Short answer: a pair of lamps matches the resistor only after the filaments glow, and the chopper does its worst work before that. Two 75 W, 120 V lamps in parallel read about 96 Ω hot but roughly 10 Ω cold. At a 400 V DC bus the braking transistor meets 40 A on the first pulse against the 4 A it was built for — ten to one, held for the tens of milliseconds a filament takes to heat. The failure is explosive. Order the braking load from your drive's published minimum braking resistance instead; the worked example below assumes that bus and a 100 Ω minimum, and your drive's manual carries both real numbers.
What the chopper switches
When you ramp a drive down fast, the motor becomes a generator and pushes energy back into the drive's DC bus. The bus voltage climbs until the drive switches a resistor across it through one transistor, the braking chopper, and duty-cycles that resistor to hold the voltage steady. The load you choose sets the current in that transistor on every pulse.
The resistor never sees the motor frequency or the 230 V supply; it sees rectified bus voltage. At the instant the transistor closes, the current is I = Vbus / R and the power in the load is P = Vbus² / R, both taken with the resistance present at that instant. On a 230 V class drive the chopper begins to conduct near 400 V DC; your manual prints the threshold, and every number below uses that value.
Drive makers size that transistor for the current their own minimum braking resistance draws, with modest margin. Any load that draws more, for longer than a few microseconds, sits outside the design point however neatly it matches on paper once hot.
One habit worth keeping whenever the resistor comes off: the DC bus holds its charge after the supply is cut. Isolate, wait out the drive's discharge time, and measure across the bus terminals before you touch the wiring.
Hot resistance is the wrong number
The lamp argument runs on the hot figure. A 75 W, 120 V lamp has a hot resistance of 120² / 75 = 192 Ω, so two in parallel give 96 Ω — near enough to a 100 Ω braking resistor to look convincing. At 120 V the pair draws 1.25 A and shines like a 150 W heater.
That 96 Ω exists only with the filaments white hot. Cold, a tungsten filament measures about one-tenth of its hot value, the same behaviour behind lamp inrush; lamp-driver application notes put the switch-on current near ten times the running current. The cold pair presents roughly 10 Ω.
The resistance that sizes the chopper is the lowest value the transistor ever sees. For any filament load that is the cold value, at the first instant of the first pulse — exactly the number the hot-resistance match conceals.
Two 75 W lamps on the bus, worked through
Inputs, each with its source:
| Input | Value | Where it comes from |
|---|---|---|
| Braking load | two 75 W, 120 V lamps in parallel | the improvised load |
| Hot resistance | 192 Ω each, 96 Ω the pair | from the ratings, V² / P |
| Cold resistance | about 10 Ω the pair | one-tenth of hot, the cold-filament ratio |
| Chopper threshold | 400 V DC | assumption; read yours from the manual |
| Minimum braking resistance | 100 Ω | assumption for a 1.5 kW class drive; the manual's braking table has the real value |
The rule in words: current at switch-on is bus voltage divided by the resistance present at that instant — the cold value, because the filament is cold then. Power is bus voltage squared over the same resistance.
- Design point:
400 V / 100 Ω = 4 A— the current the chopper transistor was sized around. - Hot pair:
400 / 96 = 4.2 A, and400² / 96 = 1,667 W. - Cold pair:
400 / 10 = 40 A, and400² / 10 = 16,000 W— 16 kW into parts rated 75 W.
Result: 40 / 4 = 10 times the design current, sustained for the tens of milliseconds the filaments need to warm. Even hot, the 96 Ω pair sits below the assumed 100 Ω minimum, so the substitution misses spec before the cold-filament argument even starts.
Decision: measure any candidate load cold with an ohmmeter and hold it at or above your drive's minimum braking resistance; anything below that threshold stays off the order. With a ±10 % tolerance resistor, order at least 100 / 0.9 = 111 Ω for a 100 Ω minimum. One drive maker's dynamic braking calculator publishes that minimum without the resistor's own tolerance and requires third-party resistors to be larger than it.
Why the transistor dies first
A power transistor lives inside its safe-operating-area curve, and the allowance collapses as pulses lengthen. A device that carries 40 A for 10 µs holds a fraction of that at 10 ms, and filaments take tens of milliseconds — on a slow stop, a couple of hundred — to reach temperature. The overcurrent lands in exactly the window where the part is weakest.
At 16 kW the fault clears itself violently. On small modern drives the chopper shares one moulded package with the input bridge and the six output switches, so its rupture takes the bridge and the output stage with it. Several resistors and diodes leave the board at once, and the lamps' 75 W rating never slows the sequence, because the transistor is the weakest part in the series path.
