Yes — stack them, but pass the conductors through one 4 in [102 mm] chase nipple instead of a square hole. Cut a matched round hole in the bottom of the upper trough and the top of the lower one. Set the fitting with a locknut and an insulated bushing on each face, and hold the two bodies together with bolts or self-sealing rivets. The run between the bodies measures under 2 in [51 mm], so two NEC short-run rules work in your favor: 60 % fill allowed in the nipple, and no ampacity derating for runs of 24 in [610 mm] or less. Ratings here are manufacturer ratings throughout — NEMA 3R on the troughs, NEMA 4X on our boxes — and ours are not UL listed.
What counts as a listed pass-through between the two troughs?
One chase nipple through matched holes: it is a short threaded fitting with a locknut on each face, the NEC lets a nipple that size or smaller run at 60 % fill up to the length limit, and a single fitting legitimately carries every conductor between the troughs.
A chase nipple exists for exactly this box-to-box transition. The shoulder seats on the upper wall, a locknut pulls down on the lower wall, and an insulated bushing on each end protects the insulation. That bushing is part of the rule rather than an upgrade: the NEC calls for an insulating fitting or bushing wherever conductors 4 AWG or larger enter an enclosure, and 2/0 sits five sizes above that threshold. Cutting for the fitting means a 4½ in [114 mm] hole in each wall — the thread's outside diameter. One fitting for everything is the same logic as running two cables through one gland: fewer holes, fewer edges, one seal to defend.
Does one chase nipple carry three 2/0 runs?
Yes, with margin: three runs of three 2/0 THHN plus twelve 12 AWG control wires total 2.04 in² [1316 mm²] of conductor, which is 17 % of the bore against the 60 % nipple allowance of 7.3 in² [4710 mm²].
Take the case this question always brings. Call a run three conductors — L1, L2, L3 of one feeder — so three runs are nine 2/0. Each 2/0 THHN occupies about 0.209 in² [135 mm²] of cross-section in the NEC's conductor-area tables; each 12 AWG about 0.013 in² [8 mm²]. The bore holds about 12.1 in² [7800 mm²] rigid and 12.7 in² [8190 mm²] at EMT wall, so run the conservative number.
| What passes through | Count | Each | Total |
|---|---|---|---|
| 2/0 THHN, 0.516 in [13 mm] OD | 9 | 0.209 in² | 1.88 in² |
| 12 AWG THHN control | 12 | 0.013 in² | 0.16 in² |
| Everything in the one nipple | 21 | — | 2.04 in² |
| 60 % allowance on the bore | — | — | 7.3 in² |
If a run means one single 2/0, the arithmetic only gets easier: three conductors total 0.63 in² [405 mm²], 5 % fill. The straight, unbent pass is the quiet benefit of stacking — with no bend in the run there is no sidewall pressure to compute and no jam ratio worth worrying about.
Do you have to derate ampacity for the pass-through?
No: the NEC exempts raceway runs of that length or less from the ampacity adjustment table, and the nipple between two stacked troughs spans two walls and a gasket in under 2 in [51 mm], nowhere near the limit.
That exemption is why stacking works for big conductors, so run the counterfactual once. Nine power conductors plus twelve current-carrying control wires are 21 current-carrying conductors, which lands in the 21–30 bracket of the NEC adjustment table at 45 %. A 2/0 copper conductor rated 175 A at 75 °C in the NEC's ampacity table would then come out at 175 × 0.45 = 79 A. Start instead from the 195 A at 90 °C that the insulation allows and you get 88 A. Keep the transition short and both of those numbers stay irrelevant.
The troughs themselves run on the NEC's wireway rules, which are gentler. Adjustment starts only above 30 current-carrying conductors in one cross-section, and 21 is under it. Fill in a wireway is capped at 20 % of the cross-section where conductors pass through, and at 75 % where you splice or tap at that section.
Can you cut one square opening through both troughs?
You can, and face-to-face square openings have passed field inspection, but the numbers decide it: leave 2 in [51 mm] of flat steel on every side of the cut, so a 5 x 5 in [127 x 127 mm] opening needs a 9 in [229 mm] wide trough, and cover every cut edge.
On a 6 x 6 in [152 x 152 mm] trough that land rule caps the opening at 2 x 2 in [51 x 51 mm] — big enough for the conductor bundle, with no steel left for a gasket that stops wind-driven rain. Where the width allows it, snap armored edge guard over all four cut edges; that is your insulating protection for conductors 4 AWG and larger. Lay a 1/8 in [3 mm] closed-cell gasket strip inside the fastener line, and let the interface sit shielded between the two bodies so rain never strikes it directly. The trough makers hold the 3R rating across in-line section joints with a wrap-around connector; a vertical stack with field-cut openings is your design, and the rating you keep is the one you can defend. What NEMA rating a panel keeps after you cut it and the cutouts and glands guide cover the same fight on enclosures.
How do you fasten and bond the two troughs together?
Bolts and nuts, or self-sealing rivets: 1/4 in [6 mm] machine bolts with nuts and lock washers on a 6 in [152 mm] pattern, or 3/16 in [5 mm] self-sealing rivets that seal their own holes; sheet-metal screws give you neither the clamping nor the bonding path the NEC accepts.
The two locknuts on the nipple bond the bodies through the fitting. Add a second path you can put a meter on: an equipment grounding jumper between the ground lugs, sized from the overcurrent device ahead of it under NEC Table 250.122 — 6 AWG copper for a 200 A feeder. The grounding and bonding guide carries the full picture, including NEC 250.12's call for paint and coatings stripped from the contact surfaces where a joint has to carry fault current.
