Cable gland selection for an IP67 enclosure with sensor entries

Fit one IP68-rated compression gland per sensor cable, sized so the cable's measured OD — 6.0 mm in the worked example — sits mid-range in the gland's clamping range, entered through the bottom wall the way the enclosure maker documents. IP67 itself is a 30-minute soak under 1 m [3.3 ft] of water; a gland tested at 1 bar [14.5 psi] clears that with a tenfold pressure margin.

NEMA4 Enclosure engineering team · Published November 23, 2026 · 9 min read

Short answer: fit one IP68-rated compression gland per sensor cable, sized so the cable's measured outer diameter sits mid-range in the gland's clamping range, entered through the bottom wall and installed the way the enclosure maker documents. IP67 itself is a 30-minute soak with the water surface 1 m [3.3 ft] above the box, so every part below the box's rating needs numbers of its own. A gland datasheet that prints 1 bar [14.5 psi] for 30 minutes clears the IP67 condition at the lowest entry with roughly a tenfold pressure margin. Here is the gland to pick, the hole to cut, the tightening sequence and the soak that proves it.

What cable gland do you need for an IP67 enclosure?

You need a compression gland rated IP68 with a stated test pressure and duration — one datasheet prints 1 bar [14.5 psi] for 30 minutes — whose clamping range lands on the cable's measured outer diameter, installed exactly as the enclosure maker documents.

An IP code printed on a gland describes the gland alone, tested as a component. The finished assembly is only as sealed as its weakest path: the gland, the hole, the washer under the locknut and the wall around the hole. Treat the datasheet as the part's spec. It states the clamping range, the hole diameter for the thread, the tightening torque and the pressure and time behind the IP68 mark. One polyamide range carries IP68 at 5 bar [72.5 psi]; another prints IP68 at 1 bar [14.5 psi] for 30 minutes. Buy on those two numbers, because IP68 on its own names no depth and no duration.

If the vocabulary is new, start with what a cable gland does for an enclosure, then come back for the sizing. The gland is three parts in one: a compression seal on the cable, a threaded entry into the wall, and a strain relief that keeps terminal pull away from the seal.

What does the IP67 test actually immerse?

IEC 60529 tests the second digit 7 by keeping the enclosure under water for 30 minutes with the surface at least 1 m [3.3 ft] above the box's bottom, or 0.15 m [6 in] above its top — a temporary soak, not continuous immersion.

The digit 7 expects no water inside afterwards, entries included. Two consequences follow for a sensor build. Every penetration is underwater, and the lowest one sees the full head: 1000 kg/m³ × 9.81 m/s² × 1 m = 9.8 kPa, about 0.098 bar [1.4 psi] — a tenth of the 1 bar gland test above. The digit 8 is the continuous-immersion digit, defined by depth and duration agreed between maker and user, which is why an IP68 gland must print its own numbers. In US installations, NEC 110.28 says an IP code does not stand in for an enclosure Type rating, so a drawing that calls out IP67 carries the box's Type number as well. The IP code chart lays out what each digit of both systems tests.

What tools and parts do you need for an IP67 gland install?

You need four things on the bench: the gland's datasheet with its clamping range and hole size, a caliper that reads to 0.1 mm [0.004 in], the sealing washers and locknuts the glands ship with, and a tank deep enough to hold the box under water for the full 30 minutes at the test depth.

Lay the rest out once and the install goes fast:

  • One gland per cable, IP68-rated with its pressure and time printed, clamping range spanning the measured cable OD
  • Thread seal tape or the gland maker's thread sealant, for metal walls
  • The drill sizes the datasheets print, plus a deburring tool
  • Dry paper tissue and a depth marker for the 30-minute proof soak

Buy the glands with the cables or their datasheets in hand. A gland ordered on thread size alone is the most common way a project loses a week waiting for the right clamp.

How do you match the gland's clamping range to the cable?

Measure each cable over its jacket with the caliper and pick a gland whose range puts the number mid-range: a cable measuring 6.0 mm [0.24 in] fits a 4-7 mm range with about 1 mm of margin on each side.

