Weintek cMT X Series panel cutout dimensions

The Weintek cMT X Series cMT2078X needs a panel cutout of 192 × 138 mm (7.56 × 5.43 in), width by height, and the cMT3152X needs 352 × 279 mm (13.86 × 10.98 in). The table gives the opening for each of the 8 models, the bezel that covers it and the depth the document prints, from the maker's own document, which is linked below. Check the current drawing for your exact catalog number before cutting.

Per model

Weintek cMT X Series cutout dimensions

Weintek cMT X Series: panel cutout per model, width × height
ModelScreenCutout W × H, mmCutout W × H, inBezel W × HDepthAs the document prints itCutout designer
cMT2078X7"192 × 138 mm7.56 × 5.43 in *200.3 × 146.3 mm35 mm192mm [7.559"] × 138mm [5.433"] (data sheet)Lay it out
cMT3072X7"192 × 138 mm7.56 × 5.43 in *200.3 × 146.3 mm35 mm192mm [7.559"] × 138mm [5.433"] (data sheet)Lay it out
cMT3072XH7"192 × 138 mm7.56 × 5.43 in *200.3 × 146.3 mm35 mm192mm [7.559"] × 138mm [5.433"] (data sheet)Lay it out
cMT3072XH27"192 × 138 mm7.56 × 5.43 in *200.3 × 146.3 mm35 mm192mm [7.559"] × 138mm [5.433"] (data sheet)Lay it out
cMT3092X9.7"250 × 192 mm9.84 × 7.56 in *260.6 × 203.1 mm44.5 mm250mm [9.84"] × 192mm [7.56"] (data sheet)Lay it out
cMT3102X10.1"260 × 202 mm10.24 × 7.95 in *271 × 213 mm38 mm260mm [10.24"] × 202mm [7.95"]; corner radius R2mm [R0.08"] (data sheet)Lay it out
cMT3152X15"352 × 279 mm13.86 × 10.98 in *366 × 293 mm51.5 mm352mm [13.86"] × 279mm [10.98"] (data sheet)Lay it out
cMT3162X15.6"384 × 247 mm15.12 × 9.72 in *400 × 263 mm27.6 mm384mm [15.12"] × 247mm [9.72"] (data sheet)Lay it out

* converted at 25.4 mm to the inch from the unit the document prints; the printed figure is in the column "As the document prints it".

Source: Weintek cMT X series data sheets, one per model (each row links its own), read on November 12, 2026. Width is the horizontal side with the terminal mounted in landscape, as the document draws it.

To one scale

The openings side by side

Solid outline: the cutout. Dashed outline: the bezel that has to land on flat door around it, drawn centred on the cutout. Leave the bezel clear of the door stiffeners, the hinge and the latch.

cMT3152XcMT3162XcMT3102XcMT3092XcMT2078X
Door covered by the bezel
ModelBezel wider than the cutout byTaller by
cMT2078X8.3 mm8.3 mm
cMT3072X8.3 mm8.3 mm
cMT3072XH8.3 mm8.3 mm
cMT3072XH28.3 mm8.3 mm
cMT3092X10.6 mm11.1 mm
cMT3102X11 mm11 mm
cMT3152X14 mm14 mm
cMT3162X16 mm16 mm

Totals across both sides. Where the terminal sits centred on its cutout, half of each figure lands on the door at each edge; the drawing in the document shows whether it does.

