — well under the 40 C most electronics assume. The same box with a 250 W host rises about 57 C.
Can I keep the box sealed and still cool a 250 W host?
Yes, with sealed accessories. Your 250 W host is 250 × 3.412 = about 853 Btu/h, so pick a heat exchanger or cooling unit whose rated capacity at your design inside-to-ambient difference clears that with margin. An air-to-air exchanger also needs the box running hotter than the shop to work. A fan-filter pair would drop the assembly to the fan-filter's own enclosure type.
Is 304 stainless good enough, or do I need 316L?
304 is the default for indoor washdown, food and beverage and most outdoor sites; step to 316L when salt air, brine, chloride-bearing coolant or chemical splash reaches the box. Both grades face chloride stress-corrosion cracking from about 60 C (140 F), so keep chloride deposits off hot walls; the molybdenum in 316L buys pitting and crevice resistance where gaskets stay damp.
How much heat does a sealed stainless box shed?
Multiply 3.7 W/m²K by the wall area in m² by the rise you can allow. The 24 x 20 x 10 in box in this article has 1.19 m² of wall, so a 10 C rise clears about 44 W at a 30 C shop with 40 C electronics. A 20 C rise clears 88 W but puts the inside at 50 C — over the 40 C most electronics assume.
Are these enclosures UL listed?
No. Every rating in this article is the manufacturer's rating for the specified design; the enclosures are not UL listed. A UL listed enclosure has been evaluated by UL to UL 50E, which is a different document from the manufacturer rating. If your project specification calls for that listing, raise it before you order.