Short answer: read an IP67 USB-C receptacle as IP67 mated until its datasheet states the unmated state. The digit 7 test in IEC 60529 holds the sample completely under water for at least 30 min, with its highest point at least 1 m below the surface, and the result attaches to the assembly in the tested condition. For most panel-mount USB-C receptacles that condition is plug inserted and flange gasketed to the panel. Unplug the cable and the cavity over the contacts stands open, with nothing in the rating to cover it. A port that spends time open on an enclosure face needs one of three things: a connector documented for the unmated state, a cap with its own stated IP67, or a latching cover. The flange gasket does its work in every case, because that gasket is what keeps water out of the enclosure itself.
What the IP67 claim on the bag actually covers
The code carries two digits, and both belong to one tested assembly. The 6 means dust-tight: the sample rides out the dust test with no ingress at all. The 7 means temporary immersion: the sample goes completely under and stays at least 30 min, its lowest point at least 0.15 m below the surface and its highest point at least 1 m. What the code never prints is the condition. IEC 60529 tests whatever configuration the maker submits, so every claim in a catalog is really "IP67 as tested". On a panel-mount USB-C receptacle the submitted configuration is nearly always the pair: plug inserted, flange compressed onto the panel through its own gasket. Two seals carry the number — the plug-to-receptacle interface and the flange-to-panel gasket. Pull the plug and one of the two is gone.
That makes the connector's IP67 and the enclosure's rating separate claims about separate assemblies. The port adds a third assembly — connector, gasket, panel — and the datasheet, not the digits, decides how it behaves open. In US installations, NEC 110.28 draws the same line for the box: an IP code does not replace the enclosure type number the panel carries. The full digit-by-digit code, first digit to second, sits in the IP rating chart guide.
What the digit 7 test does, and what it never does
The digit 7 run is static: submerge, hold 30 min, lift, inspect. No jet plays on the sample from any angle, and the water never moves. The jet tests are different digits with their own figures — IEC 60529 drives digit 5 through a 6.3 mm nozzle at 12.5 L/min and digit 6 through a 12.5 mm nozzle at 100 L/min — and a digit 7 result says nothing about the part under either stream. The IP65 vs IP66 jet test comparison puts numbers on that difference. A receptacle sealed to IP67 mated can still take water through the open port under a washdown hose, because a hose is a jet problem the immersion sample never met.
Digit 7 is "temporary immersion" on purpose. Continuous immersion is digit 8, with the depth and duration the maker and the user agree and the datasheet states. The two digits also stay silent on corrosion, sunlight, temperature cycling and oil; those choices belong to the housing material and the gasket compound. The IP66 or IP67 versus outdoor rated comparison works through the rest of the gap between a lab tank and a wall outdoors.
Pressure on a mated USB-C seal at the 1 m test depth
Inputs: test depth 1 m to the highest point of the sample, from the digit 7 condition in IEC 60529; fresh water density 1000 kg/m³; gravitational acceleration 9.81 m/s². Rule: still water presses with p = ρ × g × h, the weight of the water column above each square metre of seal.
The arithmetic: p = 1000 kg/m³ × 9.81 m/s² × 1 m = 9810 Pa = 9.8 kPa. In US units, 9810 Pa ÷ 6895 Pa/psi = 1.42 psi.
So the whole IP67 claim rests on a seal that holds back about 9.8 kPa [1.4 psi] of still water for 30 min. Depth is linear: every extra metre adds another 9.8 kPa, so a maker's IP68 claim at 2 m asks the same seal for about 19.6 kPa [2.8 psi], and a 5 m claim asks 49 kPa [7.1 psi]. The pressure is the easy half of the decision. Whether the seal exists at all — mated, capped or open — comes from the condition wording, and that is where you commit.
Reading the datasheet's condition column
Catalog listings rarely print the condition; the datasheet does. Three wordings cover nearly everything on the shelf:
| Datasheet wording | What carries the seal | Port open |
|---|---|---|
| IP67, mated | Plug interface plus flange gasket | Unsealed; water sits in the contact cavity |
| IP67, mated and unmated | The receptacle's own internal seal | Rated open, within the stated test |
| IP67 unmated, cap fitted | Cap seal plus flange gasket | Rated only while the cap is on and latched |
An IPX7 mark with no condition line is the trap; treat it as mated-only. The sealing mechanism tells the same story from the product photos: a plain through-hole receptacle with a rear gasket seals the panel and nothing else, while parts with an integrated spring flap, or a sealing plug shipped in the bag, are the ones that can claim an open state.
Read the cycle figure while you are there. The USB Type-C cable and connector specification sets the connector family at 10,000 mating cycles minimum, proven at 500 ± 50 cycles per hour, and the IP line stands separately from it: some makers state the rating for a new part only. The sealed families are specified for -40 to +85 C operation and keep the standard USB-C figures, up to 100 W of power and 10 Gbps of data, so sealing costs the port nothing in function.
The mated-versus-unmated logic runs through every connector family, not just USB-C: the mated vs unmated IP-rating explainer covers round connectors, and what the mated pair keeps on M12 and M8 applies the same rule to the sensor-size families.
