Panel mount header cutout: reading C and D dimensions

Cut 0.284 in wide by 0.429 in high (7.21 x 10.90 mm) at ±0.004 in [±0.10 mm] for the 4-position panel-mount header; C and D are filled from the drawing's cutout table by position count. Match the printed panel-thickness window to your measured door before the hole is cut.

NEMA4 Enclosure engineering team · Published November 23, 2026 · 6 min read

Short answer: the datasheet does print your cutout, just not on the view itself. C and D are two blanks on the panel-cutout drawing, and a small table fills them by position count; for the 4-position Micro-Fit 3.0 panel-mount header, part number 0430200400, the row reads 0.284 in wide by 0.429 in high, which is 7.21 by 10.90 mm, at ±0.004 in [±0.10 mm]. Before anyone touches a stainless door, match the panel-thickness note on the same sheet to a caliper reading, then send the full-scale view with the order. The steps below run from part number to a checked, snapped-in header.

Where do C and D come from on the header drawing?

C and D are the two blanks on the cutout view, filled from a table keyed by position count: the 4-position row reads 0.284 in [7.21 mm] wide by 0.429 in [10.90 mm] high. The header is a 3.00 mm pitch, dual-row snap-in part, and one sheet serves every size in the family, which is why the view carries blanks at all. The table makes the sheet specific: each row is a position count, and it gives both numbers. Write your row onto the cutout sketch first, and the rest of the view — ear pockets, key, thickness note — already fits the family.

Header Positions C, width D, height Tolerance
0430200400 4 0.284 in [7.21 mm] 0.429 in [10.90 mm] ±0.004 in [±0.10 mm]
Other counts in the family your count your row your row same block

For glands, D-sub families and display windows, the cutouts, glands and HMI windows guide carries the general practice.

How do you find your row in the cutout table?

Count the circuits from the part number: on 0430200400 the 04 near the end means four positions, and that is the row you fill in. Both blanks are keyed to the count, so read both from your row. Along the row, every added column widens the opening by one 3.00 mm pitch, and a hole cut from the wrong row leaves the ears clicking on nothing. The sheet prints inch and millimetre columns for the same row; check them against each other once at 25.4 mm per inch, then cut from whichever your shop works in.

What else does the cutout view carry besides C and D?

Three things the two numbers miss: the tolerance block, the panel-thickness note, and the snap-in ears and alignment key drawn to scale. The tolerance block applies to every blank dimension unless one carries its own, and it is what turns C and D into the measuring window you check against later. The ears deflect and lock behind the panel, and the key sets the body's rotation, so a plain rectangle without the ear pockets lets a header sit loose or go in rotated. That is why a quote gets the full-scale view from the connector sheet, not two typed numbers.

Will the snap-in ears hold in your stainless door?

They hold only inside the panel-thickness window printed as a note on the cutout sheet, and a stainless door often runs thicker than the sheet these ears were designed to bite, so measure with a caliper first. The window sits outside the C and D table and differs between mounting styles, so read it off your own sheet. The common stainless gauges:

Stainless sheet, Brown and Sharpe gauge Thickness
18 ga 0.050 in [1.27 mm]
16 ga 0.0625 in [1.59 mm]
14 ga 0.0781 in [1.98 mm]

Three cases decide it. Inside the window: cut the door directly, on the flat face and inside the gasket land. Above the maximum: spot-face a shallow recess on the inside face so the ears see a thinner section, kept off the gasket land so the door seal never touches it. Below the minimum: carry the header on a thin internal plate screwed to the door, because the ears have too little to bite.

How do you cut the hole step by step?

Six steps take you from the table row to a snapped-in header; the caliper gates both ends, door thickness at the start and the 7.21 by 10.90 mm window at the finish.

  1. Write your row onto the cutout sketch: C 7.21 mm, D 10.90 mm, for the 4-position part.
  2. Caliper the door or plate and compare with the sheet's thickness note; plan the spot-face or the carrier plate before cutting if the reading lands outside.
  3. Dimension the position from two real edges of the door, X and Y, and keep the opening on the flat face, clear of the gasket land and the door return.
  4. Picture both faces of the panel: the plug body and its latch stand proud in front, the tails and the wire bend live behind, so the spot needs room on both sides.
  5. Cut from the full-scale view — a punch press or laser for repeat work, or pilots, saw and file to a 1:1 print for a one-off. How to cut a hole in a stainless steel enclosure walks through the shop methods.
  1. Deburr both faces, since a rolled edge on the inside holds the ears off their seat. For repeat orders, send the cutouts with the box; bulk cutouts: factory or shop machining compares the two routes.

How do you check the cutout when it is done?