From the maker's documents

Panel thickness, mounting and front rating

Panel thickness
Installation guides: maximum panel thickness 4.5 mm (cMT2078X, cMT3072X, cMT3072XH, cMT3092X, cMT3102X, cMT3152X); 4 mm (cMT3162X).
Mounting
Brackets and screws in every fastening hole, tightened to 2.6 to 3.9 lbf·in, in a control box with enough stiffness (installation guides).
Front rating, as the maker states it
Data sheets: "UL Type 4X (indoor use only) / NEMA4 / IP66 Compliant Front Panel" (cMT2078X, cMT3072X, cMT3072XH, cMT3072XH2, cMT3092X, cMT3102X); "NEMA4 / IP66 Compliant Front Panel" (cMT3152X, cMT3162X).
Clearance around the terminal
Installation guides: 15 mm top, bottom and sides (cMT2078X, cMT3072X, cMT3072XH, cMT3092X, cMT3152X, cMT3162X); cMT3102X: 15 mm top, 50 mm bottom, 80 mm sides.
Notes
The data sheets print no cutout tolerance. Depth is the overall depth from the specification table. The installation guides print the same cutouts.

A terminal's front rating is its maker's, and it holds only when the terminal is mounted as that document instructs, in an enclosure of a matching type. The assembled rating is limited by the weakest fitting on the enclosure.

In the enclosure

What the opening needs from the door

Room on the door

The bezel is larger than the cutout on every side, and the mounting clips sit behind it. Place the opening so the bezel lands on flat sheet, and keep the depth of the terminal plus the connectors and the cable bend inside the usable depth of the enclosure: each size's usable depth is in the enclosure size chart.

Heat and the seal

A terminal adds its own heat to a sealed box; check the total in the enclosure heat calculator. The gasket seals against the door face, so the cut edge has to be flat and free of burrs. More on door openings in the guide to cutouts, glands and HMI windows.

Need the opening cut for you?

The cutout, cut into a stainless door at the factory.

Send the terminal's model, or enter its cutout and bezel under "My own display" in the cutout designer. We draw the opening on a 304 or 316L stainless enclosure in your size, you approve the drawing, and it is cut before it ships. From one piece. Delivered in 10 business days, anywhere in the world. Counted from your approval of the drawing.

Same maker

Other Weintek series

MT8000 iP and iE Series · every series by screen size

Weintek and the product names on this page are trademarks of their owners. NEMA4 Enclosure is not affiliated with or endorsed by them. The dimensions are quoted from the documents cited for panel layout; a maker can revise a drawing at any time, so check the current document for your exact catalog number before you cut.

Asked and answered

cMT X Series: questions

What is the panel cutout for the Weintek cMT X Series cMT2078X?

192 × 138 mm (7.56 × 5.43 in), width by height, behind a bezel of 200.3 × 146.3 mm. The document prints it as: 192mm [7.559"] × 138mm [5.433"].

What is the panel cutout for the Weintek cMT X Series cMT3072X?

192 × 138 mm (7.56 × 5.43 in), width by height, behind a bezel of 200.3 × 146.3 mm. The document prints it as: 192mm [7.559"] × 138mm [5.433"].

What is the panel cutout for the Weintek cMT X Series cMT3072XH?

192 × 138 mm (7.56 × 5.43 in), width by height, behind a bezel of 200.3 × 146.3 mm. The document prints it as: 192mm [7.559"] × 138mm [5.433"].

What is the panel cutout for the Weintek cMT X Series cMT3072XH2?

192 × 138 mm (7.56 × 5.43 in), width by height, behind a bezel of 200.3 × 146.3 mm. The document prints it as: 192mm [7.559"] × 138mm [5.433"].

What panel thickness does the Weintek cMT X Series mount in?

The document states: Installation guides: maximum panel thickness 4.5 mm (cMT2078X, cMT3072X, cMT3072XH, cMT3092X, cMT3102X, cMT3152X); 4 mm (cMT3162X)..

Can you cut the cMT X Series opening into a stainless enclosure?

Yes. Send the model, or enter its cutout and bezel in the cutout designer under "My own display". We draw the opening on a 304 or 316L stainless enclosure in your size and cut it at the factory after you approve the drawing. Our standard enclosures are rated NEMA 4X / IP66 by the manufacturer; not UL listed; with a terminal installed, the assembled rating is limited by the weakest fitting.