Custom enclosures, delivered in 10 business days

You define the material, the height, width and depth, and every cutout. We build it from one piece and ship it direct to your site, anywhere in the world.

Counted from your approval of the drawing.

Target: NEMA 1, 3R, 4, 4X, 6P, 12 or 13 (the type you choose), manufacturer rated, confirmed on your approval drawing; not UL listed.

Ready-made builds in the enclosure builder, rendered from the same 3D model you configure. Start from one, or from scratch.

Where to start

You define

Material, size, cutouts and NEMA type. We build the rest.

01

Material

Choose the material for the environment. Other alloys and finishes on request: tell us in the quote form.

304 vs 316L guide
  • 304 stainless steel#4 brushed. Indoor washdown, food and beverage, most outdoor sites.
  • 316L stainless steelFor salt air, brine, chlorides, pharma and chemical areas.
  • Powder-coated carbon steelIndoor and sheltered industrial panels. RAL 7035 light grey; other colours on request.
  • AluminumLight and corrosion resistant, for mobile and weight-sensitive builds.
  • PolycarbonateNon-metallic. Standard molded sizes, cut to your layout.
  • Fiberglass (FRP)Non-metallic and chemical resistant. Standard molded sizes, cut to your layout.

Swatches are drawings, not colour samples.

02

Size

Any height, width and depth up to 72 × 60 × 24 in (1829 × 1524 × 610 mm), in inches or millimetres; larger on request. Polycarbonate and fiberglass come in standard molded sizes. Tell us how it mounts: wall, pole, VESA arm, pedestal or stand.

Custom size limit 72 × 60 × 24 in with standard sizes 60 × 36 × 16, 24 × 20 × 8, 6 × 4 × 4 in, to scale72 × 60 × 2460 × 36 × 1624 × 20 × 86 × 4 × 4H × WD × H
To scale, in inches: the dashed outline is the largest custom size; inside it, three of our standard sizes, front and side.

03

Cutouts

Display openings, 22 and 30 mm operators, cable glands, connectors, fans, filters and windows, placed in our cutout designer or taken from your drawing (PDF, DXF, DWG or STEP).

Door, 609.6 × 508 mm, with a 363 × 283 mm panel PC opening and three operator holesØ22 · Ø30 · Ø22508363609.6283mm
To scale, in mm: the door of the 24 × 20 × 8 in 304 enclosure with the opening for an IMD 15" panel PC from its reference CAD; the three operator holes are an example.

04

Seven NEMA types: built to the one your site needs

NEMA types explained
  • Type 1Indoor, general purpose
  • Type 3ROutdoor: rain, sleet, snow
  • Type 4Indoor/outdoor: hose-directed water, washdown
  • Type 4XType 4 plus corrosion resistance
  • Type 6PProlonged submersion
  • Type 12Indoor: dust, dirt, dripping liquids
  • Type 13Indoor: oil and coolant spray

Target: NEMA 1, 3R, 4, 4X, 6P, 12 or 13 (the type you choose), manufacturer rated, confirmed on your approval drawing; not UL listed. Ratings are manufacturer ratings for the specified design; the enclosures are not UL listed. Hazardous-location types (NEMA 7 and 9) are not offered. NEMA does not test, certify or endorse enclosures.

How it works

Three steps, then 10 business days from your approval of the drawing.

Open the enclosure builder
  1. 01

    Send your spec

    Size, material, NEMA type and cutouts: fill in the quote form, upload your drawing or lay the cutouts out in the designer.

  2. 02

    Approve the drawing

    Our engineers check the fit and email you a quote with a dimensioned drawing to approve. No payment until you order.

  3. 03

    Delivered in 10 business days

    We build your enclosure from one piece and ship it direct to your site, anywhere in the world.

Before we cut metal

You approve a dimensioned drawing first.

All reference drawings
Dimensioned door-cutout drawing for the 24 × 20 × 8 in 304 stainless enclosure: cutout size and position, door section, title block
This is what an approval drawing looks like: the published door-cutout drawing for the 24 × 20 × 8 in 304 enclosure, door cut for an IMD panel PC. Yours shows your size, material and cutouts. Door-cutout drawing (PDF) · Enclosure drawing (PDF)
  • Size and materialOutside and nominal inside dimensions, material, finish and the NEMA type of the design.
  • Every cutoutSize, shape and position of each opening, dimensioned from the edges, with the face it is on.
  • Revisions before approvalSomething not right? Tell us and we send a revised drawing. Nothing is cut until you approve it.
  • When the 10 business days startOn the day you approve the drawing. Delivery is 10 business days from then, anywhere in the world.

Custom stainless steel enclosures

304 or 316L: a standard body with your cutouts, or a size of your own.

Grades by environment, the standard bodies to start from, where each is used and what to put on the drawing.

Custom stainless steel enclosures

Kiosk & operator stations

Operator stations built around IMD panel PCs, IMD touch monitors with an IMD mini PC inside, and the operator devices your process needs. Tell us how it mounts: wall, VESA arm, pedestal or stand.

From one piece

One prototype or a production run: the same build and the same 10-business-day delivery. Net 30 for approved accounts; purchase orders welcome.

Request a quote

Tell us the size, material and NEMA type, and attach your drawing (PDF, DXF, DWG, STEP or a photo of a sketch). Our engineers reply by email, usually within one business day, with a quote and a drawing to approve; your enclosure is delivered 10 business days after you approve it. Prefer to lay the cutouts out yourself? Use the cutout designer on the closest standard size.

Or email sales@nema4enclosure.com.

Wall-mount enclosures are rated NEMA 4X / IP66 by the manufacturer; not UL listed. HMI enclosures: IP65-type front seal with the display installed, manufacturer rated; not UL listed. Once cutouts are added, the rating of the finished enclosure depends on properly rated components and cable glands being installed in every opening.

Size, material and project details Optional; a drawing or description is enough to start.
Size you need (H × W × D)

We reply from sales@nema4enclosure.com. Nothing is emailed to you automatically; this page shows your RFQ number.