How do you build the stack, step by step?
Follow the nipple route: it is one 4½ in [114 mm] hole per wall, one fitting, two locknuts, two bushings, and about an hour of work from marking to final tightening on a two-trough stack.
- Dry-fit the troughs face to face and mark one common center, at least 2 in [51 mm] from every formed edge, in the bottom of the upper body and the top of the lower one.
- Cut a 4½ in [114 mm] hole in each wall with a hole saw or knockout punch, then deburr both faces so the gasket sits on flat steel.
- Stick a 1/8 in [3 mm] closed-cell gasket strip to the mating face, inside the fastener line, when the stack lives outdoors.
- Slide the chase nipple through both holes: shoulder up top, locknut and insulated bushing inside the upper trough, locknut and insulated bushing inside the lower one.
- Fasten the bodies with 1/4 in machine bolts, nuts and lock washers on a 6 in [152 mm] pattern — or 3/16 in self-sealing rivets — working from the center outward so the gasket compresses evenly.
- With the circuits dead and locked out, pull the nine 2/0 and twelve 12 AWG through in one pass with pulling compound; the straight, short run has no bend to fight.
- Tighten both locknuts wrench-tight, re-count the conductors, and re-run the fill number: 2.04 in² [1316 mm²] against the 7.3 in² [4710 mm²] allowance is 28 % of what is permitted.
What checks prove the stack is sound?
Four checks close it out, one number each: 28 % of the nipple allowance used, a short run on the tape, a fraction of an ohm body to body, and a dry joint after the first storm.
- Fill: recompute both limits — 2.04 in² [1316 mm²] of conductor against the 7.3 in² [4710 mm²] nipple allowance, and against 20 % of the trough's cross-section where the conductors pass.
- Derating: measure the run between bodies; bolted face to face it reads about 2 in [51 mm]. Anything you add that lengthens it past the short-run limit brings the 45 % bracket with it.
- Bonding: a low-ohm meter between the two bodies reads fractions of an ohm through the locknuts and the jumper together.
- Weather: after the first hard rain, open the joint and look. 3R sheds rain and sleet and shrugs off ice, so water at the interface points at the gasket or the fastener holes — start with the outdoor entry repair checks, and for the trough's own top entries, a hub beats a sealing locknut.
When does one enclosure beat two stacked troughs?
Order one enclosure instead when anything terminates: a single 30 x 24 x 12 in [762 x 610 x 305 mm] stainless box replaces the whole stack, and 2/0 landing on terminals inside it needs the bending space NEC 312.6 sets by wire size.
Two stacked troughs win when wire only passes through — lay-in conductors at two levels, rain exposure, nothing landing anywhere. One box wins when the conductors splice, terminate, or share the space with devices. A box gives you a backplate, a door, and terminals with room to bend; the enclosure sizing guide has the bending-space tables. And when a washdown hose comes anywhere near, 3R was the wrong rating from the start — that is Type 4 or 4X territory, and the 3R versus 4 comparison draws the line. Our 30 x 24 x 12 in 304 wall-mount enclosure measures 30 x 24 x 12 in [762 x 610 x 305 mm] outside with close to 29.9 x 23.9 x 11.9 in of usable inside space. When no catalog shape fits the spot, a custom one-piece enclosure with every cutout drawn before the first hole is drilled — delivered in 10 business days from your approval of the drawing — beats field fabrication in a tight space.
Enclosures in this article
| Enclosure | Material | Outside H x W x D / display | Rating |
|---|---|---|---|
| 30 × 24 × 12 in | 304 stainless | 30 x 24 x 12 in | Rated NEMA 4X / IP66 by the manufacturer; not UL listed |
Questions
Can you use three 2 in chase nipples instead of one larger fitting?
Yes. Give each feeder its own 2 in [51 mm] nipple: three 2/0 per fitting is 0.63 in² [405 mm²] in a 3.4 in² [2190 mm²] bore, about 18 % fill against the 60 % allowance. Keep each run at or under the 24 in [610 mm] derating limit. Put an insulated bushing on both ends of every nipple, because 2/0 sits well above the 4 AWG size that triggers the insulating-fitting rule.
Does the joint between stacked 3R troughs need to be watertight?
No. NEMA 3R covers rain, sleet and ice, and the interface sits horizontal and shielded between the two bodies, so a 1/8 in [3 mm] closed-cell gasket with self-sealing rivets is the standard fix. You need true sealing only where a hose touches the equipment, and that is Type 4 or 4X work, not 3R.
Can you stack a third trough the same way?
Yes. Each interface gets its own nipple, and the short-run derating exemption is measured per run, so two joints are as clean as one. Watch the middle cross-section instead: all 21 conductors of the worked example pass through it at once. 2.04 in² [1316 mm²] stays well under the 7.2 in² [4650 mm²] that 20 % fill allows in a 6 x 6 in [152 mm] wireway.
How much spare capacity does the big nipple leave for future conductors?
About 5.3 in² [3400 mm²]. The 60 % allowance on a 12.1 in² [7800 mm²] bore is 7.3 in² [4710 mm²], and the worked example uses 2.04 in² [1316 mm²], which is room for roughly 25 more 2/0 conductors on paper. The trough's own 20 % fill limit usually stops you first, so re-run the wireway number before the nipple number.