Nominal body dimensions; confirm critical dimensions before cutting or installing.
Stainless Steel HMI Housing for Unitronics V570 (5.7 in), Exact Cutout, 304 or 316L
HMI enclosures · 316L stainless 316L chloride grade
Stainless Steel HMI Housing for Unitronics V570 (5.7 in), Exact Cutout, 304 or 316L 316L stainless
Stainless Steel HMI Housing for Unitronics V570 (5.7 in), Exact Cutout, 304 or 316L
- 3-year warrantyParts and labor on manufacturing defects, three years from the date you receive the unit.Warranty
- 90-day returnsStandard products, unused, with an RMA number first. The display opening is laser-cut to the model you choose: ask us before ordering if you may need to return it. Operator holes or other changes make it a custom item, not returnable.Returns
- Sold by Industrial Monitor DirectSold, shipped and supported by Industrial Monitor Direct, Sanford, Maine.1 (207) 800-1637
- PurchasingNet 30 for approved accounts · W-9 on request · POs welcomeTerms & setup
Another size, material or cutout, from one piece? Build it in 3D or request a quote
Mount it on a pedestal or an arm in the enclosure builder.
- Rating IP65-type front seal with the display installed, manufacturer rated; not UL listed
- Checkout Secure checkout by Industrial Monitor Direct
- Exact V570 cutout
- Cable bay on the connector side
- 304 or 316L stainless
- Gasketed rear cover
- 2D drawing + 3D model
- Unitronics V130 / V350 HMI housing (2.4 in / 3.5 in, cutout 92 × 92 mm)
- Unitronics V430 HMI housing (4.3 in, 480 x 272, cutout 122.5 × 91.5 mm)
Interactive 3D
Turn the housing over
The model follows the configuration you pick above. Drag to rotate, scroll to zoom, or pick a part below.

Loading 3D model…
Take the details with you
Stainless Steel HMI Housing for Unitronics V570 (5.7 in), Exact Cutout, 304 or 316L: size reference
A reference for your project folder: body views at the same scale, nominal dimensions and the specification. Use the configuration-specific CAD for the build you select.
Download specification PDFDownload size image
Base configuration. Nominal reference, not a machining drawing. Final dimensions confirmed with your order.

Details
Specifications and files
Full specifications
14 rows: sizes, sheet, door, latching, mounting, rating
Turn a panel-mount Unitronics V570 into a sealed, stand-alone operator station on a VESA arm, a pedestal or a wall. The front face is cut to Unitronics' published panel cutout, 182 × 124.5 mm, so the V570 installs exactly as it does in a cabinet door: its own rubber seal against the face and its 4 brackets clamping from behind. There is a cable bay 87 mm wide beside the connector side, so the communication and power plugs go in straight, with room to bend the cables down to two cable glands under the bay. Built in 304 stainless, or 316L for washdown, coastal and shipboard use.
- Fits
- Unitronics V570-57-T20B, V570-57-T20B-J (5.7 in, 320 × 240); the controller is not included
- Panel cutout
- 182 × 124.5 mm, from the Unitronics installation guide
- Outside dimensions (H × W × D)
- 7.0 × 11.5 × 5.5 in (178 × 292 × 140 mm)
- Alloy (ASTM A240)
- Type 316L (AISI 316L, EN 1.4404, UNS S31603): 16.0–18.0 % chromium, 10.0–14.0 % nickel, 2.00–3.00 % molybdenum, carbon 0.030 % max (ASTM A240); pitting resistance (PREN) about 24
- Room behind the front
- 136 mm; the V570 needs 85.9 mm with a snap-in I/O module, the rest is for wiring
- Cable bay
- 87 mm clear beside the V570's connector side
- Front panel
- 1.5 mm stainless, within the V570's 5 mm maximum panel thickness
- Material
- 304 stainless steel or 316L stainless steel (marine grade), #4 brushed
- Rating
- IP65-type front seal with the V570 installed on its own gasket (manufacturer rated, not UL listed)
- Rear
- Removable gasketed cover, 8 screws, VESA 100 pattern
- Cable entry
- Two cable glands under the bay
- Mounting
- VESA 100 arm, pedestal or wall bracket (not included)
- Shipping weight
- about 8.8 lb boxed (estimated, final weight confirmed at dispatch)
- Lead time
- Made to order; delivered in 10 business days, anywhere in the world