Measure C and D with calipers at three points each and hold every reading inside the window: 7.11 to 7.31 mm wide and 10.80 to 11.00 mm high. Worked example, 4-position header on a 16 ga door at 0.0625 in [1.59 mm]. The sheet gives 0.284 in by 0.429 in at ±0.004 in. Convert at 25.4 mm per inch: 0.284 × 25.4 = 7.21 mm, and 0.429 × 25.4 = 10.90 mm, matching the sheet's millimetre column. Applying the tolerance opens these to the ranges above. A punched hole measuring 7.24 by 10.95 mm sits inside both, so it passes. Push the header home: both ears should click behind the panel, and a seated part should need a flat blade behind one ear to release. If it pulls out by hand, the hole is oversize — measure again before blaming the connector.

What does a header through the door do to the enclosure rating?

It opens the door: the connector system is unsealed, so a header in a washdown door is a live water path, and the port belongs behind the closed door or under a gasketed cover. Our stainless boxes are rated NEMA 4X / IP66 by the manufacturer; not UL listed, and that rating belongs to the closed enclosure, sealing at its gasket, glands and windows as fitted. A snapped-in header with the plug outside sits outside that sealing story. In a dry interior cabinet, cut the door and plug in freely. On a washdown line, mount the header on an internal plate you reach with the door open, or keep it on the door under a latched, gasketed cover sized around the plug. What NEMA rating a panel keeps after you cut it and mount devices sorts the rest of the mounted-device cases.

What do you send when the cutout is ordered with the enclosure?

Send the connector sheet's cutout view at full scale, the face and the X-Y position from two datum edges, C and D with their ±0.004 in tolerance, and the door material and thickness. The cutout designer places the opening on any face, checks spacing and sends the layout with the quote request. For a fully custom body, the custom stainless enclosures page starts from real 304 and 316L sizes and adds a drawing checklist. Check the returned drawing before cutting — enclosure drawing checks before fabrication lists what to catch — and custom work is delivered in 10 business days, counted from your approval of the drawing.

Catalog dimensions to compare

Compare these catalog dimensions with your component layout. Open each enclosure for its rating, material and usable space, then check those specifications against your application.

EnclosureMaterialOutside H x W x D / displayRating
12 × 10 × 6 in304 stainless12 x 10 x 6 inRated NEMA 4X / IP66 by the manufacturer; not UL listed
16 × 14 × 8 in304 stainless16 x 14 x 8 inRated NEMA 4X / IP66 by the manufacturer; not UL listed
20 × 16 × 8 in304 stainless20 x 16 x 8 inRated NEMA 4X / IP66 by the manufacturer; not UL listed

Questions

What is the cutout for other position counts in the same header family?

The same table carries one row per position count, and the sheet's tolerance block applies to every row unless a dimension carries its own. Read both blanks from your row: every count above the 4-position part is wider along the row, roughly one 3.00 mm pitch per added column, so a hole cut from the wrong row leaves the ears clicking on nothing.

Can you cut the rectangular hole with hand tools?

For a one-off, yes. Print the cutout view at 1:1, fix it to the door, drill a pilot in each corner and file to the printed lines. In practice, careful hand work lands within about ±0.2 mm, twice the ±0.10 mm window, so measure with calipers and stop at the low limit. Beyond a few holes, a punch press, laser or waterjet holds the window without filing.

Does the header seal the hole in a washdown enclosure?

No. The connector system is unsealed, so a header through the door leaves an opening that spray follows, and the NEMA 4X / IP66 rating, a manufacturer rating on our stainless boxes, belongs to the closed enclosure. Inside the door the header stays inside that sealing story; outside it, only a latched cover with its own gasket, sized around the plug, keeps the water out.

What if the stainless door is thicker than the printed window?

Spot-face a shallow recess on the inside face so the ears see a thinner section. A 14 ga door at 0.078 in [1.98 mm] machines down a few tenths of a millimetre where the ears sit. Keep the recess on the flat face and off the gasket land, so the door seal never touches it. A thin carrier plate screwed inside the box does the same job without touching the door.

Checklist before you order

Specify it once, built to your drawing

  • Environment and NEMA type: Type 1, Type 3R, Type 4, Type 4X, Type 6P, Type 12, Type 13 (manufacturer ratings, not UL listed)
  • Material: 304 stainless steel, 316L stainless steel, Powder-coated carbon steel, Aluminum, Polycarbonate, Fiberglass (FRP)
  • Size: inside or outside height, width and depth, with the depth your deepest component needs
  • Cutouts, glands and windows, dimensioned from one datum on each face
  • Mounting and access: wall, pole or stand, hinge side, mounting panel
  • Quantity: from one piece

Delivered in 10 business days, anywhere in the world. Counted from your order; for custom work, from your approval of the drawing.

Build it from 12 × 10 × 6 inRequest a custom quote

NEMA 4X enclosures: sizes for this job

Keep reading

More on layout and installation

All articles

Buying guides

The guides behind this answer

All guides