Blank DIN rail mount enclosures for custom modules

The form factor is the DIN 43880 modular housing: 17.5 mm of rail width per module, a 90 mm-tall body, sold blank in 2, 4, 6 and 9 module widths with pluggable terminals and a clear window cap. Your PCB snaps onto the rail beside the breakers, terminals stay enclosed and only the LEDs show; past 157.5 mm of face, about 2 W of heat, or any water, move the build into a small stainless junction box.

NEMA4 Enclosure engineering team · Published November 13, 2026 · 6 min read

Short answer: the form factor is a blank modular DIN rail housing built to DIN 43880, and you order it by module count. One module (1M) is 17.5 mm [0.69 in] of rail width, the body stands 90 mm [3.54 in] tall, and blank families ship in 2, 4, 6 and 9 module widths. Your PCB snaps onto the 35 mm top-hat rail beside the breakers, field wires land on pluggable terminals inside the body, and a clear window cap leaves only the LEDs showing. Past 157.5 mm [6.2 in] of face width, about 2 W of heat, or the first drop of water, a small stainless junction box with the rail inside wins instead.

What is this DIN rail form factor called?

It is a modular DIN rail housing, also called a unit-mount housing, and DIN 43880 sets its geometry: 1M = 17.5 mm [0.69 in] of width, a 90 mm [3.54 in] body height, and face widths stated in whole modules. The standard states width in M units so anything you build lines up with the breaker row beside it. Modular breakers put one pole plus neutral into 17.6 mm [0.69 in] at up to 40 A, which tells you the pitch is a power format, not a signal-only one.

A one-module blank body measures roughly 90 x 17.5 x 58 mm [3.54 x 0.69 x 2.28 in] — height, width, depth. The flame-retardant families come in 2, 4, 6 and 9 module widths, clip onto the 35 mm rail, and one documented range gives every size two mounting positions. Some ranges add a 9 mm [0.35 in] slim pitch for signal-only boards, and some are snap-fit sections you assemble yourself. For the board-level side of this, read about DIN rail PCB enclosures inside sealed cabinets.

How many modules wide should your housing be?

Set the width from the board footprint and the terminal count: 2M gives 35 mm [1.38 in] of face, 4M gives 70 mm [2.76 in], 6M gives 105 mm [4.13 in] and 9M gives 157.5 mm [6.2 in], with the body always 90 mm [3.54 in] tall.

Modules Face width What typically fits
1M 17.5 mm [0.69 in] One breaker-width channel, a slim timer
2M 35 mm [1.38 in] Small signal board, four to eight points
4M 70 mm [2.76 in] IO module with pluggable terminals
6M 105 mm [4.13 in] Board plus a small internal power supply
9M 157.5 mm [6.2 in] Multi-board assembly, metering front

Width costs nothing in the other two dimensions: all five rows share the 90 mm height and about 58 mm [2.28 in] of depth. Buy the width your terminal row needs and leave the rest of the rail for other devices.

How deep is the housing, and what cabinet depth does it need?

Plan on 58 mm [2.28 in] of body depth plus wiring space: in a 4 in-deep stainless box with 3.91 in [99 mm] of interior depth, the module face sits about 41 mm [1.6 in] clear of the door. That 41 mm comes straight from 99 - 58, and it has to hold the door, the dress and any duct.

The whole-row math works the same way. An 8 x 8 x 4 in box offers 7.91 in [200.9 mm] of interior width, and 200.9 / 17.5 = 11.5, so 11 modules fit; a 12th needs 210 mm and there are only 201. The article on minimum enclosure depth for DIN rail devices runs this for standard devices, and the backplate and DIN rail layout guide covers rail spacing and wire duct around them.

How do the wires get in while the terminals stay covered?

Order the body with blank end caps, drill your own entries in a cap or the underside, and land every field wire on pluggable terminal blocks that pull off the front — the detachable-terminal construction these ranges ship with. The body walls stay solid, so your entries live only in the caps you control, and the terminal row stays behind the module face exactly like an RCD's.

Snap-fit ranges let you widen the body later without swapping the whole housing. Count points before you order blocks — counting terminal points, not blocks — then pick the clamp from the spring clamp vs screw clamp comparison for your vibration and wire sizes. When spares come up, matching pluggable terminal blocks matters: pitch and current rating travel with the block, not the housing.

IP20 or IP40 for the terminals: which do you order?

Order IP40 finger-safe covers wherever the cabinet door gets opened while circuits are live; IP20 is enough inside a closed cabinet, and under IEC 60529 the difference is the probe — a 12.5 mm [0.5 in] finger versus a 1 mm [0.04 in] wire. Both carry 0 as the second digit, meaning no water protection at all, which is why a modular housing lives inside a cabinet and never stands in for one.

The finger-safe covers clip over the terminal row without costing you a module of width. They are worth the small step up in any panel that gets worked on hot, because the 1 mm probe test is also roughly the test a stray screwdriver shaft passes.

Can the LEDs show with the cabinet cover closed?

Yes — swap the solid lid for a clear window cap, and the LEDs read through it the way an RCD's flag reads through a consumer-unit cover: body closed, terminals inside, light out. Window caps are catalogue options in the same UL94 V-0 polycarbonate as the body, so the flame class stays consistent across the whole module.

Put the indicator side of your board toward the window when you lay it out, and check the cap clears your tallest component. For a board whose whole job is being seen, the article on transparent enclosures for boards with visible LEDs covers the window-material trade-offs.

