Stainless enclosure cross-reference

Replacing a stainless wall-mount enclosure from another maker? Type its part number below. The tool reads the nominal outside size (H x W x D) and the grade from the maker's published numbering, then points you to our enclosure of the same nominal size and grade, the nearest larger standard size, or a custom build in the enclosure builder. The table lists every one of our sizes with the part numbers of the same nominal size. Check the panel size, latching and mounting before you substitute.

Try:

Dimensional cross only: same nominal outside size and grade. Hoffman, Saginaw, Wiegmann and B-Line are trademarks of their owners; we are not affiliated. Our enclosures are rated NEMA 4X / IP66 by the manufacturer and are not UL listed. Check the panel size, latching and mounting before substituting.

Part-number patterns the tool reads (stainless single-door wall-mount enclosures only)
MakerPatternExampleGrade code
Hoffman (nVent), continuous hinge with clampsA + height + H + width + depth, two digits each, + SSLP; 3-point latch versions end 3PTA16H1206SSLP = 16 × 12 × 6 inSSLP = 304, SS6LP = 316L
Saginaw Control & Engineering, LP seriesSCE- + height + H + width + depth, two digits each, + SSLPSCE-24H2006SSLP = 24 × 20 × 6 inSSLP = 304, SS6LP = 316/316L
Wiegmann (Hubbell), SSN4 seriesSSN4 + height + width + depth, two digits each (nominal depth)SSN4201610A = 20 × 16 × 10 inno suffix = 304, A = 316L
B-Line (Eaton), 4XS seriesheight + width (two digits each) + depth + -4XS16126-4XSS6 = 16 × 12 × 6 in-4XS = 304, -4XSS6 = 316

