Sealed enclosure for a fanless edge computer in dust

Put the computer in a sealed stainless box rated NEMA 4X / IP66 by the manufacturer and give it no vents. The walls do the cooling: at 3.7 W/m²K, a 16 x 12 x 8 in stainless box holds a 40 W device about 20 C above a 35 C ambient, so size the wall area against the computer's ambient limit before ordering.

NEMA4 Enclosure engineering team · Published November 23, 2026 · 7 min read

Short answer: seal the box and let its walls cool the computer. A fanless edge computer carries no dust rating of its own, so the enclosure takes the job: a stainless box rated NEMA 4X / IP66 by the manufacturer, no vents, no fan-filter. A 40 W computer in a 16 x 12 x 8 in [400 x 300 x 200 mm] stainless box runs about 20 C above a 35 C ambient, so size the wall area before you order. The sections below give you the rating, the heat arithmetic and the order line.

The box carries the dust rating, not the computer

Take the lid off a fanless edge computer and you find aluminium cooling fins, open connector slots and a bare PCB. Nothing on it is sealed. Its datasheet's industrial temperature range describes the silicon and the storage parts, and it says nothing about dust. In fine, abrasive dust those fins clog first, the still-air film thickens, and the junction temperatures climb.

That is why the ingress question belongs to the enclosure. IEC 60529 defines the code, the enclosure maker tests to it, and the printed result covers everything inside. For the ventilated case, a computer with its own fan behind a filter, the trade-off is different, and the dusty shop floor comparison works it through. When the computer is fanless there is no airflow to filter, so the clean answer is a fully sealed box with no air exchange at all.

What IP66 and Type 4X each add

IEC 60529 writes the code in two digits. First digit 6 means dust-tight: no dust ingress at all in the chamber test. First digit 5 means dust-protected, which admits some dust as long as it cannot interfere with operation. A site with an edge computer in it wants the 6. The full digit-by-digit breakdown is in the IP rating chart guide.

Second digit 6 adds powerful water jets: a 12.5 mm nozzle delivering 100 L/min from every practical direction. That covers outdoor rain and washdown, which open computer ports could never survive on their own.

NEMA 250's Type 4X adds corrosion on top of Type 4: the 4X test sequence includes another 200 hours of salt spray alongside an AISI 304 stainless specimen. Dust alone does not ask for it; salt air, washdown chemicals or road spray do. The NEMA 4 vs 4X vs IP66 guide compares the test behind each marking.

Both markings on our boxes are manufacturer ratings: they are rated NEMA 4X / IP66 by the manufacturer; not UL listed. A project specification that requires a listed enclosure needs a listed product from whoever supplies it.

Once it is sealed, heat is the whole game

A sealed box wins the dust fight and changes the cooling problem. In free air, the computer's fins shed heat to moving air. Inside a sealed box the air is still, the fins warm a small pocket of air, and the only path out is conduction and radiation through the walls. That path follows one formula:

Q = k x A x dT

Here k is the wall's heat transfer coefficient: 3.7 W/m²K for stainless, the accepted value this site's sizing method uses. A is the outside surface area in square metres, dT is the temperature rise in kelvin, and Q is the heat the computer dumps, in watts. You read Q from the datasheet, you pick A when you pick the box, and dT is what is left.

Two live articles go deeper on the pieces: how to size a non-ventilated stainless enclosure by heat dissipation and enclosure surface area by mounting type.

A 40 W computer in a 16 x 12 x 8 in box at 35 C ambient

The inputs for this example, and where each one comes from:

  • Heat: 40 W, an assumed figure for the example. Replace it with the datasheet's rated power for the computer; a fanless device turns nearly all of its draw into heat.
  • Box: 16 x 12 x 8 in [400 x 300 x 200 mm] outside, a size inside the stainless wall-mount range.
  • Coefficient: 3.7 W/m²K for stainless, the accepted value this site's sizing method uses.
  • Ambient: 35 C (95 F), a warm shop floor or a shaded outdoor wall in summer.

