Schneider Electric Harmony GTU panel cutout dimensions

The Schneider Electric Harmony GTU HMIDT351 needs a panel cutout of 190 × 135 mm (7.48 × 5.31 in), width by height, and the HMIDT952 needs 465 × 319 mm (18.31 × 12.56 in). The table gives the opening for each of the 8 models, the bezel that covers it and the depth the document prints, from the maker's own document, which is linked below. Supported panel thickness: 1.6...5 mm (0.06...0.2 in).

Per model

Schneider Electric Harmony GTU cutout dimensions

Schneider Electric Harmony GTU: panel cutout per model, width × height
ModelScreenCutout W × H, mmCutout W × H, inBezel W × HDepthAs the document prints itCutout designer
HMIDT3517"190 × 135 mm7.48 × 5.31 in *203.6 × 148.6 mm36 mm190 × 135 mm (p. 49 (spec), 88 (panel cut))Lay it out
HMIDT55110.1"255 × 185 mm10.04 × 7.28 in *268.5 × 198.5 mm67 mm255 × 185 mm (p. 49 (spec), 88 (panel cut))Lay it out
HMIDT54210.4"259 × 201 mm10.20 × 7.91 in *272.5 × 214.5 mm67 mm259 × 201 mm (p. 48 (spec), 88 (panel cut))Lay it out
HMIDT65112.1"295 × 217 mm11.61 × 8.54 in *308.5 × 230.5 mm67 mm295 × 217 mm (p. 49 (spec), 88 (panel cut))Lay it out
HMIDT642 / HMIDT64312.1"301.5 × 227.5 mm11.87 × 8.96 in *315 × 241 mm67 mm301.5 × 227.5 mm (p. 48 (spec), 88 (panel cut))Lay it out
HMIDT73215"383.5 × 282.5 mm15.10 × 11.12 in *397 × 296 mm67 mm383.5 × 282.5 mm (p. 48 (spec), 88 (panel cut))Lay it out
HMIDT75215.6"396 × 277 mm15.59 × 10.91 in *414 × 295 mm69 mm396 × 277 mm (p. 49 (spec), 88 (panel cut))Lay it out
HMIDT95218.5"465 × 319 mm18.31 × 12.56 in *483 × 337 mm69 mm465 × 319 mm (p. 49 (spec), 88 (panel cut))Lay it out

* converted at 25.4 mm to the inch from the unit the document prints; the printed figure is in the column "As the document prints it".

Source: Harmony GTU User Manual, EIO0000001735, 02/2022, read on November 12, 2026. Width is the horizontal side with the terminal mounted in landscape, as the document draws it.

To one scale

The openings side by side

Solid outline: the cutout. Dashed outline: the bezel that has to land on flat door around it, drawn centred on the cutout. Leave the bezel clear of the door stiffeners, the hinge and the latch.

HMIDT952HMIDT752HMIDT642 / HMIDT643HMIDT651HMIDT542HMIDT551HMIDT351
Door covered by the bezel
ModelBezel wider than the cutout byTaller by
HMIDT35113.6 mm13.6 mm
HMIDT55113.5 mm13.5 mm
HMIDT54213.5 mm13.5 mm
HMIDT65113.5 mm13.5 mm
HMIDT642 / HMIDT64313.5 mm13.5 mm
HMIDT73213.5 mm13.5 mm
HMIDT75218 mm18 mm
HMIDT95218 mm18 mm

Totals across both sides. Where the terminal sits centred on its cutout, half of each figure lands on the door at each edge; the drawing in the document shows whether it does.

From the maker's documents

Panel thickness, mounting and front rating

Panel thickness
1.6...5 mm (0.06...0.2 in)
Cutout tolerance
+1/-0 mm (+0.04/-0 in)
Corner radius
R in angle below R3 (R0.12 in)
Mounting
The display module goes into the panel cut from the front; the box module attaches to the display module.
Front rating, as the maker states it
IP66F, IP67F, Type 1, Type 4X (indoor use only), Type 13, on the front panel when properly installed in an enclosure (Smart Display: and not using the front panel USB port).
Notes
Harmony GTU display modules carry HMIDT catalog numbers. Cutout and depth are the display module's, from the manual's specification table; the box module attaches behind it.

A terminal's front rating is its maker's, and it holds only when the terminal is mounted as that document instructs, in an enclosure of a matching type. The assembled rating is limited by the weakest fitting on the enclosure.

In the enclosure

What the opening needs from the door

Room on the door

The bezel is larger than the cutout on every side, and the mounting clips sit behind it. Place the opening so the bezel lands on flat sheet, and keep the depth of the terminal plus the connectors and the cable bend inside the usable depth of the enclosure: each size's usable depth is in the enclosure size chart.

Heat and the seal

A terminal adds its own heat to a sealed box; check the total in the enclosure heat calculator. The gasket seals against the door face, so the cut edge has to be flat and free of burrs. More on door openings in the guide to cutouts, glands and HMI windows.

Need the opening cut for you?

The cutout, cut into a stainless door at the factory.

Send the terminal's model, or enter its cutout and bezel under "My own display" in the cutout designer. We draw the opening on a 304 or 316L stainless enclosure in your size, you approve the drawing, and it is cut before it ships. From one piece. Delivered in 10 business days, anywhere in the world. Counted from your approval of the drawing.

Same maker

Other Schneider Electric series

Harmony GTO · Harmony ST6 · every series by screen size

Harmony, Schneider Electric and the product names on this page are trademarks of their owners. NEMA4 Enclosure is not affiliated with or endorsed by them. The dimensions are quoted from the documents cited for panel layout; a maker can revise a drawing at any time, so check the current document for your exact catalog number before you cut.

Asked and answered

Harmony GTU: questions

What is the panel cutout for the Schneider Electric Harmony GTU HMIDT351?

190 × 135 mm (7.48 × 5.31 in), width by height, behind a bezel of 203.6 × 148.6 mm. The document prints it as: 190 × 135 mm.

What is the panel cutout for the Schneider Electric Harmony GTU HMIDT551?

255 × 185 mm (10.04 × 7.28 in), width by height, behind a bezel of 268.5 × 198.5 mm. The document prints it as: 255 × 185 mm.

What is the panel cutout for the Schneider Electric Harmony GTU HMIDT542?

259 × 201 mm (10.20 × 7.91 in), width by height, behind a bezel of 272.5 × 214.5 mm. The document prints it as: 259 × 201 mm.

What is the panel cutout for the Schneider Electric Harmony GTU HMIDT651?

295 × 217 mm (11.61 × 8.54 in), width by height, behind a bezel of 308.5 × 230.5 mm. The document prints it as: 295 × 217 mm.

What panel thickness does the Schneider Electric Harmony GTU mount in?

The document states: 1.6...5 mm (0.06...0.2 in).

Can you cut the Harmony GTU opening into a stainless enclosure?

Yes. Send the model, or enter its cutout and bezel in the cutout designer under "My own display". We draw the opening on a 304 or 316L stainless enclosure in your size and cut it at the factory after you approve the drawing. Our standard enclosures are rated NEMA 4X / IP66 by the manufacturer; not UL listed; with a terminal installed, the assembled rating is limited by the weakest fitting.