Pro-face ST6000 Series panel cutout dimensions
The Pro-face ST6000 Series ST-6200WA needs a panel cutout of 118.5 × 92.5 mm (4.67 × 3.64 in), width by height, and the ST-6700WA needs 394 × 250 mm (15.51 × 9.84 in). The table gives the opening for each of the 7 models, the bezel that covers it and the depth the document prints, from the maker's own document, which is linked below. Check the current drawing for your exact catalog number before cutting.
Per model
Pro-face ST6000 Series cutout dimensions
| Model | Screen | Cutout W × H, mm | Cutout W × H, in | Bezel W × H | Depth | As the document prints it | Cutout designer |
|---|---|---|---|---|---|---|---|
| ST-6200WA | 4.3" | 118.5 × 92.5 mm | 4.67 × 3.64 in * | 134.5 × 108.5 mm | 43 mm | 118.5 mm (4.67 in) × 92.5 mm (3.64 in) (Spec table p.31; Panel Cut Dimensions p.55) | Lay it out |
| ST-6300TA | 5.7" | 156 × 123.5 mm | 6.14 × 4.86 in * | 169.5 × 137 mm | 58 mm | 156 mm (6.14 in) × 123.5 mm (4.86 in) (Spec table p.32; Panel Cut Dimensions p.55) | Lay it out |
| ST-6400WA | 7" | 190 × 135 mm | 7.48 × 5.31 in * | 208 × 153 mm | 45 mm | 190 mm (7.48 in) × 135 mm (5.31 in) (Spec table p.31; Panel Cut Dimensions p.55) | Lay it out |
| ST-6500WA | 10.1" | 255 × 185 mm | 10.04 × 7.28 in * | 273 × 203 mm | 47 mm | 255 mm (10.04 in) × 185 mm (7.28 in) (Spec table p.31; Panel Cut Dimensions p.55) | Lay it out |
| ST-6500TA | 10.4" | 301.5 × 227.5 mm | 11.87 × 8.96 in * | 315 × 241 mm | 55.3 mm | 301.5 mm (11.87 in) × 227.5 mm (8.96 in) (Spec table p.32; Panel Cut Dimensions p.55) | Lay it out |
| ST-6600WA | 12.1" | 295 × 217 mm | 11.61 × 8.54 in * | 313 × 235 mm | 50 mm | 295 mm (11.61 in) × 217 mm (8.54 in) (Spec table p.31-32; Panel Cut Dimensions p.55) | Lay it out |
| ST-6700WA | 15.6" | 394 × 250 mm | 15.51 × 9.84 in * | 412 × 268 mm | 50 mm | 394 mm (15.51 in) × 250 mm (9.84 in) (Spec table p.32; Panel Cut Dimensions p.55-56) | Lay it out |
* converted at 25.4 mm to the inch from the unit the document prints; the printed figure is in the column "As the document prints it".
Source: ST6000 Series Hardware Manual, ST6000-MM01-EN.05, 01/2024, read on November 12, 2026. Width is the horizontal side with the terminal mounted in landscape, as the document draws it.
To one scale
The openings side by side
Solid outline: the cutout. Dashed outline: the bezel that has to land on flat door around it, drawn centred on the cutout. Leave the bezel clear of the door stiffeners, the hinge and the latch.
| Model | Bezel wider than the cutout by | Taller by |
|---|---|---|
| ST-6200WA | 16 mm | 16 mm |
| ST-6300TA | 13.5 mm | 13.5 mm |
| ST-6400WA | 18 mm | 18 mm |
| ST-6500WA | 18 mm | 18 mm |
| ST-6500TA | 13.5 mm | 13.5 mm |
| ST-6600WA | 18 mm | 18 mm |
| ST-6700WA | 18 mm | 18 mm |
Totals across both sides. Where the terminal sits centred on its cutout, half of each figure lands on the door at each edge; the drawing in the document shows whether it does.
