Maple Systems HMI5000 and cMT Series panel cutout dimensions

The Maple Systems HMI5000 and cMT Series HMI5040B needs a panel cutout of 119 × 93 mm (4.69 × 3.66 in), width by height, and the cMT3218XP needs 532 × 340 mm (20.94 × 13.39 in). The table gives the opening for each of the 20 models, the bezel that covers it and the depth the document prints, from the maker's own document, which is linked below. Check the current drawing for your exact catalog number before cutting.

Per model

Maple Systems HMI5000 and cMT Series cutout dimensions

Maple Systems HMI5000 and cMT Series: panel cutout per model, width × height
ModelScreenCutout W × H, mmCutout W × H, inBezel W × HDepthAs the document prints itCutout designer
HMI5040B4.3"119 × 93 mm4.69 × 3.66 in *128 × 102 mm32 mm4.69 x 3.66 [119 x 93] (product page)Lay it out
HMI5043Lv2, HMI5043LBv24.3"119 × 93 mm4.69 × 3.66 in *not printednot printed119 mm x 93 mm (Installation Guide)
cMT2058XH4.3"119 × 93 mm4.69 × 3.66 in *128 × 102 mm32 mm4.69 x 3.66 [119 x 93] (product page)Lay it out
cMT2058XHW4.3"119 × 93 mm4.69 × 3.66 in *128 × 102 mm32 mm4.69 x 3.66 [119 x 93] (product page)Lay it out
HMI5070B7"192 × 138 mm7.56 × 5.43 in *200.4 × 146.5 mm34 mm7.56 x 5.43 [192 x 138] (product page)Lay it out
cMT2078X7"192 × 138 mm7.56 × 5.43 in *200.3 × 146.3 mm35 mm7.56 x 5.43 [192.0 x 138.0] (product page)Lay it out
cMT3072XH37"192 × 138 mm7.56 × 5.43 in *200.4 × 146.5 mm35 mm7.56 x 5.43 [192 x 138] (product page)Lay it out
cMT3072XP7"192 × 138 mm7.56 × 5.43 in *200.3 × 146.3 mm36.9 mm7.56 x 5.43 [192 x 138] (product page)Lay it out
cMT3092Xv29.7"250 × 192 mm9.84 × 7.56 in *260.6 × 203.1 mm44.5 mm9.84 x 7.56 [250 x 192] (product page)Lay it out
cMT3108XH10.1"255 × 185 mm10.04 × 7.28 in *266 × 196 mm43 mm10.04 x 7.28 [255 x 185] (product page)Lay it out
cMT3108XP10.1"255 × 185 mm10.04 × 7.28 in *266 × 196 mm43 mm10.04 x 7.28 [255 x 185] (product page)Lay it out
HMI5100Bv310.1"260 × 202 mm10.24 × 7.95 in *271 × 213 mm36.5 mm10.24 x 7.95 [260 x 202] (product page)Lay it out
cMT2108X210.1"260 × 202 mm10.24 × 7.95 in *271 × 213 mm38 mm10.24 x 7.95 [260 x 202] (product page)Lay it out
cMT3102XV2R10.1"260 × 202 mm10.24 × 7.95 in *271 × 213 mm38 mm10.24 x 7.95 [260 x 202] (product page)Lay it out
cMT2128X12.1"305 × 231 mm12.01 × 9.09 in *317 × 243 mm41 mm12.01 x 9.09 [305 x 231] (product page)Lay it out
cMT2158XV215"352 × 279 mm13.86 × 10.98 in *366 × 293 mm48.2 mm13.86 x 10.98 [352 x 279] (product page)Lay it out
cMT3152XV215"352 × 279 mm13.86 × 10.98 in *366 × 293 mm51.5 mm13.86 x 10.98 [352 x 279] (product page)Lay it out
cMT2166X15.6"384 × 247 mm15.12 × 9.72 in *400 × 263 mm24.9 mm15.12 x 9.72 [384 x 247] (product page)Lay it out
cMT3162XW15.6"384 × 247 mm15.12 × 9.72 in *400 × 263 mm26.1 mm15.12 x 9.72 [384 x 247] (product page)Lay it out
cMT3218XP21.5"532 × 340 mm20.94 × 13.39 in *546 × 354 mm47.5 mm20.94 x 13.39" [532 x 340 mm] (product page)Lay it out

* converted at 25.4 mm to the inch from the unit the document prints; the printed figure is in the column "As the document prints it".

Source: Maple Systems product pages, one per model (each row links its own), and the installation guides for the 4.3 in. units, read on November 12, 2026. Width is the horizontal side with the terminal mounted in landscape, as the document draws it.

