Size the enclosure around the installed PC/104 assembly, not just the board outline. Include every mating plug, routed cable, standoff and fastening tool in the fit check. Then reserve space for a defined expansion configuration. A board format establishes mechanical interfaces, but it does not guarantee that future connectors or cooling hardware will fit your enclosure.
Gather the mechanical drawings
Start with the applicable form-factor specification and the drawings for every board in the proposed stack. Obtain current documents from the form-factor organization and each board manufacturer.
The familiar 3.55 × 3.775 in [90 × 96 mm] PC/104 footprint is a starting reference, not the installed envelope. Related formats can use different bus connectors, stacking arrangements and mechanical requirements. Confirm whether each board follows PC/104, PC/104-Plus, PCI-104, PCI/104-Express or PCIe/104 requirements before combining dimensions.
The form-factor specification establishes the applicable board geometry, mounting pattern and stacking interface. Board-specific drawings establish the actual component heights, peripheral connectors and permitted assembly clearances. Neither document replaces the other.
Collect these items before choosing enclosure dimensions:
- Dimensioned board outlines, mounting holes and connector locations.
- Component-height limits above and below each board.
- Required stack order, spacers and inter-board connector engagement.
- Drawings for mating plugs, backshells and cable assemblies.
- Cable minimum bend radii and any required straight length behind connectors.
- Mounting hardware, cooling hardware and grounding connections.
- A named future configuration or explicit dimensional expansion limits.
Keep connector part numbers and drawing revisions with the layout. A replacement cable can change the envelope even when the board stays unchanged.
For the broader board-to-case workflow, use the article on choosing the enclosure before PCB layout. This sizing method focuses on the assembled stack and its expansion space.
Calculate the installed envelope
-
Choose the stack orientation and measurement datums. Define enclosure width as X, height as Y and depth as Z. Mark the mounting-plate surface and a repeatable board mounting-hole datum. Decide whether the board faces will sit parallel or perpendicular to that plate. Changing orientation later moves connector access, cable routes and the required enclosure depth.
-
Place every board in its required position. Build a three-dimensional assembly or a dimensioned drawing from the actual mounting interfaces. Include the bottom standoffs, mounting plate, screw heads, nuts and washers. Establish each board's elevation using its specified spacers and connector engagement. Do not estimate stack height by multiplying the board count by one assumed spacing.
-
Add components above and below every board. Include heat sinks, memory modules, storage devices, batteries and other projections. Check the space between adjacent boards as well as the two outer faces. An enclosure can have enough overall depth while two internal components still collide. Keep any electrically required clearance separate from convenient assembly space.
-
Model every connector in its mated condition. Measure from the board datum to the farthest point of the installed plug or backshell. Include latch travel, locking screws and strain relief. A receptacle's projection alone does not describe the connection. Right-angle plugs can save depth while increasing the space required along another axis.
-
Route the cables at their permitted bend radii. Include the straight section behind each plug before the first bend. Use the cable manufacturer's bend requirements, distinguishing installed bends from repeated movement where applicable. Avoid reserving the same space for both a cable bend and a future board. Provide support so cable weight does not load board connectors; the article on service-loop retention without enclosure holes covers retention approaches.
-
Check access and removal paths. Identify how you will release each latch, reach each screw and separate stacked connectors. Show the direction and distance required to remove the top board or withdraw the complete assembly. Some service space can extend through the open door, but only if the opening and surrounding equipment permit that movement. Distinguish this temporary access volume from space that must remain clear during operation.
-
Add a bounded future configuration. Specify the number of additional boards, their permitted stacking positions and their maximum component and connector envelopes. Use an identified candidate board when possible. If future hardware is unknown, define the largest acceptable envelope rather than promising universal interchangeability. Record what changes will trigger a new enclosure fit review.
-
Convert the envelope into usable enclosure dimensions. Find the minimum and maximum occupied coordinates along each axis. Add the required separation from walls, door hardware and other equipment. Compare those requirements with usable internal dimensions, not the enclosure's external width, height and depth. The enclosure sizing guide covers the broader allowances needed around equipment and wiring.
A connector passing through the enclosure wall needs another check. Its panel thickness range, gasket footprint and fastener access must match the proposed wall arrangement. Use the article on mounting an industrial connector on an enclosure for that interface.
Turn expansion space into measurable dimensions
An expansion allowance needs a location, not just a percentage. Adding 20% to total enclosure volume does not guarantee another board will fit above the stack.
The following example uses hypothetical measurements for a particular assembly. These are usable-space requirements, not catalog enclosure dimensions or universal PC/104 clearances.
| Axis | Installed operating envelope | Reserved future envelope | Additional fit allowance, total | Minimum usable span |
|---|---|---|---|---|
| X, width | 5.2 in [132 mm] | 0.4 in [10 mm] beside an edge connector | 0.2 in [5 mm] | 5.8 in [147 mm] |
| Y, height | 4.5 in [114 mm] | None for the defined upgrade | 0.2 in [5 mm] | 4.7 in [119 mm] |
| Z, depth | 3.6 in [91 mm] | 0.8 in [20 mm] above the stack | 0.2 in [5 mm] | 4.6 in [117 mm] |
Here, the installed envelope already includes the mounting hardware, mating connectors and routed cable bends. The reserved depth accommodates one defined future stack increment, including its required component clearances. The width reserve accommodates that upgrade's connector projection.
