NEMA 4X enclosures
NEMA 4X enclosures keep out windblown dust, rain, splashing and hose-directed water, are undamaged by ice forming on the outside, and add a corrosion test that Type 4 does not have. That makes 4X the usual choice for washdown, outdoor and corrosive locations. We build 65 wall-mount sizes, 6 × 4 × 4 in to 60 × 36 × 16 in, each in 304 and 316L stainless with a #4 brushed finish, rated NEMA 4X / IP66 by the manufacturer (not UL listed) and delivered in 10 business days.
- Sizes
- 65 wall-mount sizes, 6 × 4 × 4 in to 60 × 36 × 16 in (outside H × W × D, body only)
- Footprints
- 29 height × width footprints; depths 4, 6, 8, 10, 12 and 16 in
- Grades
- 304 and 316L stainless, #4 brushed; which grade
- Rating
- NEMA 4X / IP66 by the manufacturer; not UL listed
- Door
- Continuous stainless hinge, full door height; continuous gasket
- Latching
- Quarter-turn latch with key: 6 to 16 in tall; 2 quarter-turn latches, top one keyed: 20 to 24 in tall; 3-point swing handle with key lock: 30 to 60 in tall
- Inside
- Removable galvanized mounting panel on welded studs; ground studs on body and door
- Mounting
- Four wall-mount feet, outside the sealed box
- CAD
- STEP, DWG, DXF and PDF for every size: CAD library
- Delivery
- Made to order, delivered in 10 business days, anywhere in the world
| NEMA Type 4 | NEMA Type 4X | |
|---|---|---|
| Dust | Windblown dust | Same |
| Water | Rain, sleet, snow, splashing and hose-directed water | Same |
| Ice | Undamaged by ice forming on the outside | Same |
| Corrosion | The outdoor salt-spray test every outdoor type gets: 600 hours against a G90 galvanized steel specimen | Another 200 hours of salt spray, compared with an AISI 304 stainless steel specimen |
| Use it for | Indoor or outdoor sites with water but no corrosive exposure | Washdown chemicals, salt air, de-icing salt, wastewater, chemical areas |
IP66 is a different test: an IEC 60529 code for dust-tight and powerful water jets that says nothing about corrosion, ice or gaskets. NEMA's own table shows Types 4 and 4X meeting or exceeding IP66, not the reverse. NEMA 4 vs 4X vs IP66, compared.
By footprint
Every size, grouped by height × width
| Footprint (H × W) | Depths in 304 | Depths in 316L | Sheet | Latching |
|---|---|---|---|---|
| 6 × 4 in | 4 in | 4 in | 1.2 mm | Quarter-turn latch with key |
| 6 × 6 in | 4 in | 4 in | 1.2 mm | Quarter-turn latch with key |
| 8 × 6 in | 4 in | 4 in | 1.2 mm | Quarter-turn latch with key |
| 8 × 8 in | 4 in | 4 in | 1.2 mm | Quarter-turn latch with key |