Datasheets print the range in millimetres, and the cable's actual jacket diameter — not the largest cable the gland can swallow — is what has to land inside it. A PG7-size gland clamps 3-6.5 mm [0.12-0.26 in]; the next size prints 4-7 mm [0.16-0.28 in]; a large power gland spans 20-32 mm [0.79-1.26 in]. The seal grips the jacket's round section, so keep stripping, solder sleeves and heat-shrink beyond the internal seal, on the dry side of the wall.

Gland on the datasheet Clamping range printed Fits
PG7-size gland 3-6.5 mm [0.12-0.26 in] thin round sensor leads
Mid-size compression gland 4-7 mm [0.16-0.28 in] jacketed sensor cable, the 6.0 mm example
Large power gland 20-32 mm [0.79-1.26 in] trunk and power cable

Those ranges are examples gland datasheets print; the datasheet for the gland you buy decides. Matching the seal to the cable is the whole game — the clamp that lands mid-range also holds through temperature swings. One gland per cable is the rule, and the cases where two cables share one gland all start with a gland built for it. Flat sensor ribbon is its own entry problem, because a round range cannot close on a flat section; that cable wants a gland block cut for its cross-section.

Where do the gland holes go on an IP67 box?

Enter through the bottom wall, on flat metal, with every hole at least 15 mm [0.6 in] clear of corners, wall joints and the door gasket — glands-down keeps water pressing the seals closed and lets drips run out between soaks.

Worked example — four sensor cables into a bottom wall 160 mm [6.3 in] wide; swap in your own wall width and cable count. Set gland centers 30 mm [1.2 in] apart, enough room for two locknut washers and a spanner between neighbors. Four centers span 3 × 30 mm = 90 mm [3.5 in]. Centered on the wall, the first hole lands at (160 − 90) / 2 = 35 mm [1.4 in] from the side wall and the last at the same distance, so every hole clears a 15 mm [0.6 in] corner margin with 20 mm to spare. Mark, center-punch, drill to the datasheet's hole diameter and deburr both faces.

The glands-down orientation earns its place on any box that lives outdoors or under water, and it is why the top stays solid. A wall also takes a limited number of penetrations before strength and layout suffer; the penetration-spacing guide works that count before you commit the drill.

How do you install the gland so it seals under water?

Pass the gland through the hole from the outside with its sealing washer under the body, capture it with the locknut and washer inside, and tighten to the datasheet's torque while a spanner holds the body still.

  1. Check the cable against the clamping range with the jacket on: the 6.0 mm [0.24 in] example cable sits inside 4-7 mm with about 1 mm of margin each side.
  2. Drill the datasheet's hole size and deburr both faces; a burr or chip under the washer stands the seal off the wall.
  3. On a metal wall, wrap the gland thread with 2-3 turns of seal tape or run the maker's thread sealant, so the thread itself is never the leak path.
  4. Slide the sealing washer onto the gland body and pass it through the hole from outside.
  5. Fit the locknut with its washer flat against the inside wall. Hold the body still with a spanner and tighten to the datasheet's torque; where the datasheet prints none, hand-tight plus a quarter turn seats the seal without crushing it.
  6. Keep the cable straight for 50 mm [2 in] past the gland and fit a strain clamp, so pull at the terminals never reaches the seal.
  7. Repeat one gland per cable until every entry is done.

A field-drilled entry keeps its place in the rating only as a documented entry: the gland maker's component rating plus the enclosure maker's instructions for that rating. Installing a gland without losing the rating walks the sequence again with the failure points called out, and the guide on what drilling does to a rating covers the wall itself. Entries we cut arrive at the approved positions, deburred, so install day is fitting and tightening rather than rework.

How do you prove the entry seals before deployment?

Run the rating's own numbers before deployment: sink the assembled, unpowered box with the water surface at the IP67 test height above its bottom for the full 30 minutes, a dry tissue inside, then dry the shell and open it — the tissue turns a slow weep into an obvious damp patch.

