Metal or plastic round box for an outdoor camera

Either material works: the antennas live in the camera head in front of the box, so a metal 4 in [100 mm] round box costs you no Wi-Fi. Pick die-cast metal for impact, heat spreading and solid hub threads; pick non-metallic against copper-treated wood, wet cedar and salt air. Either way, choose a box listed for wet locations with about 20 cu in and seal the hub, the plugs and the canopy gasket.

NEMA4 Enclosure engineering team · Published November 17, 2026 · 6 min read

Short answer: either material works, and the Wi-Fi worry is the wrong question. The radios and antennas of a floodlight camera sit in the head that bolts to the front of the box, so a die-cast 4 in [100 mm] round box lives behind the antennas and costs you no signal. Decide on everything else instead. Die-cast metal wins on impact, heat spreading and threaded hubs; non-metallic wins against wet or copper-treated wood, where bare aluminum corrodes. Either way, buy a box listed for wet locations with about 20 cu in inside, and spend your attention on the seals: the hub ring, the plugs and the camera's canopy gasket.

Why the box never touches the Wi-Fi

A hardwired floodlight camera carries its antennas in the head, ahead of its own base plate. Your box mounts behind that plate and holds nothing but splices, so the radio waves never cross the box walls. Metal or plastic, the link to your router is the same.

Even a radio that must live inside a metal enclosure usually keeps working, because gasketed covers and cable entries leak signal — why a radio still works inside a metal enclosure covers that case. Your layout is easier still. The one arrangement that costs you bars is a head recessed into a metal opening, so mount the head flat on the box face the way its maker intended and move on to the choices that matter.

Side by side at 4 in

What you weigh Die-cast aluminum round box Non-metallic round box
Wet-location use Listed for wet locations; the 1/2 in [13 mm] threaded hub takes a sealing ring Listed for wet locations; 1/2 in or 3/4 in hubs closed by gasketed plugs
Volume About 20 cu in stamped inside About 20 cu in stamped inside, with plugs supplied for the spare hubs
Grounding Box bonds through its ground screw; paint comes off the contact face With NM-B or UF supply, the ground lands on the connector and the box needs nothing
Impact Dents from ladders and trimmer line and stays shut A hard blow cracks it; UV-stable grades still last years outdoors
Heat Moves the head's heat out through the wall Insulates; harmless at LED head power
Against the wall Bare aluminum corrodes against copper-treated wood unless isolated Inert against wood, siding and stainless fasteners

Where die-cast metal wins

Put metal where the box can be hit. A die-cast round box shrugs off a leaning ladder, an ice scrape and string-trimmer line. It dents and keeps its seal, where the same hit can crack a molded box. The 1/2 in hub threads also hold a sealing ring and locknut at full torque for years, which is what keeps that entry weathertight.

Heat moves through metal. Aluminum alloys conduct roughly 100-200 W/m·K against about 0.2 W/m·K for PVC — on the order of a thousand times more — so whatever warmth the head passes into the box leaves through the wall. An LED floodlight head sends only a few watts back there, so treat heat as a tie-breaker rather than a driver. A metal box is also naturally in the grounding path: land the equipment grounding conductor on its ground screw. Where the box is painted, take the paint off the contact face first; NEC 250.12 asks for paint, lacquer and enamel off the contact surfaces at grounding connections. With a metal-conduit supply, the box carries the bond with no extra parts.

Where non-metallic wins

The wall behind the box decides this one. Copper-rich preservative-treated lumber is marked to be used with stainless or hot-dip-galvanized contact, and it corrodes bare aluminum pressed against it. Wet cedar and redwood stain aluminum black. A PVC back is inert against all of those, and it leaves no gray streak on painted siding along the fasteners. Near salt water, aluminum pits within a few years while non-metallic boxes stay dull but sound.

Non-metallic also simplifies the ground path. Fed with NM-B or UF cable, the box needs no bond of its own: the equipment grounding conductor lands on the wire connector with the fixture lead. One rule to respect: if the supply comes in metal conduit or metal-clad cable, NEC 314.3 allows a non-metallic box only with those metal parts bonded together inside it. For larger weatherproof boxes, where the material choice is polycarbonate or fiberglass, polycarbonate vs fiberglass enclosures works through that decision.

The seals that decide the rating

Both boxes hold their wet-location listing only as installed, and four seals carry it:

If the supply comes through the wall instead of a hub, sealing a camera junction box back entry without conduit covers the gland choice. Keep the box sealed rather than drilled: NEC 314.15 permits drainage openings of 3 mm to 6 mm [1/8 to 1/4 in] in boxes listed for damp or wet locations, but those belong to vented Type 3R designs that shed rain — the 3R versus 4 comparison explains the difference. Your camera box seals instead of draining.

The fill check with numbers

Volume is where an install fails inspection quietly. Count the NEC box-fill allowances, then buy on the number stamped inside the box; round weatherproof boxes in this size run about 20 cu in. If the feeding circuit is still open, tapping power for an outdoor floodlight sorts the supply side first.

