Short answer: Metri-Pack names a contact system, not a rating. A sealed 280 series pair serves an outdoor transmitter only as a complete assembly — wire seals matched to the cable's insulation diameter, a plug in every unused cavity and the latch fully engaged — with an IP code the datasheet prints for the mated condition. Where the transmitter maker gives you none of that, treat the connection as splash-proof and land the leads inside a NEMA 4X stainless junction box on terminal blocks.
What the Metri-Pack name does and does not tell you
Metri-Pack grew out of automotive harness practice, and the series number tracks the terminal blade width: a 280 series blade measures 2.8 mm, a 150 series blade 1.5 mm. Each series comes in sealed and unsealed versions. The sealed 280 series is the one meant for wet service; its own literature positions it for critical low-energy electronics and under-hood exposure. The unsealed 150 series is a dry-location connector and belongs indoors or inside a sealed box.
The family name alone tells you none of this. Two transmitters can both say Metri-Pack 280 and use different housings, terminals and seal kits. Before you compare transmitters, get from each supplier the exact part numbers for both halves — housing, terminal, wire seal, cavity plug and latch — plus the environmental rating and the condition it was tested in.
The same supplier family's Weather Pack sealed terminals show how deliberate the selection has to be: colour-coded wire seals chosen by wire size, red for 20 AWG thin-wall insulation and green for 18, 16 and 14 AWG. A seal is specified for a wire, never assumed.
The rating to specify: mated, sealed, and printed
IEC 60529 applies an IP code to a connector only when it is fully mated. The digit that matters outdoors is the second one: 4 is splashing water, 5 is jets from a 6.3 mm nozzle at 12.5 L/min, and 7 is temporary immersion at 1 m depth for 30 minutes. So IP67 printed on a connector datasheet promises the mated pair survives 30 minutes under 1 m of water; it says nothing about the open receptacle during a sensor swap. The full digit chart is in the site's IP rating guide.
Unmated, a connector carries no second-digit water protection unless the maker documents a rated cap for that exact cap and housing. The same mated-condition rule governs what an M12 or M8 mated pair keeps out, and the unmated state is what leaves an IP67 USB-C connector unprotected.
Never read a NEMA Type out of an IP code, and in US installations NEC 110.28 says an IP code does not replace an enclosure Type rating. Ask the supplier for three things in writing: the IP code, the mated condition, and the seal and plug parts the rating covers.
What a tropical outdoor site does to the pair
A tropical coastal site attacks the connection from two directions at once. Driven rain finds the back cover and the mating face. Humidity does the slower damage: in air at 28 C and 80% relative humidity, a plausible afternoon there, the dew point sits near 24 C, so a transmitter shell that cools 5 C overnight drips on the inside. Water that crosses any single boundary ends up in the lowest cavity of the housing, where it wicks along the wire.
Plan against the failure you cannot see at commissioning: a dry-looking assembly that corrodes over months. A stable 4–20 mA reading on a dry afternoon proves nothing about the next wet season.
The four sealing boundaries
Every path from outside to the contacts crosses one of four boundaries, and each needs its own part:
| Boundary | Part that seals it | What it must match |
|---|---|---|
| Housing mating face | O-ring or gasketed interface on the sealed 280 housings | Both housing part numbers, latch fully engaged |
| Each wire entry | Wire seal in the rear cavity | The conductor's insulation diameter, not the gauge alone |
| Unused cavities | Cavity plug of the same seal series | One plug per empty position; sealed housings are documented with unused female cavities sealed this way |
| Transmitter body | Connector-to-body seal on the sensor | The transmitter's own datasheet, not the connector's |
A terminal can click into a cavity while its seal leaves the wire entry open; retention and sealing are separate parts, chosen separately. Order cavity plugs even for housings you fill completely, because harnesses get reworked.
Worked example: will the wire seal fit your cable
Take a 2-cavity sealed 280 housing carrying one pin of a 4–20 mA loop. One documented 280 series wire seal covers 1.86 to 2.4 mm of insulation diameter. Compare two candidate 18 AWG leads:
- Thin-wall 18 AWG with 2.1 mm insulation: inside the range, the seal compresses and seals the entry.
- General-purpose 18 AWG with 2.8 mm insulation: 2.8 − 2.4 = 0.4 mm oversize. The seal will not seat, and the entry stays open to wicking.
The fix is to change the cable, never to force the assembly together. Then count the plugs: 2 cavities minus 1 pin leaves 1 cavity plug. Skip it and you have reopened the only hole in the assembly. Measure insulation with calipers before ordering seals; gauge alone is not enough information to pick the part.
