Email us
Stainless Steel HMI Housing for Unitronics V1040 (10.4 in), Exact Cutout, 304 or 316L
Stainless Steel HMI Housing for Unitronics V1040 (10.4 in), Exact Cutout, 304 or 316L
Stainless Steel HMI Housing for Unitronics V1040 (10.4 in), Exact Cutout, 304 or 316L
Stainless Steel HMI Housing for Unitronics V1040 (10.4 in), Exact Cutout, 304 or 316L
Stainless Steel HMI Housing for Unitronics V1040 (10.4 in), Exact Cutout, 304 or 316L
Stainless Steel HMI Housing for Unitronics V1040 (10.4 in), Exact Cutout, 304 or 316L
Stainless Steel HMI Housing for Unitronics V1040 (10.4 in), Exact Cutout, 304 or 316L
Stainless Steel HMI Housing for Unitronics V1040 (10.4 in), Exact Cutout, 304 or 316L
Stainless Steel HMI Housing for Unitronics V1040 (10.4 in), Exact Cutout, 304 or 316L
Stainless Steel HMI Housing for Unitronics V1040 (10.4 in), Exact Cutout, 304 or 316L

View in 3D
A4
To scale beside an A4 sheet (210 × 297 mm)

316Lfor chlorides

Stainless Steel HMI Housing for Unitronics V1040 (10.4 in), Exact Cutout, 304 or 316L

HMI enclosures · 316L stainless 316L chloride grade

Stainless Steel HMI Housing for Unitronics V1040 (10.4 in), Exact Cutout, 304 or 316L 316L stainless

Material316L Stainless Steel (marine grade)
$589.00Made to order

Delivered in 10 business days, made to order, anywhere in the world

Add a note for this order

Goes with Buy now or Add to cart; the same note shows in your cart.

Stainless Steel HMI Housing for Unitronics V1040 (10.4 in), Exact Cutout, 304 or 316L

  • 3-year warrantyParts and labor on manufacturing defects, three years from the date you receive the unit.Warranty
  • 90-day returnsStandard products, unused, with an RMA number first. The display opening is laser-cut to the model you choose: ask us before ordering if you may need to return it. Operator holes or other changes make it a custom item, not returnable.Returns
  • Sold by Industrial Monitor DirectSold, shipped and supported by Industrial Monitor Direct, Sanford, Maine.1 (207) 800-1637
  • PurchasingNet 30 for approved accounts · W-9 on request · POs welcomeTerms & setup

Open the cutout designerHoles, glands, pushbuttons or a display opening on any face. We quote it.Start →

Another size, material or cutout, from one piece? Build it in 3D or request a quote

Mount it on a pedestal or an arm in the enclosure builder.

  • Rating IP65-type front seal with the display installed, manufacturer rated; not UL listed
  • Checkout Secure checkout by Industrial Monitor Direct
  • Exact V1040 cutout
  • Cable bay on the connector side
  • 304 or 316L stainless
  • Gasketed rear cover
  • 2D drawing + 3D model
  • Unitronics V130 / V350 HMI housing (2.4 in / 3.5 in, cutout 92 × 92 mm)
  • Unitronics V430 HMI housing (4.3 in, 480 x 272, cutout 122.5 × 91.5 mm)

Interactive 3D

Turn the housing over

The model follows the configuration you pick above. Drag to rotate, scroll to zoom, or pick a part below.

Loading 3D model…

Take the details with you

Stainless Steel HMI Housing for Unitronics V1040 (10.4 in), Exact Cutout, 304 or 316L: size reference

A reference for your project folder: body views at the same scale, nominal dimensions and the specification. Use the configuration-specific CAD for the build you select.

Download specification PDFDownload size image

Base configuration. Nominal reference, not a machining drawing. Final dimensions confirmed with your order.

Stainless Steel HMI Housing for Unitronics V1040 (10.4 in), Exact Cutout, 304 or 316L 316L stainless none in hmi housing: nominal body views and dimensions

Details

Specifications and files

Full specifications

14 rows: sizes, sheet, door, latching, mounting, rating

Turn a panel-mount Unitronics V1040 into a sealed, stand-alone operator station on a VESA arm, a pedestal or a wall. The front face is cut to Unitronics' published panel cutout, 274 × 230 mm, so the V1040 installs exactly as it does in a cabinet door: its own rubber seal against the face and its 8 brackets clamping from behind. There is a cable bay 97 mm wide beside the connector side, so the communication and power plugs go in straight, with room to bend the cables down to two cable glands under the bay. Built in 304 stainless, or 316L for washdown, coastal and shipboard use.