Size by size

Every size we build, with the same nominal sizes

Our sizes and the published part numbers of the same nominal size and grade
Our size (outside H × W × D)304316L
6 × 4 × 4 in6 × 4 × 4 in, 3046 × 4 × 4 in, 316L
6 × 6 × 4 in6 × 6 × 4 in, 3046 × 6 × 4 in, 316L
8 × 6 × 4 in8 × 6 × 4 in, 3048 × 6 × 4 in, 316L
8 × 8 × 4 in8 × 8 × 4 in, 3048 × 8 × 4 in, 316L
10 × 8 × 4 in10 × 8 × 4 in, 30410 × 8 × 4 in, 316L
10 × 8 × 6 in10 × 8 × 6 in, 30410 × 8 × 6 in, 316L
12 × 10 × 6 in12 × 10 × 6 in, 30412 × 10 × 6 in, 316L
12 × 12 × 6 in12 × 12 × 6 in, 30412 × 12 × 6 in, 316L
12 × 10 × 8 in12 × 10 × 8 in, 30412 × 10 × 8 in, 316L
14 × 12 × 6 in14 × 12 × 6 in, 30414 × 12 × 6 in, 316L
16 × 12 × 6 in16 × 12 × 6 in, 304same nominal size as Hoffman A16H1206SSLP, Saginaw SCE-16H1206SSLP, Wiegmann SSN416120616 × 12 × 6 in, 316Lsame nominal size as Hoffman A16H1206SS6LP, Saginaw SCE-16H1206SS6LP
14 × 12 × 8 in14 × 12 × 8 in, 30414 × 12 × 8 in, 316L
16 × 14 × 6 in16 × 14 × 6 in, 30416 × 14 × 6 in, 316L
16 × 12 × 8 in16 × 12 × 8 in, 304same nominal size as Hoffman A16H1208SSLP, Saginaw SCE-16H1208SSLP, Wiegmann SSN416120816 × 12 × 8 in, 316Lsame nominal size as Hoffman A16H1208SS6LP, Saginaw SCE-16H1208SS6LP
16 × 16 × 6 in16 × 16 × 6 in, 304same nominal size as Hoffman A16H1606SSLP, Saginaw SCE-16H1606SSLP, Wiegmann SSN416160616 × 16 × 6 in, 316Lsame nominal size as Hoffman A16H1606SS6LP, Saginaw SCE-16H1606SS6LP, Wiegmann SSN4161606A
16 × 14 × 8 in16 × 14 × 8 in, 30416 × 14 × 8 in, 316L
16 × 12 × 10 in16 × 12 × 10 in, 30416 × 12 × 10 in, 316L
16 × 20 × 6 in16 × 20 × 6 in, 304same nominal size as Hoffman A16H2006SSLP, Saginaw SCE-16H2006SSLP16 × 20 × 6 in, 316Lsame nominal size as Hoffman A16H2006SS6LP, Saginaw SCE-16H2006SS6LP
20 × 16 × 6 in20 × 16 × 6 in, 304same nominal size as Hoffman A20H1606SSLP, Saginaw SCE-20H1606SSLP, Wiegmann SSN420160620 × 16 × 6 in, 316Lsame nominal size as Hoffman A20H1606SS6LP, Saginaw SCE-20H1606SS6LP
16 × 16 × 8 in16 × 16 × 8 in, 30416 × 16 × 8 in, 316L
20 × 20 × 6 in20 × 20 × 6 in, 304same nominal size as Hoffman A20H2006SSLP, Saginaw SCE-20H2006SSLP, Wiegmann SSN420200620 × 20 × 6 in, 316Lsame nominal size as Hoffman A20H2006SS6LP, Saginaw SCE-20H2006SS6LP
16 × 20 × 8 in16 × 20 × 8 in, 30416 × 20 × 8 in, 316L
20 × 16 × 8 in20 × 16 × 8 in, 304same nominal size as Hoffman A20H1608SSLP, Saginaw SCE-20H1608SSLP, Wiegmann SSN420160820 × 16 × 8 in, 316Lsame nominal size as Hoffman A20H1608SS6LP, Saginaw SCE-20H1608SS6LP
24 × 20 × 6 in24 × 20 × 6 in, 304same nominal size as Hoffman A24H2006SSLP, Saginaw SCE-24H2006SSLP, Wiegmann SSN424200624 × 20 × 6 in, 316Lsame nominal size as Hoffman A24H2006SS6LP, Saginaw SCE-24H2006SS6LP
24 × 16 × 8 in24 × 16 × 8 in, 304same nominal size as Hoffman A24H1608SSLP, Saginaw SCE-24H1608SSLP24 × 16 × 8 in, 316Lsame nominal size as Hoffman A24H1608SS6LP, Saginaw SCE-24H1608SS6LP, Wiegmann SSN4241608A
16 × 20 × 10 in16 × 20 × 10 in, 30416 × 20 × 10 in, 316L
20 × 16 × 10 in20 × 16 × 10 in, 304same nominal size as Hoffman A20H1610SSLP, Saginaw SCE-20H1610SSLP, Wiegmann SSN420161020 × 16 × 10 in, 316Lsame nominal size as Hoffman A20H1610SS6LP, Saginaw SCE-20H1610SS6LP, Wiegmann SSN4201610A
20 × 20 × 8 in20 × 20 × 8 in, 304same nominal size as Hoffman A20H2008SSLP20 × 20 × 8 in, 316Lsame nominal size as Hoffman A20H2008SS6LP, Wiegmann SSN4202008A
24 × 24 × 6 in24 × 24 × 6 in, 304same nominal size as Hoffman A24H2406SSLP, Saginaw SCE-24H2406SSLP24 × 24 × 6 in, 316Lsame nominal size as Hoffman A24H2406SS6LP
20 × 24 × 8 in20 × 24 × 8 in, 304same nominal size as Hoffman A20H2408SSLP, Saginaw SCE-20H2408SSLP, Wiegmann SSN420240820 × 24 × 8 in, 316Lsame nominal size as Hoffman A20H2408SS6LP, Saginaw SCE-20H2408SS6LP
24 × 16 × 10 in24 × 16 × 10 in, 30424 × 16 × 10 in, 316L
24 × 20 × 8 in24 × 20 × 8 in, 304same nominal size as Hoffman A24H2008SSLP, Saginaw SCE-24H2008SSLP, Wiegmann SSN424200824 × 20 × 8 in, 316Lsame nominal size as Hoffman A24H2008SS6LP, Saginaw SCE-24H2008SS6LP, Wiegmann SSN4242008A
20 × 20 × 10 in20 × 20 × 10 in, 30420 × 20 × 10 in, 316L
24 × 24 × 8 in24 × 24 × 8 in, 304same nominal size as Hoffman A24H2408SSLP, Saginaw SCE-24H2408SSLP, Wiegmann SSN424240824 × 24 × 8 in, 316Lsame nominal size as Hoffman A24H2408SS6LP, Saginaw SCE-24H2408SS6LP, Wiegmann SSN4242408A
20 × 20 × 12 in20 × 20 × 12 in, 30420 × 20 × 12 in, 316L
24 × 20 × 10 in24 × 20 × 10 in, 304same nominal size as Hoffman A24H2010SSLP, Saginaw SCE-24H2010SSLP, Wiegmann SSN424201024 × 20 × 10 in, 316Lsame nominal size as Hoffman A24H2010SS6LP, Saginaw SCE-24H2010SS6LP
30 × 20 × 8 in30 × 20 × 8 in, 304same nominal size as Hoffman A30H2008SSLP, Saginaw SCE-30H2008SSLP30 × 20 × 8 in, 316Lsame nominal size as Hoffman A30H2008SS6LP, Saginaw SCE-30H2008SS6LP