| 10 × 8 in | 4 in 6 in | 4 in 6 in | 1.2 mm | Quarter-turn latch with key |
| 12 × 10 in | 6 in 8 in | 6 in 8 in | 1.2 mm | Quarter-turn latch with key |
| 12 × 12 in | 6 in | 6 in | 1.2 mm | Quarter-turn latch with key |
| 14 × 12 in | 6 in 8 in | 6 in 8 in | 1.2 mm | Quarter-turn latch with key |
| 16 × 12 in | 6 in 8 in 10 in | 6 in 8 in 10 in | 1.5 mm | Quarter-turn latch with key |
| 16 × 14 in | 6 in 8 in | 6 in 8 in | 1.5 mm | Quarter-turn latch with key |
| 16 × 16 in | 6 in 8 in | 6 in 8 in | 1.5 mm | Quarter-turn latch with key |
| 16 × 20 in | 6 in 8 in 10 in | 6 in 8 in 10 in | 1.5 mm | Quarter-turn latch with key |
| 20 × 16 in | 6 in 8 in 10 in | 6 in 8 in 10 in | 1.5 mm | 2 quarter-turn latches, top one keyed |
| 24 × 16 in | 8 in 10 in | 8 in 10 in | 1.5 mm | 2 quarter-turn latches, top one keyed |
| 20 × 20 in | 6 in 8 in 10 in 12 in | 6 in 8 in 10 in 12 in | 1.5 mm | 2 quarter-turn latches, top one keyed |
| 20 × 24 in | 8 in | 8 in | 1.5 mm | 2 quarter-turn latches, top one keyed |
| 24 × 20 in | 6 in 8 in 10 in 12 in | 6 in 8 in 10 in 12 in | 1.5 mm | 2 quarter-turn latches, top one keyed |
| 24 × 24 in | 6 in 8 in 10 in 12 in | 6 in 8 in 10 in 12 in | 1.5 mm | 2 quarter-turn latches, top one keyed |
| 30 × 20 in | 8 in | 8 in | 1.5 mm | 3-point swing handle with key lock |
| 24 × 30 in | 8 in | 8 in | 1.5 mm | 2 quarter-turn latches, top one keyed |
| 30 × 24 in | 8 in 10 in 12 in 16 in | 8 in 10 in 12 in 16 in | 1.5 mm | 3-point swing handle with key lock |
| 36 × 24 in | 8 in 10 in 12 in | 8 in 10 in 12 in | 2.0 mm | 3-point swing handle with key lock |
| 30 × 30 in | 8 in 10 in 12 in | 8 in 10 in 12 in | 1.5 mm | 3-point swing handle with key lock |
| 36 × 30 in | 8 in 10 in 12 in 16 in | 8 in 10 in 12 in 16 in | 2.0 mm | 3-point swing handle with key lock |
| 42 × 30 in | 10 in | 10 in | 2.0 mm | 3-point swing handle with key lock |
| 36 × 36 in | 12 in | 12 in | 2.0 mm | 3-point swing handle with key lock |
| 42 × 36 in | 8 in 12 in | 8 in 12 in | 2.0 mm | 3-point swing handle with key lock |
| 48 × 36 in | 8 in 10 in 12 in 16 in | 8 in 10 in 12 in 16 in | 2.0 mm | 3-point swing handle with key lock |
| 60 × 36 in | 12 in 16 in | 12 in 16 in | 2.0 mm | 3-point swing handle with key lock |
Each depth links to its product page: price, configuration (empty, IMD mini PC, panel PC door cutout), CAD and the size in detail.
The shallowest depth of each footprint in 304; every other depth and the 316L version are in the table above.

