Kiosk & operator stations
Operator stations built around IMD panel PCs, IMD touch monitors with an IMD mini PC inside, and the operator devices your process needs. Tell us how it mounts: wall, VESA arm, pedestal or stand.
You define the material, the height, width and depth, and every cutout. We build it from one piece and ship it direct to your site, anywhere in the world.
Counted from your approval of the drawing.
Target: NEMA 1, 3R, 4, 4X, 6P, 12 or 13 (the type you choose), manufacturer rated, confirmed on your approval drawing; not UL listed.
No drawing yet
Pick the type, size, material and NEMA type in the enclosure builder.
Open the enclosure builderStandard size, custom holes
Pick a standard size, then place holes, glands and displays in the cutout designer.
Open the cutout designerYou have a drawing
Attach your drawing to the quote form below; our engineers reply by email.
Go to the quote formYou define
01
Choose the material for the environment. Other alloys and finishes on request: tell us in the quote form.
304 vs 316L guideSwatches are drawings, not colour samples.
02
Any height, width and depth up to 72 × 60 × 24 in (1829 × 1524 × 610 mm), in inches or millimetres; larger on request. Polycarbonate and fiberglass come in standard molded sizes. Tell us how it mounts: wall, pole, VESA arm, pedestal or stand.
03
Display openings, 22 and 30 mm operators, cable glands, connectors, fans, filters and windows, placed in our cutout designer or taken from your drawing (PDF, DXF, DWG or STEP).
Target: NEMA 1, 3R, 4, 4X, 6P, 12 or 13 (the type you choose), manufacturer rated, confirmed on your approval drawing; not UL listed. Ratings are manufacturer ratings for the specified design; the enclosures are not UL listed. Hazardous-location types (NEMA 7 and 9) are not offered. NEMA does not test, certify or endorse enclosures.
How it works
Size, material, NEMA type and cutouts: fill in the quote form, upload your drawing or lay the cutouts out in the designer.
Our engineers check the fit and email you a quote with a dimensioned drawing to approve. No payment until you order.
We build your enclosure from one piece and ship it direct to your site, anywhere in the world.

Custom stainless steel enclosures
Grades by environment, the standard bodies to start from, where each is used and what to put on the drawing.
Custom stainless steel enclosuresOperator stations built around IMD panel PCs, IMD touch monitors with an IMD mini PC inside, and the operator devices your process needs. Tell us how it mounts: wall, VESA arm, pedestal or stand.
One prototype or a production run: the same build and the same 10-business-day delivery. Net 30 for approved accounts; purchase orders welcome.
Tell us the size, material and NEMA type, and attach your drawing (PDF, DXF, DWG, STEP or a photo of a sketch). Our engineers reply by email, usually within one business day, with a quote and a drawing to approve; your enclosure is delivered 10 business days after you approve it. Prefer to lay the cutouts out yourself? Use the cutout designer on the closest standard size.
Or email sales@nema4enclosure.com.
Wall-mount enclosures are rated NEMA 4X / IP66 by the manufacturer; not UL listed. HMI enclosures: IP65-type front seal with the display installed, manufacturer rated; not UL listed. Once cutouts are added, the rating of the finished enclosure depends on properly rated components and cable glands being installed in every opening.
Your cart is empty.
Popular sizes
6 × 6 × 4 inTerminal box · 304 stainless
10 × 8 × 6 inSmall control box · 304 stainless
20 × 16 × 8 inCompact control panel · 304 stainless
30 × 24 × 10 inControl panel · 304 stainless
48 × 36 × 12 inLarge control panel · 304 stainless
15.6" HMI enclosureHMI · 304 stainless, for an IMD 15.6" panel PC or touch monitor + mini PCCoastal air, brine or chlorinated washdown? Every wall size in 316L