To one scale

The openings side by side

Solid outline: the cutout. Dashed outline: the bezel that has to land on flat door around it, drawn centred on the cutout. Leave the bezel clear of the door stiffeners, the hinge and the latch.

cMT3218XPcMT2158XV2cMT2166XcMT2128XHMI5100Bv3cMT3108XHHMI5070BHMI5040B
Door covered by the bezel
ModelBezel wider than the cutout byTaller by
HMI5040B9 mm9 mm
cMT2058XHW9 mm9 mm
cMT2058XH9 mm9 mm
HMI5070B8.4 mm8.5 mm
cMT2078X8.3 mm8.3 mm
cMT3072XH38.4 mm8.5 mm
cMT3072XP8.3 mm8.3 mm
cMT3092Xv210.6 mm11.1 mm
cMT3108XH11 mm11 mm
cMT3108XP11 mm11 mm
HMI5100Bv311 mm11 mm
cMT2108X211 mm11 mm
cMT3102XV2R11 mm11 mm
cMT2128X12 mm12 mm
cMT2158XV214 mm14 mm
cMT3152XV214 mm14 mm
cMT2166X16 mm16 mm
cMT3162XW16 mm16 mm
cMT3218XP14 mm14 mm

Totals across both sides. Where the terminal sits centred on its cutout, half of each figure lands on the door at each edge; the drawing in the document shows whether it does.

From the maker's documents

Panel thickness, mounting and front rating

Panel thickness
Installation guides for the HMI5043Lv2, HMI5043LBv2 and cMT2058XH: maximum panel thickness 4.5 mm. The product pages print none.
Mounting
Panel mount. The installation guides for the 4.3 in. units call for a control box with enough stiffness, every fastening hole used with the provided brackets and screws, tightened to 2.6 to 3.9 lbf·in.
Front rating, as the maker states it
Product pages: "IP65 compliant front panel" and NEMA4 (HMI5070B); "IP66 Compliant Front Panel" and NEMA4 (cMT2058XHW, cMT2166X, cMT3092Xv2, cMT3108XH, cMT3162XW, cMT3218XP), most of them also "UL Type 4X (indoor use only)". Read the page for your model; the rows differ.
Clearance around the terminal
Installation guides for the 4.3 in. units: 15 mm top, 50 mm bottom, 15 mm sides, along the overlay.
Notes
The product pages print the cutout as inches, then millimetres in brackets, without naming which figure is the width; the first is given here as the width, the order the same pages use for the overall dimensions (W x H x D). No cutout tolerance or corner radius is printed. Depth is the overall depth of the unit. The HMI5043Lv2 and HMI5043LBv2 row comes from the installation guide, which prints the cutout only; the cMT2058XH guide prints the same cutout as its product page.

A terminal's front rating is its maker's, and it holds only when the terminal is mounted as that document instructs, in an enclosure of a matching type. The assembled rating is limited by the weakest fitting on the enclosure.

In the enclosure

What the opening needs from the door

Room on the door

The bezel is larger than the cutout on every side, and the mounting clips sit behind it. Place the opening so the bezel lands on flat sheet, and keep the depth of the terminal plus the connectors and the cable bend inside the usable depth of the enclosure: each size's usable depth is in the enclosure size chart.

Heat and the seal

A terminal adds its own heat to a sealed box; check the total in the enclosure heat calculator. The gasket seals against the door face, so the cut edge has to be flat and free of burrs. More on door openings in the guide to cutouts, glands and HMI windows.

Need the opening cut for you?

The cutout, cut into a stainless door at the factory.

Send the terminal's model, or enter its cutout and bezel under "My own display" in the cutout designer. We draw the opening on a 304 or 316L stainless enclosure in your size, you approve the drawing, and it is cut before it ships. From one piece. Delivered in 10 business days, anywhere in the world. Counted from your approval of the drawing.

Maple Systems and the product names on this page are trademarks of their owners. NEMA4 Enclosure is not affiliated with or endorsed by them. The dimensions are quoted from the documents cited for panel layout; a maker can revise a drawing at any time, so check the current document for your exact catalog number before you cut.

Asked and answered

HMI5000 and cMT Series: questions

What is the panel cutout for the Maple Systems HMI5000 and cMT Series HMI5040B?

119 × 93 mm (4.69 × 3.66 in), width by height, behind a bezel of 128 × 102 mm. The document prints it as: 4.69 x 3.66 [119 x 93].

What is the panel cutout for the Maple Systems HMI5000 and cMT Series cMT2058XHW?

119 × 93 mm (4.69 × 3.66 in), width by height, behind a bezel of 128 × 102 mm. The document prints it as: 4.69 x 3.66 [119 x 93].

What is the panel cutout for the Maple Systems HMI5000 and cMT Series HMI5043Lv2, HMI5043LBv2?

119 × 93 mm (4.69 × 3.66 in), width by height. The document prints it as: 119 mm x 93 mm.

What is the panel cutout for the Maple Systems HMI5000 and cMT Series cMT2058XH?

119 × 93 mm (4.69 × 3.66 in), width by height, behind a bezel of 128 × 102 mm. The document prints it as: 4.69 x 3.66 [119 x 93].

What panel thickness does the Maple Systems HMI5000 and cMT Series mount in?

The document states: Installation guides for the HMI5043Lv2, HMI5043LBv2 and cMT2058XH: maximum panel thickness 4.5 mm. The product pages print none..

Can you cut the HMI5000 and cMT Series opening into a stainless enclosure?

Yes. Send the model, or enter its cutout and bezel in the cutout designer under "My own display". We draw the opening on a 304 or 316L stainless enclosure in your size and cut it at the factory after you approve the drawing. Our standard enclosures are rated NEMA 4X / IP66 by the manufacturer; not UL listed; with a terminal installed, the assembled rating is limited by the weakest fitting.