304 stainless wall-mount enclosure
6 × 4 × 4 in
2 DIN, tight84 mm usable2 W

304 stainless wall-mount enclosure
6 × 6 × 4 in
5 DIN, tight84 mm usable3 W

304 stainless wall-mount enclosure
8 × 6 × 4 in
5 DIN84 mm usable4 W

304 stainless wall-mount enclosure
8 × 8 × 4 in
8 DIN84 mm usable5 W

304 stainless wall-mount enclosure
10 × 8 × 4 in
8 DIN84 mm usable5 W

304 stainless wall-mount enclosure
12 × 10 × 6 in
11 DIN135 mm usable9 W

304 stainless wall-mount enclosure
12 × 12 × 6 in
14 DIN135 mm usable10 W

304 stainless wall-mount enclosure
14 × 12 × 6 in
14 DIN135 mm usable12 W

304 stainless wall-mount enclosure
16 × 12 × 6 in
28 DIN134 mm usable13 W

304 stainless wall-mount enclosure
16 × 14 × 6 in
30 DIN134 mm usable14 W

304 stainless wall-mount enclosure
16 × 16 × 6 in
36 DIN134 mm usable16 W

304 stainless wall-mount enclosure
16 × 20 × 6 in
40 DIN134 mm usable19 W

304 stainless wall-mount enclosure
20 × 16 × 6 in
36 DIN134 mm usable19 W

304 stainless wall-mount enclosure
24 × 16 × 8 in
54 DIN185 mm usable25 W

304 stainless wall-mount enclosure
20 × 20 × 6 in
38 DIN134 mm usable23 W

304 stainless wall-mount enclosure
20 × 24 × 8 in
48 DIN185 mm usable29 W

304 stainless wall-mount enclosure
24 × 20 × 6 in
57 DIN134 mm usable26 W

304 stainless wall-mount enclosure
24 × 24 × 6 in
72 DIN134 mm usable30 W

304 stainless wall-mount enclosure
30 × 20 × 8 in
76 DIN185 mm usable36 W

304 stainless wall-mount enclosure
24 × 30 × 8 in
99 DIN185 mm usable40 W

304 stainless wall-mount enclosure
30 × 24 × 8 in
96 DIN185 mm usable41 W

304 stainless wall-mount enclosure
36 × 24 × 8 in
120 DIN184 mm usable48 W

304 stainless wall-mount enclosure
30 × 30 × 8 in
132 DIN185 mm usable48 W

304 stainless wall-mount enclosure
36 × 30 × 8 in
165 DIN184 mm usable56 W

304 stainless wall-mount enclosure
42 × 30 × 10 in
155 DIN235 mm usable70 W

304 stainless wall-mount enclosure
36 × 36 × 12 in
210 DIN286 mm usable76 W

304 stainless wall-mount enclosure
42 × 36 × 8 in
200 DIN184 mm usable75 W

304 stainless wall-mount enclosure
48 × 36 × 8 in
240 DIN184 mm usable84 W

304 stainless wall-mount enclosure
60 × 36 × 12 in
320 DIN286 mm usable118 W
Guide
NEMA 4 vs 4X vs IP66
The hose and dust tests side by side, the salt-spray test behind the X and what it does not cover, IP69, and a quick way to choose.
Read the guideGuide
NEMA enclosure types
Types 1, 3R, 4, 4X, 6P and 12 side by side, the NEMA-to-IP table, and why an IP code is not a NEMA type.
Read the guideGuide
UL 50E, NEMA 250 and listing
Self-declared vs listed enclosures, what the NEC and OSHA ask for, UL 508A panels, field evaluation, and when you need a listed box.
Read the guideGuide
Cutouts, glands & HMI windows
Knockout and gland hole sizes, 22 and 30 mm operators, HMI cutout tolerances and panel thickness, windows, and what to send for a quote.
Read the guideNot a standard size?
Your size, material and cutouts, delivered in 10 business days.
Set width, height and depth, the material and the NEMA type in the enclosure builder, or send your drawing. From one piece, anywhere in the world. Counted from your order; for custom work, from your approval of the drawing.
Asked and answered
NEMA 4X enclosures: questions
Is NEMA 4X the same as IP66?
No. They are different tests from different standards. NEMA's comparison shows Types 4 and 4X meeting or exceeding IP66, but an IP66 enclosure is not automatically NEMA 4 or 4X: IP codes say nothing about corrosion, ice or gasket aging, and the NEMA hose test allows no water inside. The full comparison.
Do I need NEMA 4X, or is NEMA 4 enough?
Type 4 covers dust, rain and hose-directed water. Choose 4X when the enclosure will see washdown chemicals, salt air, de-icing salt, wastewater or chemical fumes: it adds the corrosion test. Our standard enclosures are stainless and rated 4X; a NEMA 4 enclosure in powder-coated carbon steel is a custom build.
Do these NEMA 4X enclosures carry a UL listing?
No. They are rated NEMA 4X / IP66 by the manufacturer and are not UL listed. If your inspector or specification requires a listed enclosure, read UL 50E, NEMA 250 and listing before you order.
Which depths can I get?
4, 6, 8, 10, 12, 16 in, depending on the footprint (table above). Usable depth from the mounting panel to the closed door runs from about 84 to 388 mm; each product page checks your deepest device against it.
Does a cutout or cable gland keep the 4X rating?
Only if every fitting carries at least the same type rating and is installed as its maker specifies: the assembled rating is limited by the weakest fitting. Place glands, operators and windows in the cutout designer and we cut them.