Drawings & CAD
STEP / CAD on request, by email
What's in the box
The parts, this size's options and what is not included
- Rear service cover Removable gasketed cover, 8 screws, VESA 100 pattern
- Cable glands Two cable glands under the bay
Not included
The panel PC, touch monitor or mini PC (sold by Industrial Monitor Direct), the VESA arm or pedestal, and the operator-strip devices.
Drawing and approval
Download the 2D drawing (PDF) with the cutout position, cable bay, glands and VESA pattern, or turn the 3D model above. After you order we email a dimensioned approval drawing; production starts when you confirm the cutout and the gland positions against your unit. Running a different Vision model or a UniStream panel? Send the model number and we draw the housing to it.
The rest of the Vision series
- Unitronics V130 / V350 HMI housing (2.4 in / 3.5 in, cutout 92 × 92 mm)
- Unitronics V430 HMI housing (4.3 in, 480 x 272, cutout 122.5 × 91.5 mm)
- Unitronics V560 HMI housing (5.7 in, 320 x 240 + keypad, cutout 209 × 126 mm)
- Unitronics V700 HMI housing (7 in, 800 x 480, cutout 193 × 125 mm)
- Unitronics V1040 HMI housing (10.4 in, 800 x 600, cutout 274 × 230 mm)
- Unitronics V1210 HMI housing (12.1 in, 800 x 600, cutout 297 × 228.5 mm)
All models: Unitronics Vision HMI housings.
316L stainless: is it the right grade?
316L adds molybdenum for better resistance to chlorides: the grade for coastal air, brine and chlorinated or caustic washdown. Read the 304 vs 316L guide.
Buying guides
Ratings, sizing, heat and cutouts, before you order
Before you order: HMI enclosures, Cutouts, glands & HMI windows and NEMA 4 vs 4X vs IP66. All guides.
Spotted a wrong number or a broken file? Report a problem with this page.
Nearby sizes
Compare

316L stainless
Stainless Steel HMI Housing for Unitronics V130 / V350 (2.4 in / 3.5 in), Exact Cutout, 304 or 316L

316L stainless
Stainless Steel HMI Housing for Unitronics V430 (4.3 in), Exact Cutout, 304 or 316L

316L stainless
Stainless Steel HMI Housing for Unitronics V700 (7 in), Exact Cutout, 304 or 316L

316L stainless
Stainless Steel HMI Housing for Unitronics V560 (5.7 in), Exact Cutout, 304 or 316L
Checklist · Oct 30, 2026
Remote USB programming access at an HMI enclosure
Plan remote USB programming access with controller limits, cable distance, EMC checks, safe commissioning controls and service-port cutout details.
Read the articleHow-to · Nov 1, 2026
Custom enclosure for a 7 inch touchscreen
Plan a custom enclosure for 7 inch touchscreen modules with realistic depth, battery access, connector clearance, and drawing-ready dimensions.
Read the articleExplainer · Nov 1, 2026
How to verify an HMI NEMA rating claim
An HMI's NEMA 4X or IP66 claim covers its front face only, on panels 1.6–6 mm, tested at 65 gal/min or 100 L/min. Here is how to verify it.
Read the articleExplainer · Nov 2, 2026
Operator station panel classification and marking
A remote operator station with two or more control components is an industrial control panel: give it its own NEMA 4X enclosure, SCCR marking and scope.
Read the articleSelection guide · Oct 28, 2026
Marine electrical enclosure for electronics and a display
Pick the rating, 316L stainless grade, size and display window for a marine electrical enclosure on a boat, plus what to put on the order.
Read the articleTroubleshooting · Oct 30, 2026
Enclosure display window leaks: gasket and fastener checks
Diagnose enclosure display window leaks by checking gasket compression, pooling, window distortion and fastener seals before applying more torque.
Read the articleCustom versionRequest a quote for the Stainless Steel HMI Housing for Unitronics V570 (5.7 in), Exact Cutout, 304 or 316L
Another size, extra holes, your drawing or a quantity quote: quoted by email, built from one piece.Open the quote form
Another size, extra holes, a different cutout, your own drawing or a quantity quote: tell us what you need and attach a drawing if you have one. Custom work is quoted, not priced online, and built from one piece.
- Quote by email Our engineers check your request and reply usually within one business day.
- Drawing You approve a dimensioned drawing before anything is cut.
- 10 business days From that approval to delivery, anywhere in the world.
This HMI housing has an IP65-type front seal with the display installed, manufacturer rated; not UL listed. Once cutouts are added, the rating of the finished enclosure depends on properly rated components and cable glands being installed in every opening.