What it changes on an enclosure face
Put the port on a housing and you are managing two seals and one hole. The flange gasket is the one that protects the enclosure: seated evenly around the cutout, it keeps water out of the box whether or not a plug is fitted. Give it the opening it was tested with — the USB Type-C receptacle cutout dimensions article has the rectangular size — and the face-seal squeeze logic the O-ring compression article works through for gasketed doors.
The port mouth is the connector's business, and it becomes the leak path the moment the plug comes off. An open USB-C cavity holds water by surface tension, wets the contacts and starts corrosion long before the next plug goes in. Our stainless wall-mount boxes are rated NEMA 4X / IP66 by the manufacturer; not UL listed, and the HMI housings keep an IP65-type front seal with the display installed. Either face holds its rating only when the accessory seated in it is sealed with its tested gasket — a plain hole or a loose-fitting receptacle drags the whole assembly down with it. The waterproof USB and ethernet ports how-to walks the build: gasket seat, fastening, cover hardware.
Housing size does not change the rule. On the 10.1 in panel PC housing and the 15.6 in one, the service port lands on the face just the same, so the same two-seal logic and the same cap discipline apply.
What to specify, case by case
| Duty at the port | Order this | What holds |
|---|---|---|
| Cable stays plugged in during use | IP67-mated receptacle, panel gasket, dust cap for idle hours under a roof | IP67 while mated; face sealed at all times |
| Port must survive hose-down open | Connector documented IP67 or IP68 unmated, or a flip or screw cap whose datasheet states IP67 for the capped state, on a lanyard | IP67 open only while the cap is latched |
| Rare debug port on a dry indoor wall | IP67-mated receptacle plus a plain dust cap | Face rating intact; open state covered by the cap's dust fit only |
| Washdown HMI face | Take USB through a sealed gland to an internal hub, so the face carries no connector | Housing rating untouched |
Put the condition wording on the drawing. Lay the cutout, the cap clearance and the latch swing out together in the cutout designer — a flip cover needs its swing arc, a screw cap needs wrench room, and a lanyard needs an anchor point — and note the connector's exact datasheet line, "IP67, mated" or "IP67 unmated, cap fitted", so the cap ships with the box instead of being hunted down later. The receptacle, its gasket and its cap belong on one line of the order.
The decision in one pass: a USB-C connector's IP67 is a claim about a state, not a promise about the port. Mated-only parts take a cap or a latching cover before they face water open. Parts documented for the unmated state carry it in their own datasheet line, cycle life included. And in every case the flange gasket, seated on its tested cutout, is what keeps the enclosure's face sealed — 1 m, 30 min, 9.8 kPa is the whole promise, and the cap or the plug is what makes it true.
Enclosures in this article
| Enclosure | Material | Outside H x W x D / display | Rating |
|---|---|---|---|
| 10.1" HMI enclosure | 304 stainless | 8.72 x 12.66 x 3.48 in | IP65-type front seal with the display installed, manufacturer rated; not UL listed |
| 15.6" HMI enclosure | 304 stainless | 11.69 x 17.64 x 4.13 in | IP65-type front seal with the display installed, manufacturer rated; not UL listed |
Questions
Is an IP67 USB-C connector waterproof when unmated?
Only when its datasheet says so. Most panel-mount receptacles are rated IP67 mated: plug inserted, flange gasketed to the panel. Open, the contact cavity is unsealed. For a port that lives open, order a part documented IP67 unmated or a cap whose datasheet states the capped state; the IEC 60529 digit 7 test itself is 1 m immersion for 30 min, run in whichever condition the maker declared.
How much water pressure does the IP67 test put on the seal?
At the 1 m test depth, still water presses at about 9.8 kPa [1.4 psi], held for at least 30 min. Depth is linear, so each extra metre adds about 9.8 kPa: a maker's IP68 claim at 2 m loads the same seal with about 19.6 kPa. The number is small; whether the seal exists mated, capped or open decides everything.
Does a USB-C port keep my enclosure's NEMA 4X / IP66 rating?
The face rating and the port rating are separate claims. The receptacle's flange gasket, seated on its tested cutout, is what keeps the housing sealed; our stainless wall-mount boxes are rated NEMA 4X / IP66 by the manufacturer; not UL listed. An IP67 mark on the connector does not replace the enclosure type number either: NEC 110.28 keeps the two apart in US installations.
Can I hose down a panel with an open IP67 USB-C port?
No. Digit 7 is still immersion, never a jet: IEC 60529 runs digit 5 through a 6.3 mm nozzle at 12.5 L/min and digit 6 through a 12.5 mm nozzle at 100 L/min, and an IP67 part carries no jet figure at all. An open port under a hose is unsealed from every direction, so cap it or cover it before the washdown starts.
How many mating cycles does a sealed USB-C port survive?
The USB Type-C specification sets the connector family at 10,000 cycles minimum, tested at 500 ± 50 cycles per hour. That figure covers the contacts; the IP rating is a separate datasheet line, and some makers state it for a new part only, so compare the seal figure with the duty before putting the port on a lid that opens all day.