24 × 20 × 12 in24 × 20 × 12 in, 30424 × 20 × 12 in, 316L
24 × 24 × 10 in24 × 24 × 10 in, 30424 × 24 × 10 in, 316L
24 × 30 × 8 in24 × 30 × 8 in, 304same nominal size as Hoffman A24H3008SSLP, Saginaw SCE-24H3008SSLP, Wiegmann SSN424300824 × 30 × 8 in, 316Lsame nominal size as Hoffman A24H3008SS6LP, Saginaw SCE-24H3008SS6LP
30 × 24 × 8 in30 × 24 × 8 in, 304same nominal size as Hoffman A30H2408SSLP, Saginaw SCE-30H2408SSLP, Wiegmann SSN430240830 × 24 × 8 in, 316Lsame nominal size as Hoffman A30H2408SS6LP, Saginaw SCE-30H2408SS6LP
24 × 24 × 12 in24 × 24 × 12 in, 304same nominal size as Hoffman A24H2412SSLP, Saginaw SCE-24H2412SSLP, Wiegmann SSN424241224 × 24 × 12 in, 316Lsame nominal size as Hoffman A24H2412SS6LP, Saginaw SCE-24H2412SS6LP
36 × 24 × 8 in36 × 24 × 8 in, 304same nominal size as Hoffman A36H2408SSLP, Saginaw SCE-36H2408SSLP36 × 24 × 8 in, 316Lsame nominal size as Hoffman A36H2408SS6LP, Saginaw SCE-36H2408SS6LP
30 × 24 × 10 in30 × 24 × 10 in, 304same nominal size as Hoffman A30H2410SSLP, Wiegmann SSN430241030 × 24 × 10 in, 316Lsame nominal size as Hoffman A30H2410SS6LP, Wiegmann SSN4302410A
30 × 30 × 8 in30 × 30 × 8 in, 304same nominal size as Hoffman A30H3008SSLP, Saginaw SCE-30H3008SSLP, Wiegmann SSN430300830 × 30 × 8 in, 316Lsame nominal size as Hoffman A30H3008SS6LP, Saginaw SCE-30H3008SS6LP
30 × 24 × 12 in30 × 24 × 12 in, 304same nominal size as Hoffman A30H2412SSLP, Saginaw SCE-30H2412SSLP30 × 24 × 12 in, 316Lsame nominal size as Hoffman A30H2412SS6LP, Saginaw SCE-30H2412SS6LP
36 × 24 × 10 in36 × 24 × 10 in, 304same nominal size as Hoffman A36H2410SSLP, Saginaw SCE-36H2410SSLP, Wiegmann SSN436241036 × 24 × 10 in, 316Lsame nominal size as Hoffman A36H2410SS6LP, Saginaw SCE-36H2410SS6LP
36 × 30 × 8 in36 × 30 × 8 in, 304same nominal size as Hoffman A36H3008SSLP, Saginaw SCE-36H3008SSLP36 × 30 × 8 in, 316Lsame nominal size as Hoffman A36H3008SS6LP, Saginaw SCE-36H3008SS6LP
30 × 30 × 10 in30 × 30 × 10 in, 30430 × 30 × 10 in, 316L
36 × 24 × 12 in36 × 24 × 12 in, 30436 × 24 × 12 in, 316L
30 × 30 × 12 in30 × 30 × 12 in, 30430 × 30 × 12 in, 316L
36 × 30 × 10 in36 × 30 × 10 in, 304same nominal size as Hoffman A36H3010SSLP, Saginaw SCE-36H3010SSLP, Wiegmann SSN436301036 × 30 × 10 in, 316Lsame nominal size as Hoffman A36H3010SS6LP, Saginaw SCE-36H3010SS6LP, Wiegmann SSN4363010A
30 × 24 × 16 in30 × 24 × 16 in, 304same nominal size as Hoffman A30H2416SSLP, Saginaw SCE-30H2416SSLP30 × 24 × 16 in, 316Lsame nominal size as Hoffman A30H2416SS6LP, Saginaw SCE-30H2416SS6LP
42 × 36 × 8 in42 × 36 × 8 in, 304same nominal size as Hoffman A42H3608SSLP, Saginaw SCE-42H3608SSLP42 × 36 × 8 in, 316Lsame nominal size as Hoffman A42H3608SS6LP, Saginaw SCE-42H3608SS6LP
42 × 30 × 10 in42 × 30 × 10 in, 304same nominal size as Hoffman A42H3010SSLP, Saginaw SCE-42H3010SSLP, Wiegmann SSN442301042 × 30 × 10 in, 316Lsame nominal size as Hoffman A42H3010SS6LP, Saginaw SCE-42H3010SS6LP
36 × 30 × 12 in36 × 30 × 12 in, 304same nominal size as Hoffman A36H3012SSLP, Saginaw SCE-36H3012SSLP, Wiegmann SSN436301236 × 30 × 12 in, 316Lsame nominal size as Hoffman A36H3012SS6LP, Saginaw SCE-36H3012SS6LP
48 × 36 × 8 in48 × 36 × 8 in, 304same nominal size as Hoffman A48H3608SSLP, Saginaw SCE-48H3608SSLP48 × 36 × 8 in, 316Lsame nominal size as Hoffman A48H3608SS6LP, Saginaw SCE-48H3608SS6LP
36 × 36 × 12 in36 × 36 × 12 in, 304same nominal size as Hoffman A36H3612SSLP, Saginaw SCE-36H3612SSLP, Wiegmann SSN436361236 × 36 × 12 in, 316Lsame nominal size as Hoffman A36H3612SS6LP, Saginaw SCE-36H3612SS6LP
36 × 30 × 16 in36 × 30 × 16 in, 304same nominal size as Hoffman A36H3016SSLP, Saginaw SCE-36H3016SSLP36 × 30 × 16 in, 316Lsame nominal size as Hoffman A36H3016SS6LP, Saginaw SCE-36H3016SS6LP
48 × 36 × 10 in48 × 36 × 10 in, 304same nominal size as Hoffman A48H3610SSLP, Saginaw SCE-48H3610SSLP, Wiegmann SSN448361048 × 36 × 10 in, 316Lsame nominal size as Hoffman A48H3610SS6LP, Wiegmann SSN4483610A
42 × 36 × 12 in42 × 36 × 12 in, 30442 × 36 × 12 in, 316L
48 × 36 × 12 in48 × 36 × 12 in, 304same nominal size as Hoffman A48H3612SSLP, Saginaw SCE-48H3612SSLP, Wiegmann SSN448361248 × 36 × 12 in, 316Lsame nominal size as Hoffman A48H3612SS6LP, Saginaw SCE-48H3612SS6LP
60 × 36 × 12 in60 × 36 × 12 in, 304same nominal size as Hoffman A60H3612SSLP, Saginaw SCE-60H3612SSLP60 × 36 × 12 in, 316Lsame nominal size as Hoffman A60H3612SS6LP, Saginaw SCE-60H3612SS6LP
48 × 36 × 16 in48 × 36 × 16 in, 304same nominal size as Hoffman A48H3616SSLP, Saginaw SCE-48H3616SSLP48 × 36 × 16 in, 316Lsame nominal size as Hoffman A48H3616SS6LP, Saginaw SCE-48H3616SS6LP
60 × 36 × 16 in60 × 36 × 16 in, 304same nominal size as Hoffman A60H3616SSLP60 × 36 × 16 in, 316Lsame nominal size as Hoffman A60H3616SS6LP