When to land the leads in an enclosure
If the transmitter datasheet prints no mated IP code, decide by exposure:
- Sheltered from rain and spray (under a canopy, inside a process building): a sealed 280 assembly works, with a drip loop so water runs off below the pair.
- Exposed to rain: keep the field connector only when the supplier states the mated rating in writing; otherwise box it.
- Washdown, hose-down or standing water: box it every time. The gland seals on the jacket and the terminals stay dry inside a manufacturer-rated NEMA 4X / IP66 box, which is not UL listed and not immersion-rated.
Boxing it means a wall-mount stainless junction box with factory cutouts on your drawing, so each hole arrives deburred and where you marked it. Pair each gland to the cable jacket — for a 6.5 mm jacket, a gland clamping 5 to 9 mm is a typical example range — and drop the cable into a 50 mm drip loop below the entry. Land the loop on terminal blocks the way the terminal-block interface layout sets out, and keep clear depth under the blocks for the conduit entries as in the junction box height guide. The smallest wall-mount sizes live in the stainless junction box section.
What to put on the order
| Order line | What to write |
|---|---|
| Transmitter | Connector option with exact housing, terminal and seal part numbers, or flying leads |
| Seals and plugs | Insulation diameter range in mm covering your cable; one plug per unused cavity |
| Rating evidence | Printed mated IP code and the parts it covers |
| Enclosure | 304 or 316L wall-mount box, manufacturer-rated NEMA 4X / IP66, cutouts per drawing |
| Delivery | Delivered in 10 business days — from the order, or from drawing approval for custom cutouts |
So the decision reads: printed mated rating with matched seals and plugs — run the field connector and keep the drip loop. Sealed 280 parts with no printed rating — shelter it or box it. Unsealed 150 series — indoors only. Washdown, hose-down or standing water — stainless junction box with terminal blocks, every time.
Catalog dimensions to compare
Compare these catalog dimensions with your component layout. Open each enclosure for its rating, material and usable space, then check those specifications against your application.
| Enclosure | Material | Outside H x W x D / display | Rating |
|---|---|---|---|
| 16 × 12 × 8 in | 304 stainless | 16 x 12 x 8 in | Rated NEMA 4X / IP66 by the manufacturer; not UL listed |
| 20 × 16 × 8 in | 304 stainless | 20 x 16 x 8 in | Rated NEMA 4X / IP66 by the manufacturer; not UL listed |
| 24 × 20 × 8 in | 304 stainless | 24 x 20 x 8 in | Rated NEMA 4X / IP66 by the manufacturer; not UL listed |
| 6 × 6 × 4 in | 304 stainless | 6 x 6 x 4 in | Rated NEMA 4X / IP66 by the manufacturer; not UL listed |
Questions
Does a Metri-Pack connector have an IP rating?
The family name carries none. A sealed 280 series assembly with matched wire seals, cavity plugs and an engaged latch is built for wet mated service, and where a datasheet prints IP67 it covers the mated pair at 1 m of water for 30 min. Get the code, the condition and the seal part list from the transmitter supplier in writing before you order the harness.
Is the connector waterproof while unplugged?
No. IEC 60529 codes apply only to the fully mated pair, so an open receptacle has no second-digit water protection unless the maker documents a rated cap for that exact cap and housing. Plan sensor swaps for dry weather, or land the loop on terminal blocks inside a NEMA 4X junction box so the wet-side connection never opens.
What wire seal fits 18 AWG in a 280 series connector?
One documented 280 series seal covers 1.86 to 2.4 mm of insulation diameter, so a thin-wall 18 AWG lead at about 2.1 mm seals and a general-purpose build at 2.8 mm does not. Measure the insulation with calipers, not just the gauge. The related Weather Pack convention colours seals by wire: green for 18, 16 and 14 AWG thin-wall.
Can I leave a Metri-Pack transmitter outdoors under a cover?
Yes, when the assembly is fully sealed with a printed mated rating and the cover keeps off driven rain; add a drip loop below the connection. With no printed rating, treat the pair as splash-proof and land the leads in a stainless wall-mount box, manufacturer-rated NEMA 4X / IP66, with terminal blocks for the 4-20 mA loop.
How do I order the enclosure cutouts for the transmitter glands?
Use the cutout designer or send a dimensioned drawing: mark each gland position, its hole diameter and the drip-loop side, and choose 304 or 316L. Custom enclosures are delivered in 10 business days counted from your approval of the drawing, and the cutouts arrive deburred so the gland gaskets seat flat.