What to order instead
Put four things on the order:
- Resistance — at or above the drive's published minimum braking resistance, with the tolerance paid for. Use
R_min / 0.9for a ±10 % part. - Continuous watts — from the average heat of your duty cycle, not from the motor's kW. A longer ramp spreads the same kinetic energy over more seconds; it lowers the watts during the stop but leaves the total energy to absorb.
- Pulse energy — from your worst stop at full inertia, checked separately from the average. A long ramp is not automatically a light duty.
- Mounting — start from sizing and mounting a braking resistor in a VFD enclosure for clearances, and estimating enclosure thermal resistance from the heat load for what the added watts do to the box.
The enclosure side matters as soon as the resistor shares a box with the drive. Braking resistor overload from a hot panel shows what happens when that heat has nowhere to go, and a VFD enclosure's rating, size and cooling for one drive walks the whole decision. A resistor bank usually pushes you to a deeper body. Our custom enclosures take your mounting layout and every cutout on the drawing, delivered in 10 business days from your approval of the drawing. The enclosure selector shortlists by the space you need. Those stainless boxes are rated NEMA 4X / IP66 by the manufacturer and not UL listed.
Series lamps and heater elements
Series connection fixes the voltage problem and keeps the fatal one: both filaments start cold. A cold series pair reads about 40 Ω, and that leaves the chopper carrying 400 / 40 = 10 A — two and a half times a 4 A design point. Once warm the pair is about 384 Ω, barely over 1 A of braking, and the first filament to open mid-stop removes braking entirely and sends the bus to the overvoltage trip.
Series lamps do have a legitimate job on an AC supply. Two 120 V lamps in series across 120 V run each filament at about 60 V, cool and long-lived, which is why the arrangement survives as an anti-condensation heater inside panels. That duty, at a fraction of rated current, tells you nothing about chopper duty on the DC bus.
Heater elements are the nearest honest cousin, because an element holds close to its nameplate resistance hot or cold. Use one when the drive maker's documents accept the part, once its cold resistance clears the minimum with margin and its pulse rating covers your worst stop.
Catalog dimensions to compare
Compare these catalog dimensions with your component layout. Open each enclosure for its rating, material and usable space, then check those specifications against your application.
| Enclosure | Material | Outside H x W x D / display | Rating |
|---|---|---|---|
| 60 × 36 × 16 in | 304 stainless | 60 x 36 x 16 in | Rated NEMA 4X / IP66 by the manufacturer; not UL listed |
| 48 × 36 × 16 in | 304 stainless | 48 x 36 x 16 in | Rated NEMA 4X / IP66 by the manufacturer; not UL listed |
| 60 × 36 × 12 in | 304 stainless | 60 x 36 x 12 in | Rated NEMA 4X / IP66 by the manufacturer; not UL listed |
| 16 × 12 × 8 in | 304 stainless | 16 x 12 x 8 in | Rated NEMA 4X / IP66 by the manufacturer; not UL listed |
Questions
What is the lowest resistance a braking load may have?
The minimum braking resistance in your drive's manual, set by the current its chopper transistor can carry. Read that figure as a floor before tolerance: with a ±10 % part, order at least 100 / 0.9 = 111 Ω against a 100 Ω minimum. Design current is simply bus voltage over that resistance — 4 A per 100 Ω at our example bus, and scale it if your drive's threshold sits elsewhere.
Do two lamps in series work any better?
No. Series raises the resistance, but both filaments still start cold, so the pair presents roughly 40 Ω and carries 10 A at switch-on — two and a half times the 4 A design point. Once warm the pair climbs to about 384 Ω, barely over 1 A of braking, so the load fades exactly when you need it. And the first filament to open mid-stop removes braking completely and sends the bus to the overvoltage trip.
Can a strip heater serve as a braking resistor?
Only when the drive maker's documents accept the part, or when the element measures safely above the drive's minimum braking resistance while cold. A heater element holds close to its nameplate resistance hot or cold, which is why heater loads can work where lamp loads destroy the chopper. Its pulse-energy rating, insulation and heat removal still have to cover your worst stop; wattage alone never settles it.
How do you test a braking circuit safely?
Bolt the drive down, fit the correct resistor at or above the manual's minimum, and put the cover on before you apply power. Run a stop from full speed with the real load inertia and watch the DC bus voltage on the drive's display: it should rise to the chopper threshold printed in the manual and hold there for the whole ramp. Before you touch anything afterward, isolate and measure across the bus terminals, which stay charged after power-off.