78 of our 130 enclosures share a nominal size and grade with a listed part. Part lists as published by each maker; a part number in the pattern but not in the list is read, but not confirmed.

Buying guides

Before you substitute.

All guides

Not a standard size?

Your size, material and cutouts, delivered in 10 business days.

Set width, height and depth, the material and the NEMA type in the enclosure builder, or send your drawing. From one piece, anywhere in the world. Counted from your order; for custom work, from your approval of the drawing.

Asked and answered

Cross-reference: questions

Is your enclosure a drop-in replacement?

It is a dimensional cross only: the same nominal outside size and the same grade. Mounting-foot positions, the mounting panel size and holes, the latching and the inside depth can differ, so compare them with the CAD of our size (every product page and the CAD library) before you substitute.

Which part numbers can the tool read?

Stainless single-door wall-mount enclosures with the size in the part number: Hoffman A…SSLP and A…SS6LP (and their 3PT versions), Saginaw SCE-…SSLP and SCE-…SS6LP, Wiegmann SSN4… and B-Line …-4XS / -4XSS6. You can also type a size, for example 16 x 12 x 6 316.

What if you have no matching size?

The tool shows our nearest larger standard size in the same grade, and the enclosure builder makes any size in 304 or 316L from one piece, delivered in 10 business days.

Why does a Wiegmann depth look different?

The SSN4 part number carries the nominal depth; the maker's sheet lists the actual depth about 1.03 in deeper (SSN4161206: 16.00 x 12.00 x 7.03 in). Our depths are the outside body depth, so compare the real numbers.

Are your sizes outside dimensions?

Yes: outside body H x W x D. The wall-mount feet, hinge and latch add to it (our 16 x 12 x 6 in is 494.4 x 312 x 162.9 mm overall); the overall size is on every product page and drawing.