Short answer: give the two antennas a quarter wavelength of the lowest band the router works on, then let the metal box do the rest. A quarter wavelength is 4.2 in [10.7 cm] at 700 MHz and 3.3 in [8.3 cm] at 900 MHz, so 4 in [10 cm] centre-to-centre is the floor when both share a face. Opposite ends of that face beat any spacing trick. Keep the main lead on the primary port and the diversity lead on the aux port, and keep the whole cable run under 100 ft [30 m]. The short paddles you see screwed straight into a router are the exception: they are designed as a matched pair. Below is the number, its basis, and what it means for your cutout drawing.
Why the router has two cellular ports
The two ports are one transmitter and two receivers. The main port — marked MAIN or PRIMARY depending on the maker — carries the transmit signal and the first receive path. The aux port — AUX, or DIV for diversity — is receive only on most modules, and exists so the radio can sample the signal through a second antenna. When the two paths fade differently, the receiver picks the better one or combines both. On LTE, the second path also carries the second downlink MIMO stream.
Use both ports. The guidance for these routers is plain: two antennas give the best signal quality and download throughput, either as two separate antennas or as one dual-lead MIMO housing on both connectors. One antenna alone will still link up; what you give up is spelled out in the FAQ below.
| Port | Marked on the board | Job | Lead it gets |
|---|---|---|---|
| Main | MAIN, PRIMARY | Transmit + receive | Main lead of the pair |
| Aux | AUX, DIV | Receive diversity, second MIMO stream | Second lead |
The quarter-wavelength rule
Diversity works only when the two antennas see differently faded signals, and separation is what decorrelates them. RF diversity practice puts the minimum separation for real benefit at one quarter wavelength, and practical land-mobile guidance calls 1.5 to 2.5 wavelengths ideal. Marine installers, who have the room, want cellular antennas at least 20 in [50 cm] apart and prefer 35 in [90 cm] — inside that ideal band at 900 MHz.
Wavelength comes straight from frequency: wavelength = c / f, with c = 3 x 10⁸ m/s. Work it at the lowest band your router lists, because that is where the quarter wave is longest. The table does it for the common bands.
| Band | Frequency | Wavelength | Quarter wavelength |
|---|---|---|---|
| US 700 MHz LTE | 700 MHz | 16.9 in [42.9 cm] | 4.2 in [10.7 cm] |
| 900 MHz GSM / LTE B8 | 900 MHz | 13.1 in [33.3 cm] | 3.3 in [8.3 cm] |
| 1800 MHz LTE B3 | 1800 MHz | 6.6 in [16.7 cm] | 1.6 in [4.2 cm] |
| 2100 MHz LTE B1 | 2100 MHz | 5.6 in [14.3 cm] | 1.4 in [3.6 cm] |
| 2600 MHz LTE B7 | 2600 MHz | 4.5 in [11.5 cm] | 1.1 in [2.9 cm] |
So the rule for two antennas on one face: at least 4 in [10 cm] centre-to-centre, or the quarter wavelength of your lowest band when that is longer. A router whose band list starts at 700 MHz needs 4.2 in [10.7 cm]; one that stays at 900 MHz or above is satisfied at 3.3 in [8.3 cm].
Tower engineers size separation from height instead — the h/d = 11 rule gives a 100 ft [30 m] mast about 9 ft [2.7 m] between antennas — but that formula belongs to masts. Your enclosure hangs a few feet from a wall, so wavelength is the yardstick, not height.
Opposite ends, or opposite faces, beat raw distance
The box itself is free isolation. Two antennas on opposite faces of a stainless enclosure couple to each other only around the edges of the metal, so the box decorrelates them and the spacing question mostly dissolves. On a single face, push them to opposite ends: any face 12 in [305 mm] or wider clears the 700 MHz floor with room to spare. Crowded together in the middle of a face is the one layout to avoid — the antennas couple, their fading tracks together, and the second MIMO stream stops paying for itself.
Two refinements. When the tower bearing is known and you want directionality, aim both antennas the same way with the same quarter-wave floor between them; the antenna gain and coverage pattern piece covers choosing omni against directional. And when the face is genuinely small, rotate one antenna 90 degrees: cross-polarised antennas decorrelate even close together, which is exactly how matched paddle sets manage it.
For the whole layout — where the antennas sit relative to the door, the hinges and the cable entries — the outdoor router enclosure antenna layout article walks it end to end.
Why paddle antennas sit side by side
The short paddles sold as a pair for a router are tuned as a set: matched impedance, matched pattern, usually with the two elements polarised at 90 degrees to each other. The maker's pairing does the decorrelating, so distance is not doing the work — that is why the pair can hang a few centimetres apart. Two separate omnidirectional whips have none of that built in, which is why they need the quarter wave. Outdoors there is a second reason to prefer bulkhead whips on the enclosure wall: the router's own connectors stay inside, behind the gasket, and only rated connectors cross the metal.