First the surface area. For a rectangular box, A = 2 x (H x W + H x D + W x D):

A = 2 x (16 x 12 + 16 x 8 + 12 x 8) = 2 x (192 + 128 + 96) = 2 x 416 = 832 in² = 0.537 m²

Then the rise, rearranged from the formula:

dT = Q / (k x A) = 40 W / (3.7 W/m²K x 0.537 m²) = 40 / 1.99 = 20 K

The air inside sits at 35 + 20 = 55 C.

Now the wall-mount correction. The feet hold the box off the wall, so part of the back face still rejects heat. Treat it conservatively as fully blocked: the back face is 16 x 12 = 192 in² = 0.124 m², leaving A = 0.537 - 0.124 = 0.413 m². Then dT = 40 / 1.53 = 26 K, and the interior sits near 61 C. A real box on feet lands between 55 and 61 C.

The scaling is easy to carry: every 10 W off the load drops the rise about 5 K in this box, and every 10 C off the ambient drops the interior 10 C.

The decision comes from the computer's own ambient rating, which you read off its datasheet. Many industrial fanless computers carry a 50 C ambient limit and some carry 60 C. Against a 50 C limit, this box fails the 35 C example: 55 to 61 C is above it. Against 60 C it holds, with margin at the low end of the wall-mount correction and little at the high end.

When the rise lands above the limit

Three moves keep the seal while pulling the interior temperature down:

  1. Step up the box. A 20 x 16 x 8 in [500 x 400 x 200 mm] box gives A = 2 x (20 x 16 + 20 x 8 + 16 x 8) = 2 x 608 = 1,216 in² = 0.784 m². The 40 W rise becomes 40 / 2.90 = 14 K, so the interior lands about 49 C at 35 C ambient: under a 50 C limit by the full-area method, and marginal at about 54 C once the blocked back face is counted.
  2. Couple the fins to the wall. Thermal pads between the computer's finned face and the enclosure wall turn the box itself into the heatsink and skip the still-air pocket entirely. The sealed conductive cooling article works that path in detail.
  3. Move heat with a sealed cooler. An air-to-air heat exchanger or an enclosure air conditioner rejects heat without opening the box. The seven-option cooling comparison ranks them by load and ambient, and the hot-ambient sealed-box article covers this case specifically.

Outdoors, add the sun: direct sunlight on the wall can add more heat than the computer does, and the outdoor enclosures guide treats it as the largest outdoor load. A sun shade cuts it before you touch the box size.

304 or 316L at a dusty site

Let what travels with the dust decide. Dry plant dust, grain flour or polymer powder inside a dry inland building suits 304: the dust itself does not attack stainless. Add coastal air, road salt, fertiliser or chlorinated washdown, and 316L earns its molybdenum, because 304 pits under chloride deposits even at room temperature while 316L resists them. Both grades share a chloride stress-corrosion ceiling near 60 C (140 F), so a hot box near salt wants 316L and the larger size. The coastal-air article works that site case through.

Entries, feet and cutouts

Every penetration is a dust door. Enter through the bottom wall, size each hole to the gland's specified range for that cable's outside diameter, and fit a gland the enclosure maker documents for the rating. Spare holes get rated plugs, not tape. The cutouts, glands and windows guide walks the hole-by-hole decisions.

Ordering the cutouts with the box keeps the story simple: the holes arrive deburred at the positions on the drawing you approved, so no field drilling leaves a burr in the gasket line. Mounting feet attach outside the sealed volume and leave it intact. Where a signal crosses the wall as a board-to-board or edge connector instead of a cable, the sealed edge connector article covers the hardware.

What to put on the order

Order line What to specify Why
Material 304 stainless; 316L within reach of salt, road spray or chlorinated washdown Dust is inert; the chlorides around it are not
Size 16 x 12 x 8 in [400 x 300 x 200 mm] minimum for 40 W; 20 x 16 x 8 in for a 50 C-rated computer at 35 C ambient The worked example above
Rating Manufacturer-rated NEMA 4X / IP66; not UL listed Dust-tight, jet-resistant, corrosion-tested
Cutouts None, or bottom-wall holes sized to each cable's outside diameter for rated glands Every hole is a dust door
Door and panel Hinged gasketed door, removable mounting plate Wiring and service without unbolting the box
Delivery 10 business days, counted from the order; with custom cutouts, from your drawing approval The standing promise

Browse the stainless wall-mount range in the size finder or start from the NEMA 4X enclosures page. Send the computer's rated power with the enquiry and the size can be confirmed against the arithmetic before anything is cut.