Close the lid to its normal torque and lower the box in, entries down. Dry the outside before you open it, so surface water cannot fall in and fake a failure. A damp patch on the tissue under a gland points at the washer or the hole; a damp ring on the jacket points at the clamp; water at the threads points at skipped sealant. A box that passes the soak but fogs up a week later has condensation, not a leak, and that fix is air management rather than glands. Dry the interior fully and check for absence of voltage before you close it up and re-power.

Which mistakes cost an IP67 box its rating?

The failures that turn up again and again in the soak tank: push-in grommets, two cables in one gland, seals clamped on stripped jackets, oversize or corner-cut holes, and glands marked IP68 with no depth or duration behind them.

Each has a direct replacement:

  • Push-in grommets. Friction holds splash water, and full test head finds the skirt in the first minutes; use a compression gland sized to the cable.
  • Two cables in a single-cable gland. The channel between the jackets stays open at depth; use two glands or a multi-cable gland.
  • A seal clamped on stripped insulation or heat-shrink. The jacket's round section is the sealing surface; strip on the dry side, beyond the gland.
  • Oversize or corner-cut holes. An oversize hole leaves the washer unsupported and a corner hole leaves it half off the wall; drill to the datasheet size and keep 15 mm [0.6 in] from corners.
  • IP68 with no printed numbers. Depth and duration are the content of the mark; buy a gland that states its pressure and time.
  • Sensor leads under the smallest clamp. Stretching a gland below its 3 mm [0.12 in] minimum distorts the seal; use a potted penetrator on underwater entries too fine for any gland's clamp.

What do you put on the order for a stainless IP67 enclosure?

For a stainless build, send the cable count and each measured OD, the entry positions, the depth and duration of the real immersion duty, and the fluid, and we cut every gland hole at the factory to the approved drawing.

Ratings are manufacturer ratings: our 304 and 316L stainless boxes are rated NEMA 4X / IP66 by the manufacturer; not UL listed. IP66 is a powerful-jet rating rather than an immersion one, so an immersion duty goes through a custom review and the drawing confirms what the finished assembly carries. Custom stainless enclosures with factory cutouts take the gland holes from that drawing, deburred and positioned, and the box is delivered in 10 business days from drawing approval. For splash-duty sensor boxes in the standard range, start from the stainless junction boxes page and add the cutouts you need there.

Questions

Can two sensor cables share one cable gland?

Only when the gland is made for multi-cable entry with each cable's diameter matched to its own bore. A single-cable gland with a 4-7 mm [0.16-0.28 in] range compresses around one round jacket; two cables leave an open channel between them that the soak test finds in minutes. Fit two glands, or a documented multi-cable seal.

Does a push-in grommet hold IP67 underwater?

A grommet's skirt seals by friction, which holds splash and hose water; at the test depth of 1 m [3.3 ft] the 30-minute soak finds the gap around it. Use a compression gland sized to the cable's measured OD, or a potted penetrator for leads under the 3 mm [0.12 in] minimum that the smallest glands clamp.

Does an IP68 gland turn a NEMA 4X box into an immersion-rated box?

The finished assembly carries the lowest capability of its parts. A box rated NEMA 4X / IP66 by the manufacturer is proved with powerful jets, not immersion, and a 1 bar [14.5 psi] gland does not change the wall's own test. Immersion duty needs the box maker's depth and duration rating; on our stainless boxes that is a custom design review.

Where does an antenna go on a stainless IP67 enclosure?

Outside the wall. Stainless blocks most of a 2.4 GHz signal, so bring the feed out through a bulkhead antenna connector rated IP68 at the same depth and duration as the glands, with the antenna and its seal on the outside. Keep the connector's inside gasket flat against the wall, same as a gland washer.

Application requirements

Specify the immersion conditions before choosing a housing

Our standard NEMA 4X / IP66 boxes are for hose-directed water, not underwater use. For a custom immersion design, send the maximum depth, duration, water chemistry, temperature range and cable-entry drawing. We will confirm feasibility and the rating basis before you order.