Worked example: two antennas on a 12 x 10 in face, lowest band 700 MHz
Inputs: a cellular router whose band list runs from 700 MHz to 2100 MHz, from its spec sheet; an enclosure whose mounting face is 12 in wide by 10 in high [305 x 255 mm], from your drawing; two identical omnidirectional bulkhead antennas, from the order. Rule: wavelength = c / f with c = 3 x 10⁸ m/s, and the centre-to-centre separation must reach a quarter wavelength at the lowest band, 700 MHz.
The arithmetic:
- Wavelength = (3 x 10⁸ m/s) / (700 x 10⁶ Hz) = 0.429 m, so a quarter of it is 0.107 m = 4.2 in [10.7 cm]
- Antenna centres set 2 in [51 mm] in from each side edge: separation = 12 in − 2 in − 2 in = 8 in [203 mm]
- Against the floor: 8 in / 4.2 in = 1.9 times the minimum
- Against the top band: a quarter wavelength at 2100 MHz is 1.4 in [3.6 cm], and 8 in is 5.7 times that
Decision: both antennas go on that one face, one near each end, 8 in [203 mm] apart — clear of the 4.2 in [10.7 cm] threshold with margin. Main lead to the primary port, diversity lead to the aux port, both antennas the same model. If the shared face cannot deliver the quarter wave — a 6 in [152 mm] wide face leaves only 2 in [51 mm] between centres — split the pair across opposite faces instead.
Cable runs, cutouts and the seal
Two things now belong on your cutout drawing: the connector holes and the lead lengths. Vendor guidance for these routers caps the antenna cable run at 100 ft [30 m]. Inside an enclosure you will use a fraction of that. For a rooftop remount, use low-loss cable and keep the run as short as the route allows, because cable loss quietly spends the gain you bought.
Every hole takes a bulkhead connector — SMA on most of these radios — with a sealing rating of its own. The weakest part on the box sets the rating of the whole assembly, so a connector rated below the enclosure drags the box down to the connector's level. Match them. Our outdoor boxes are rated NEMA 4X / IP66 by the manufacturer; not UL listed. The cutouts, cable glands and HMI windows guide shows how to put holes on a drawing, and the cable and antenna entry placement article covers where entries belong. The router antenna bulkhead layout piece covers the connector side.
Delivery is 10 business days anywhere in the world, counted from your order; for custom cutouts, from your approval of the drawing.
What to specify
| Item | What to write on the order |
|---|---|
| Separation | Quarter wavelength of the lowest band; 4 in [10 cm] minimum on a shared face |
| Ports | Main lead on the primary port; diversity lead on the aux port |
| Antennas | Two identical omnidirectional whips, or one dual-lead MIMO housing |
| Layout | Opposite ends of one face, or opposite faces of the box |
| Connectors | Bulkhead type, each rated to match the enclosure |
| Cable | Pre-made leads, total run under 100 ft [30 m] |
For the box itself, start from the outdoor enclosure range for weather-exposed sites, or the stainless junction boxes when the antennas share a small enclosure with splices and terminals.
Catalog dimensions to compare
Compare these catalog dimensions with your component layout. Open each enclosure for its rating, material and usable space, then check those specifications against your application.
| Enclosure | Material | Outside H x W x D / display | Rating |
|---|---|---|---|
| 10 × 8 × 6 in | 304 stainless | 10 x 8 x 6 in | Rated NEMA 4X / IP66 by the manufacturer; not UL listed |
| 12 × 10 × 6 in | 304 stainless | 12 x 10 x 6 in | Rated NEMA 4X / IP66 by the manufacturer; not UL listed |
| 16 × 12 × 8 in | 304 stainless | 16 x 12 x 8 in | Rated NEMA 4X / IP66 by the manufacturer; not UL listed |
| 16 × 14 × 8 in | 304 stainless | 16 x 14 x 8 in | Rated NEMA 4X / IP66 by the manufacturer; not UL listed |
Questions
Are the main and aux antenna ports interchangeable?
No. The main port transmits and receives; the aux port is receive only on most modules, there for diversity and the second LTE downlink stream. If you fit just one antenna, it goes on the main port, because that is where the radio transmits.
How far apart should cellular and WiFi antennas be on the same enclosure?
Keep them on separate faces when you can. When they must share a face, a common vendor minimum for 2.4 GHz antennas is 4.9 in [12.5 cm] centre-to-centre — one full wavelength at 2.4 GHz — and the cellular pair should get at least that from the WiFi antennas.
What happens if I leave the diversity port empty?
The link still comes up on the main antenna alone. You lose the second receive stream, so 2x2 downlink MIMO throughput typically falls to around half in strong signal, and weak-signal operation suffers more, because diversity gain is what carries the link through fades.
Can the two antennas be too far apart?
Not on the box itself. Beyond about 1.5 to 2.5 wavelengths — 20 to 33 in [50 to 83 cm] at 900 MHz — extra separation adds little. The real ceiling is cable loss, which is why the run stays under 100 ft [30 m] on low-loss cable.
Can I use one MIMO antenna instead of two separate ones?
Yes. One housing with two leads to both ports is a fully supported build, and the pair inside is pre-spaced and matched — the same reason paddle sets can sit close together. Its main lead still lands on the main port.