The additional fit allowance is illustrative. Set your actual allowance from dimensional tolerances, assembly variation and required separation. Use the PCB enclosure tolerance-stack check when nominal dimensions leave little room.
Do not consume the reserved space with terminals, cable supports or door-mounted equipment during final assembly. Show the reserved volume on the drawing and label its intended use.
Mechanical expansion also changes thermal requirements. A future processor or interface board may fit physically but exceed the available heat rejection. If the design transfers heat directly to the enclosure, coordinate that interface with the guidance on conduction-cooled sealed enclosures.
Check the layout before releasing the drawing
Verify fit with the actual mating cable assemblies whenever possible. A full-size mockup can reveal access problems that separate component drawings conceal.
Check the assembly in its operating and service configurations:
- The door closes without pressing on cables, plugs or the stack.
- Door hardware and internal brackets stay outside all required clearances.
- Connector latches and retaining screws remain accessible.
- Cables follow their specified bend limits without pulling on receptacles.
- Every mounting screw can be installed and tightened with the intended tool.
- The complete stack, or each serviceable board, has a workable removal path.
- The future configuration fits without relocating fixed enclosure penetrations.
- Cooling hardware and bonding connections remain accessible after expansion.
Perform physical fit checks with power removed and stored energy controlled. Account for electrostatic-discharge precautions when handling boards.
Check both board and enclosure tolerances before approving a close fit. A nominally clear plug can contact a wall when connector placement and bracket tolerances accumulate.
Avoid changes that compromise enclosure protection
Do not treat a tight mechanical fit as permission to modify sealing surfaces or squeeze cables through an unsuitable opening. Moving a connector after fabrication can leave unused holes and inadequate gasket land.
Common mistakes include:
- Cutting a larger opening to clear a backshell without checking the connector's sealing footprint.
- Routing cables across the door gasket or trapping them behind the latch.
- Drilling mounting holes through the enclosure without an approved sealing arrangement.
- Adding ventilation openings after discovering that the future stack runs hotter.
- Assuming an individually rated connector establishes the completed enclosure's protection.
For our custom enclosures, ratings are manufacturer ratings for the specified design; the enclosures are not UL listed. Changes to openings, hardware or sealing arrangements require review against that design.
Keep mounting loads off board connectors. Support the stack through its specified mechanical mounting points, and secure external cables independently where needed.
Put the complete envelope on the enclosure drawing
Send the board assembly and enclosure requirements together. A board outline alone is not enough to define a custom box.
Specify the required usable width, height and depth, plus the intended stack orientation. Include mounting-hole coordinates, standoff heights, connector cutouts and cable-entry locations. Identify the door opening direction and the service removal path.
Mark the expansion volume separately from the current equipment. State the maximum future stack height and permitted connector overhang in each direction. Include drawing revisions and any dimensions awaiting confirmation before approval.
We build custom enclosures with customer-defined material, dimensions and cutouts, from one piece. Use the enclosure builder to configure the enclosure, then carry the detailed stack envelope into the drawing review. Approve the drawing only after checking usable internal space against the complete present and future assemblies.
Enclosures for this job
Catalog sizes that suit the job this article answers, picked from its subject; open one for its full specifications.
| Enclosure | Material | Outside H x W x D / display | Rating |
|---|---|---|---|
| 12 × 10 × 6 in | 304 stainless | 12 x 10 x 6 in | Rated NEMA 4X / IP66 by the manufacturer; not UL listed |
| 20 × 16 × 8 in | 304 stainless | 20 x 16 x 8 in | Rated NEMA 4X / IP66 by the manufacturer; not UL listed |
| 24 × 20 × 8 in | 304 stainless | 24 x 20 x 8 in | Rated NEMA 4X / IP66 by the manufacturer; not UL listed |
Questions
Do PC/104 board dimensions define the enclosure size?
No. The board outline does not include the complete installed assembly. Mating plugs, backshells, cable bends, component heights, mounting hardware and cooling parts can extend beyond it. Use the applicable form-factor specification together with each board's mechanical drawing and the actual cable assembly dimensions.
How much room should I reserve for future PC/104 boards?
Reserve space for a defined future configuration rather than a percentage of enclosure volume. Specify additional stack height, component clearances, connector projections and cable routes. If no future board is selected, establish dimensional limits and require a new fit review for hardware exceeding them.
Will boards with the same mounting pattern always fit?
Not necessarily. A shared mounting pattern does not guarantee identical peripheral connectors, component heights, cooling arrangements or service access. Check the applicable stacking interface and the complete mechanical envelope before treating a replacement board as interchangeable within the existing enclosure.
Should the drawing specify external size or usable internal space?
Specify the minimum usable internal dimensions established by the assembled stack and its clearances. External enclosure dimensions also include walls, door construction and other features. Confirm the mounting plate position, door hardware and opening dimensions before approving the enclosure drawing.