Wall-mount enclosures · 316L stainless

24 × 16 × 8 in

24" x 16" x 8" 316L Stainless Steel Wall-Mount Enclosure, NEMA 4X Type, Hinged Door

Also in 304 stainless

$799.00Made to order
Configured forEmpty enclosure

IMD panel PC, door cut for size

Design your cutoutsHoles, glands, pushbuttons or a display opening on any face, in 3D. We quote it.Start →

Different holes, your own drawing or a quantity quote? Request a quote

  • Made to order Lead time confirmed with your order
  • Rating Manufacturer-rated NEMA 4X-type / IP66 - not UL listed
  • Checkout Secure checkout by Industrial Monitor Direct
  • IP66 gasketed door
  • 316L Stainless Steel
  • Mounting panel included
  • Continuous hinge
  • Wall-mount feet
  • Mini PC ready
  • Optional display cutout

Interactive 3D

Turn it over before you order.

The model follows the configuration you pick above. Drag to rotate, pinch or scroll to zoom.

Loading 3D model…

Details

Specifications

A 24 x 16 x 8 inch (610 x 406 x 203 mm) wall-mount enclosure in 316L stainless steel, #4 brushed finish, for washdown, food and beverage, outdoor and corrosive locations. The door seals on a continuous gasket, swings on a full-length hinge and closes with two quarter-turn latches, top one keyed. A removable mounting panel and four wall-mount feet are included.

Outside dimensions (H x W x D)
24 x 16 x 8 in (610 x 406 x 203 mm), body only
Inside dimensions (H x W x D, nominal)
23.88 × 15.88 × 7.88 in (606.6 × 403.4 × 200.2 mm)
Mounting panel (H x W, nominal)
21.48 × 13.48 in (545.6 × 342.4 mm)
Usable depth (nominal)
7.28 in (184.9 mm), mounting panel to door
Material
316L stainless steel, #4 brushed finish
Sheet thickness
1.5 mm (16 ga)
Rating
IP66 / NEMA 4X-type construction (manufacturer rated, not UL listed)
Door
Single door on a continuous hinge, continuous gasket
Latching
Two quarter-turn latches, top one keyed
Mounting panel
Included, galvanized steel, on welded studs
Mounting
Four external wall-mount feet
Grounding
Ground studs on body and door
IMD mini PC
Optional mount kit (VESA / DIN plate + 2 cable glands) for IMDRT120 / 121 / 122
Display cutout
Optional, for IMD 7" to 12.1" panel PCs
Lead time
Made to order; lead time confirmed with your order
Dimensioned front and side drawing, 24 x 16 x 8 in
Dimensioned front and side drawing, 24 x 16 x 8 in

Configured for an IMD mini PC

Choose the IMD mini PC configuration and the mounting panel comes with a VESA / DIN-rail adapter plate for an IMD fanless mini PC (IMDRT120, 121 or 122 series) and two extra cable glands on the bottom for power and network. The mini PC is sold separately: configure one here.

Display cutout for an IMD panel PC

Choose a cutout option and we laser-cut the door to the exact panel opening of your IMD panel PC, deburred and with mounting studs, before it ships. This door takes IMD panel PCs from 7" up to 12.1". Order the panel PC with the enclosure, or name the IMD model in the order note, and the opening is cut to that model.

316L stainless: is it the right grade?

316L adds molybdenum for better resistance to chlorides: the grade for coastal air, brine and chlorinated or caustic washdown. Compare 304 and 316L.

Custom version

Request a quote for this enclosure

Extra holes, a different cutout, your own drawing or a quantity quote: tell us what you need and attach a drawing if you have one. Our engineers check it and reply by email with a quote. Custom work is quoted, not priced online; the lead time is confirmed with your quote.

Design your cutoutsHoles, glands, pushbuttons or a display opening on any face, in 3D. We quote it.Start →

Wall-mount enclosures are manufacturer-rated NEMA 4X-type / IP66 - not UL listed. HMI enclosures are IP65-type at the front seal with the display installed. Once cutouts are added, the rating of the finished enclosure depends on properly rated components and cable glands being installed in every opening.