For the common floodlight-camera splice set, assuming 12 AWG supply conductors and 14 AWG head leads:

  • Two 12 AWG supply conductors (line and neutral): 2 x 2.25 cu in = 4.50 cu in
  • Equipment grounding conductor, one allowance at the largest ground size: 2.25 cu in
  • Three 14 AWG fixture leads to the head: 3 x 2.00 cu in = 6.00 cu in
  • Fixture stud, one allowance at the largest conductor present: 2.25 cu in

Total: 4.50 + 2.25 + 6.00 + 2.25 = 15.00 cu in, leaving about 5 cu in of the 20 for the wire connectors. Wire connectors add no allowance themselves; internal cable clamps would add one more at the largest conductor. Step the supply up to 10 AWG and the set grows to 16.00 cu in — the conductors cost 2 x 2.50, the ground 2.50, the stud 2.50, the leads stay at 6.00 — still inside a 20 cu in box with 4 cu in to spare. Smaller head leads count less: three 16 AWG leads total 5.25 cu in instead of 6.00.

Decide by the wall behind it

Where it mounts Box to pick
Under an eave or soffit, splices only Either; non-metallic installs fastest, with no box bond
Vertical wood or fiber-cement siding Either; die-cast where ladders and trimmers can reach
Copper-treated lumber or wet cedar Non-metallic, or an isolation layer behind an aluminum box
Coastal, salt air Non-metallic here; 316L stainless for bigger splice points
Supply in metal conduit or metal-clad cable Metal box bonds through its screw; non-metallic only with the metal parts bonded inside
Fill sum above the stamped volume A deeper round box, or a small stainless junction box

For the bigger splice point near salt or driving weather — the one that has to survive on its own enclosure rather than under the camera's canopy — 316L stainless junction boxes are the step up: rated NEMA 4X / IP66 by the manufacturer and not UL listed, delivered in 10 business days counted from your order. Outdoor enclosure basics collect the rest of that story.

What to order

  • A round box listed for wet locations, with the wet-locations marking printed on the box itself.
  • About 20 cu in stamped inside for the example set; more if your supply conductors are 10 AWG.
  • One 1/2 in threaded hub with a sealing ring, or the back-entry gland if the cable comes through the wall.
  • Gasketed plugs for every unused hub — four on the common 5-hole non-metallic box.
  • A stud or hole pattern matching the camera base; hold the base against the box before mounting either.
  • Stainless fasteners into treated wood, whichever box you choose.

Catalog dimensions to compare

Compare these catalog dimensions with your component layout. Open each enclosure for its rating, material and usable space, then check those specifications against your application.

EnclosureMaterialOutside H x W x D / displayRating
10 × 8 × 6 in316L stainless10 x 8 x 6 inRated NEMA 4X / IP66 by the manufacturer; not UL listed
12 × 10 × 6 in316L stainless12 x 10 x 6 inRated NEMA 4X / IP66 by the manufacturer; not UL listed
16 × 12 × 8 in316L stainless16 x 12 x 8 inRated NEMA 4X / IP66 by the manufacturer; not UL listed
6 × 6 × 4 in316L stainless6 x 6 x 4 inRated NEMA 4X / IP66 by the manufacturer; not UL listed

Questions

Will a metal box block my floodlight camera's Wi-Fi?

No. The antennas are in the camera head that bolts to the front of the box, so the walls sit behind the radio. Even a radio enclosed in metal keeps a link: at 2.4 GHz the wavelength is about 4.9 in [125 mm], longer than a 4 in box, and gasketed covers leak. Mount the head on the box face and choose the material on corrosion, grounding and heat.

How much box volume do the splices need?

Count the NEC box-fill allowances: two 12 AWG conductors at 2.25 cu in each, one grounding allowance at 2.25, three 14 AWG fixture leads at 2.00 and the fixture stud at 2.25 add to 15 cu in. A 20 cu in box leaves about 5 cu in for the connectors. The same set on 10 AWG supply conductors needs 16 cu in. The allowed volume is stamped inside the box.

Does either box need bonding to ground?

A metal box does: land the equipment grounding conductor on its ground screw, and scrape paint off the contact face where the box is painted. The screw must be the listed one for the box, normally a 10-32 green hex-head screw in its tapped hole. A non-metallic box fed with NM-B or UF cable needs no box bond. With metal conduit or metal-clad cable, NEC 314.3 allows the non-metallic box only with those metal parts bonded together inside it.

Which material against treated-wood or cedar siding?

Non-metallic, or an isolation layer behind an aluminum box. Copper-rich treated lumber is marked for stainless or hot-dip-galvanized contact, and it corrodes bare aluminum; wet cedar stains it black. PVC is inert against all of those. On plain wood or fiber-cement siding, either material is fine.

Checklist before you order

Specify it once, built to your drawing

  • Environment and NEMA type: Type 1, Type 3R, Type 4, Type 4X, Type 6P, Type 12, Type 13 (manufacturer ratings, not UL listed)
  • Material: 304 stainless steel, 316L stainless steel, Powder-coated carbon steel, Aluminum, Polycarbonate, Fiberglass (FRP)
  • Size: inside or outside height, width and depth, with the depth your deepest component needs
  • Cutouts, glands and windows, dimensioned from one datum on each face
  • Mounting and access: wall, pole or stand, hinge side, mounting panel
  • Quantity: from one piece

Delivered in 10 business days, anywhere in the world. Counted from your order; for custom work, from your approval of the drawing.

Build it from 10 × 8 × 6 inRequest a custom quote