From the maker's documents
Panel thickness, mounting and front rating
- Panel thickness
- 1.6...5 mm (0.06...0.2 in). ST-6200WA on spring clips: 1.5...4 mm (0.06...0.16 in) in position 1, 4...6 mm (0.16...0.24 in) in position 2.
- Cutout tolerance
- +1/-0 mm (+0.04/-0 in)
- Corner radius
- below R3 (R0.12 in)
- Mounting
- From the front, held by installation fasteners against a gasket; the ST-6200WA can also be held by spring clips.
- Front rating, as the maker states it
- IP65F, UL 50/50E, Type 1, Type 4X (indoor use only), Type 13 (ST-6xxxTA models: Type 12 and Type 13), on the front panel when properly installed in an enclosure.
- Notes
- The manual warns that even inside the stated thickness range a panel can warp, depending on its material, its size and where the terminal sits, and may need strengthening.
A terminal's front rating is its maker's, and it holds only when the terminal is mounted as that document instructs, in an enclosure of a matching type. The assembled rating is limited by the weakest fitting on the enclosure.
In the enclosure
What the opening needs from the door
Room on the door
The bezel is larger than the cutout on every side, and the mounting clips sit behind it. Place the opening so the bezel lands on flat sheet, and keep the depth of the terminal plus the connectors and the cable bend inside the usable depth of the enclosure: each size's usable depth is in the enclosure size chart.
Heat and the seal
A terminal adds its own heat to a sealed box; check the total in the enclosure heat calculator. The gasket seals against the door face, so the cut edge has to be flat and free of burrs. More on door openings in the guide to cutouts, glands and HMI windows.
Need the opening cut for you?
The cutout, cut into a stainless door at the factory.
Send the terminal's model, or enter its cutout and bezel under "My own display" in the cutout designer. We draw the opening on a 304 or 316L stainless enclosure in your size, you approve the drawing, and it is cut before it ships. From one piece. Delivered in 10 business days, anywhere in the world. Counted from your approval of the drawing.
Same maker
Other Pro-face series
Pro-face, Schneider Electric and the product names on this page are trademarks of their owners. NEMA4 Enclosure is not affiliated with or endorsed by them. The dimensions are quoted from the documents cited for panel layout; a maker can revise a drawing at any time, so check the current document for your exact catalog number before you cut.
Asked and answered
ST6000 Series: questions
What is the panel cutout for the Pro-face ST6000 Series ST-6200WA?
118.5 × 92.5 mm (4.67 × 3.64 in), width by height, behind a bezel of 134.5 × 108.5 mm. The document prints it as: 118.5 mm (4.67 in) × 92.5 mm (3.64 in).
What is the panel cutout for the Pro-face ST6000 Series ST-6300TA?
156 × 123.5 mm (6.14 × 4.86 in), width by height, behind a bezel of 169.5 × 137 mm. The document prints it as: 156 mm (6.14 in) × 123.5 mm (4.86 in).
What is the panel cutout for the Pro-face ST6000 Series ST-6400WA?
190 × 135 mm (7.48 × 5.31 in), width by height, behind a bezel of 208 × 153 mm. The document prints it as: 190 mm (7.48 in) × 135 mm (5.31 in).
What is the panel cutout for the Pro-face ST6000 Series ST-6500WA?
255 × 185 mm (10.04 × 7.28 in), width by height, behind a bezel of 273 × 203 mm. The document prints it as: 255 mm (10.04 in) × 185 mm (7.28 in).
What panel thickness does the Pro-face ST6000 Series mount in?
The document states: 1.6...5 mm (0.06...0.2 in). ST-6200WA on spring clips: 1.5...4 mm (0.06...0.16 in) in position 1, 4...6 mm (0.16...0.24 in) in position 2..
Can you cut the ST6000 Series opening into a stainless enclosure?
Yes. Send the model, or enter its cutout and bezel in the cutout designer under "My own display". We draw the opening on a 304 or 316L stainless enclosure in your size and cut it at the factory after you approve the drawing. Our standard enclosures are rated NEMA 4X / IP66 by the manufacturer; not UL listed; with a terminal installed, the assembled rating is limited by the weakest fitting.