Catalog dimensions to compare

Compare these catalog dimensions with your component layout. Open each enclosure for its rating, material and usable space, then check those specifications against your application.

EnclosureMaterialOutside H x W x D / displayRating
16 × 12 × 8 in304 stainless16 x 12 x 8 inRated NEMA 4X / IP66 by the manufacturer; not UL listed
20 × 16 × 8 in304 stainless20 x 16 x 8 inRated NEMA 4X / IP66 by the manufacturer; not UL listed
12 × 10 × 6 in304 stainless12 x 10 x 6 inRated NEMA 4X / IP66 by the manufacturer; not UL listed
16 × 14 × 8 in304 stainless16 x 14 x 8 inRated NEMA 4X / IP66 by the manufacturer; not UL listed

Questions

Does a fanless edge computer need IP67 to keep dust out?

No. Dust is the first digit of the IEC 60529 code: IP6X means dust-tight, tested in a circulating dust chamber with no ingress allowed. IP66 gives dust-tight plus second-digit 6 water jets, so a dusty site that also sees rain or washdown is covered in one code. IP67 adds temporary immersion at 1 m for 30 min, which a dry dusty plant never asks for.

How much heat can a sealed stainless enclosure wall reject?

Use Q = 3.7 x A x dT in watts, with A in square metres and dT in kelvin; 3.7 W/m²K is the combined convection and radiation coefficient this site uses for stainless. A 0.537 m² box at a 20 K rise rejects 40 W. Painted steel at 5.5 W/m²K rejects more per square metre, but a dusty site usually wants stainless for cleaning.

Can I add a filter fan to a dust-tight enclosure?

You can, and you change the decision. A fan-filter keeps air moving but the assembly's rating becomes the filter's rating, and in fine dust the filter clogs, airflow falls and the heat rise climbs. That ventilated path suits coarser dust and a computer with its own fan. The sealed box keeps IP6X for the fine, abrasive dust around a fanless computer.

Does the wall behind a wall-mount enclosure count as cooling surface?

Partly. Treat it conservatively as fully blocked and a 16 x 12 x 8 in box loses 192 in², about 0.124 m² of its 0.537 m², moving the 40 W rise from 20 K to 26 K. A real box on feet, which keeps most of the back face clear of the wall, lands between the two.

Can I drill my own cable-entry holes?

Yes, in the bottom wall, with the right hardware: a hole matched to the cable and a gland the enclosure maker documents for the rating, and rated plugs in any spares. Ordering the cutouts with the box is simpler: they arrive deburred at the drawing positions, delivered in 10 business days from your drawing approval.

304 or 316L stainless for a dusty plant?

304 for dry, inland dust in a shed or plant room: the dust itself is inert. Choose 316L when the dust arrives with chlorides such as coastal air, road salt or chlorinated washdown, because 304 pits under chloride deposits even at room temperature. At a hot salty site, 316L with the larger size also buys margin against the stress-corrosion ceiling described in the body.

Checklist before you order

Specify it once, built to your drawing

  • Environment and NEMA type: Type 1, Type 3R, Type 4, Type 4X, Type 6P, Type 12, Type 13 (manufacturer ratings, not UL listed)
  • Material: 304 stainless steel, 316L stainless steel, Powder-coated carbon steel, Aluminum, Polycarbonate, Fiberglass (FRP)
  • Size: inside or outside height, width and depth, with the depth your deepest component needs
  • Cutouts, glands and windows, dimensioned from one datum on each face
  • Mounting and access: wall, pole or stand, hinge side, mounting panel
  • Quantity: from one piece

Delivered in 10 business days, anywhere in the world. Counted from your order; for custom work, from your approval of the drawing.

Build it from 16 × 12 × 8 inRequest a custom quote

Check the heat load in the calculator · NEMA 4X enclosures: sizes for this job