When does the module belong in a stainless box instead?

Move the build out of the plastic body once any of three limits bites: face width past 157.5 mm [6.2 in], dissipation past about 2 W, or water anywhere near the installation. The heat limit comes straight from the body's surface. A 4M body (70 x 90 x 58 mm) exposes about 0.031 m² of surface, and at k = 3.5 W/m²K for plastic that sheds 3.5 x 0.031 = 0.11 W/K. Two watts inside lifts the body 2 / 0.11 = 18 C above cabinet air, and four watts lifts it 37 C. Run the same sum for your width before committing a power-hungry board.

The stainless route keeps your DIN rail and adds the enclosure around it. An 8 x 8 x 4 in 316L junction box carries the same 11-module row at 4 in of depth, and a 12 x 12 x 6 in 316L box carries 17 modules (11.91 in = 302 mm; 302 / 17.5 = 17.3) with base space for glands. When environment rather than width drives the choice, one module's electronics fit a 6 x 6 x 4 in 304 box. These boxes are rated NEMA 4X / IP66 by the manufacturer; not UL listed. The stainless junction box range lists panel, DIN capacity and depth for each size, and custom stainless enclosures build your cutout drawing for window and gland holes.

What goes on the order?

For the housing route, one line covers it: 4M blank modular housing, 17.5 mm pitch, 90 x 70 x 58 mm, pluggable screw terminals, two blank end caps, IP40 covers, clear window cap.

Line item Modular housing route Stainless box route
Format DIN 43880 body, 35 mm rail clip Wall-mount junction box, rail inside
Width or size 2M to 9M (35–157.5 mm) 6 x 6 x 4 in up to 12 x 12 x 6 in
Terminals Pluggable, screw or spring clamp Terminal blocks on the backplate rail
Protection IP20 body, IP40 finger-safe covers Rated NEMA 4X / IP66 by the manufacturer; not UL listed
LED view Clear window cap Door or window cut on a custom build
Environment Dry interior cabinets Washdown, outdoor, glanded cable

Decide by case. A dry indoor cabinet, up to 157.5 mm of face and about 2 W of dissipation: buy the modular housing. The same electronics facing washdown, weather or glanded cable: buy the stainless box and put the rail inside it. A board too wide for 9M or running its own hot supply: same answer, the stainless box. Custom work is delivered in 10 business days, counted from your approval of the drawing.

Enclosures in this article

EnclosureMaterialOutside H x W x D / displayRating
8 × 8 × 4 in316L stainless8 x 8 x 4 inRated NEMA 4X / IP66 by the manufacturer; not UL listed
12 × 12 × 6 in316L stainless12 x 12 x 6 inRated NEMA 4X / IP66 by the manufacturer; not UL listed
6 × 6 × 4 in304 stainless6 x 6 x 4 inRated NEMA 4X / IP66 by the manufacturer; not UL listed

Questions

How much current can one 17.5 mm module width carry?

Breaker practice puts one pole plus neutral into a 17.6 mm module at up to 40 A, so the width itself supports breaker-level current. Your module's real limit is set by the pluggable terminal blocks you fit and by the PCB traces between them. Treat 40 A as the ceiling the format reaches, not a rating your board inherits.

Do modular DIN housings come in flame-retardant plastic?

Yes. The documented families are moulded in polycarbonate or ABS carrying a UL94 V-0 flame class, and some ranges are snap-fit sections you assemble into the width you need. Keep any plastic you add inside a control cabinet at that flame class; unmarked hobby boxes stay outside the panel.

What does 1M mean on a DIN housing drawing?

It is the DIN 43880 module unit: 1M equals 17.5 mm [0.69 in] of rail width. A 6M body is therefore 6 x 17.5 = 105 mm [4.13 in] wide, and a 9M body is 157.5 mm [6.2 in]. Datasheets state width in M so your housing lines up with the breaker pitch in the same row.

Can you join two modular housings into one wider unit?

Yes. Snap-fit modular ranges assemble from sections, and two 4M bodies side by side give 140 mm [5.5 in] of face at the same 90 mm height and 58 mm depth, at the cost of a visible joint and two extra end caps. Beyond that width, a stainless box with the rail inside is the cleaner build.

Will a plastic modular housing survive outdoors?

No. These are interior parts carrying IP20 or IP40 with a 0 as the water digit, which means no water protection at all. Outdoor or washdown duty goes to a stainless enclosure rated NEMA 4X / IP66 by the manufacturer, not UL listed — for one module's worth of electronics, a 6 x 6 x 4 in box with the rail inside.

Checklist before you order

Specify it once, built to your drawing

  • Environment and NEMA type: Type 1, Type 3R, Type 4, Type 4X, Type 6P, Type 12, Type 13 (manufacturer ratings, not UL listed)
  • Material: 304 stainless steel, 316L stainless steel, Powder-coated carbon steel, Aluminum, Polycarbonate, Fiberglass (FRP)
  • Size: inside or outside height, width and depth, with the depth your deepest component needs
  • Cutouts, glands and windows, dimensioned from one datum on each face
  • Mounting and access: wall, pole or stand, hinge side, mounting panel
  • Quantity: from one piece

Delivered in 10 business days, anywhere in the world. Counted from your order; for custom work, from your approval of the drawing.

Start a junction box from 8 × 8 × 4 inRequest a custom quote