Fits
Unitronics V1040-T20B (10.4 in, 800 × 600); the controller is not included
Panel cutout
274 × 230 mm, from the Unitronics installation guide
Outside dimensions (H × W × D)
11.0 × 15.5 × 5.0 in (279 × 394 × 127 mm)
Alloy (ASTM A240)
Type 316L (AISI 316L, EN 1.4404, UNS S31603): 16.0–18.0 % chromium, 10.0–14.0 % nickel, 2.00–3.00 % molybdenum, carbon 0.030 % max (ASTM A240); pitting resistance (PREN) about 24
Room behind the front
123 mm; the V1040 needs 74.1 mm with a snap-in I/O module, the rest is for wiring
Cable bay
97 mm clear beside the V1040's connector side
Front panel
1.5 mm stainless, within the V1040's 5 mm maximum panel thickness
Material
304 stainless steel or 316L stainless steel (marine grade), #4 brushed
Rating
IP65-type front seal with the V1040 installed on its own gasket (manufacturer rated, not UL listed)
Rear
Removable gasketed cover, 8 screws, VESA 100 pattern
Cable entry
Two cable glands under the bay
Mounting
VESA 100 arm, pedestal or wall bracket (not included)
Shipping weight
about 12.3 lb boxed (estimated, final weight confirmed at dispatch)
Lead time
Made to order; delivered in 10 business days, anywhere in the world
Stainless Steel HMI Housing for Unitronics V1040 (10.4 in), Exact Cutout, 304 or 316L
Stainless Steel HMI Housing for Unitronics V1040 (10.4 in), Exact Cutout, 304 or 316L. Open full size

Drawings & CAD

STEP / CAD on request, by email

Nominal body dimensions; confirm critical dimensions before cutting or installing.

What's in the box

The parts, this size's options and what is not included
  • Rear service cover Removable gasketed cover, 8 screws, VESA 100 pattern
  • Cable glands Two cable glands under the bay

Not included

The panel PC, touch monitor or mini PC (sold by Industrial Monitor Direct), the VESA arm or pedestal, and the operator-strip devices.

Drawing and approval

Download the 2D drawing (PDF) with the cutout position, cable bay, glands and VESA pattern, or turn the 3D model above. After you order we email a dimensioned approval drawing; production starts when you confirm the cutout and the gland positions against your unit. Running a different Vision model or a UniStream panel? Send the model number and we draw the housing to it.

The rest of the Vision series

All models: Unitronics Vision HMI housings.

316L stainless: is it the right grade?

316L adds molybdenum for better resistance to chlorides: the grade for coastal air, brine and chlorinated or caustic washdown. Read the 304 vs 316L guide.

Buying guides

Ratings, sizing, heat and cutouts, before you order

Spotted a wrong number or a broken file? Report a problem with this page.

Nearby sizes

Compare

Engineering articles

Articles about this enclosure

All articles
Custom version

Request a quote for the Stainless Steel HMI Housing for Unitronics V1040 (10.4 in), Exact Cutout, 304 or 316L

Another size, extra holes, your drawing or a quantity quote: quoted by email, built from one piece.Open the quote form

Another size, extra holes, a different cutout, your own drawing or a quantity quote: tell us what you need and attach a drawing if you have one. Custom work is quoted, not priced online, and built from one piece.

  1. Quote by email Our engineers check your request and reply usually within one business day.
  2. Drawing You approve a dimensioned drawing before anything is cut.
  3. 10 business days From that approval to delivery, anywhere in the world.

This HMI housing has an IP65-type front seal with the display installed, manufacturer rated; not UL listed. Once cutouts are added, the rating of the finished enclosure depends on properly rated components and cable glands being installed in every opening.

Size, material and project details Optional; a drawing or description is enough to start.
This enclosure
Material
316L stainless steel
Rating
IP65-type front seal with the display installed, manufacturer rated; not UL listed

Need a different material or NEMA type? Build it in 3D first.

Different size? (H × W × D)

We reply from sales@nema4enclosure.com. Nothing is emailed to you automatically; this page shows your RFQ number.