Kinematic closed chain jog disabled after the second loop

Open Joint Jog disables the moment the second closed chain is added for two construction reasons: the closing joint's arrow points forward instead of backward, or the second chain introduced a second fixed link. Point the last arrow backward, reuse the one fixed link the model already has, and build the prismatic output manually; a 6-link, 7-joint two-loop model then keeps exactly 1 degree of freedom.

NEMA4 Enclosure engineering team · Published November 10, 2026 · 7 min read

Short answer: the mechanism is not the problem; the closure is. In manual construction the last arrow of each closed chain must point backward, so J3 closes loop 1 correctly and J7, the closing joint of loop 2, is the one to fix. The kinematic editor also allows exactly 1 fixed link per model, so chain 2 has to reuse the ground chain 1 already uses. Fix the closing arrow first, then count the fixed links. The Three Point crank in Create Crank defines a rotating output, so a prismatic output joint gets built by hand. The arithmetic below uses a 6-link, 7-joint two-loop model built around a 200 mm [7.9 in] stroke slider: one ground leaves 1 degree of freedom, a second ground leaves -2 and a locked model.

What the symptoms tell you

Read the symptoms in order; each one narrows the fault before you touch geometry.

  • Jog works with loop 1 closed, then Open Joint Jog greys out the moment loop 2 closes. The fault sits in loop 2's closure: a forward closing arrow or an extra fixed link. This is the most common signature, and the one to chase first.
  • Jog is already disabled while only loop 1 exists. The first chain carries the fault. Check its arrow directions and joint types before any second loop goes in.
  • Create Crank builds a chain, but the output turns when you need a slide. The Three Point template defines a revolute output. Rebuild the output chain manually with a prismatic joint.
  • The model assembles but never jogs after closure. Count the fixed links in the finished model. A count of 2 locks a two-loop model; the arithmetic section shows why.
  • Jog dies only at both ends of the stroke. That is dead center, at 0° and 180° crank angle on a centric crank-slider. It is a property of the linkage, not a fault.

Pin the failure to one operation before changing anything. Retest Open Joint Jog immediately before the second closure and immediately after. The same before-and-after habit that traces a controller that reboots only when the lid closes pins this fault to a single command.

Check the closing arrow first

The last arrow of a closed chain must point backward, toward the link that closes the loop. The arrow is the direction the editor travels while it builds the chain; it is not the mechanism's intended travel direction. In the two-loop example, J3 closes loop 1 pointing backward and reads correct; J7 closes loop 2 pointing forward and breaks the model.

Walk loop 2 and compare its closing joint against J3, the one that works. Redefine J7 so its arrow runs from the last new link back to the link that closes the loop. Keep direction and joint type as separate checks: flipping the arrow changes the traversal only, so a revolute stays revolute and a prismatic stays prismatic. Do not reverse arrows deeper in the chain; the construction rule targets the closing joint.

Retest Open Joint Jog straight after the change. The forward closing arrow is the most likely cause, so settle it before the fixed-link question opens.

The editor allows exactly 1 fixed link per kinematic model. Two loops share that one ground even when their moving parts differ; a second chain never earns its own.

With Create Crank, build loop 1 and jog it. Reopen the wizard for chain 2, and on the page that asks for the fixed link, select the link already grounded in loop 1. The second ground slips in here, because the second wizard pass looks like a fresh start.

Check a finished model by counting the grounded links. The count must read 1. If it reads 2, rebuild chain 2 in a second wizard pass and pick the existing fixed link when the page asks. Do not patch the extra ground in place; rebuild the pass, because the closure geometry is easier to re-create than to repair.

Two loops on one ground: the arithmetic

Name the model before counting. The example linkage is a press-style drive with a 200 mm [7.9 in] stroke. Loop 1 is the frame, a crank of 50 mm [2.0 in] radius, a connecting rod of 150 mm [5.9 in] and a slider; loop 2 adds a second crank and rod, pinned to the same slider. All links are rigid and the motion stays planar, the standard assumption behind the count.

Loop Links Joints Closing joint
Loop 1: crank-slider 4 J1, J2, J3 and prismatic J4 J3
Loop 2: second crank 4, two shared with loop 1 J5, J6, J7 plus shared J4 J7
Model total 6 7 -

The Kutzbach criterion for a planar mechanism with lower pairs gives the degrees of freedom: DOF = 3(n - 1) - 2j, with n links and j single-axis joints.

One ground: DOF = 3(6 - 1) - 2 x 7 = 15 - 14 = 1. One input drives the whole model, and jog moves it.

Two grounds, with crank B pinned to its own grounded link: DOF = 3(6 - 2) - 2 x 7 = 12 - 14 = -2. The loop carries 2 redundant constraints and becomes a structure. The editor answers with a disabled jog command.

A single crank-slider confirms the method: 4 links, 4 joints, DOF = 3(4 - 1) - 2 x 4 = 9 - 8 = 1.

When the template output turns by mistake

The Three Point crank defines its output as a rotation. Your output must slide along the 200 mm [7.9 in] stroke axis, so a finished Three Point build is the wrong mechanism even when it jogs happily. Build the output chain by hand: define the output joint as prismatic, lay its axis on the slide direction, point its closing arrow backward, and reuse the single fixed link.

Check the axis, not just the type. A prismatic joint aimed even 5° off the slide direction still binds the slider over the full stroke, even with a clean name on it. If you prefer the wizard, run it in two passes and reuse the ground; manual construction simply gives you direct control over the joint arrangement where the template cannot.

Positions that lock by design

Some positions resist motion by geometry. On a centric crank-slider, crank and rod line up twice per revolution, at 0° and 180° crank angle; the slider sits at end of stroke and instantaneous motion through the point goes stiff. That is dead center, and it repeats at the same crank angle every cycle.

A construction fault behaves differently: it kills jog at every position, not just at the two line-up points. Confirm the closing arrow, the fixed-link count and the joint types first, then jog a few degrees either side of the stiff spot. Free motion at 30° and a stick at 0° is dead center, not a fault.

The fix, in order

  1. Baseline. With only loop 1 built, confirm Open Joint Jog is enabled and the model moves as intended.
  2. Arrow. Redefine loop 2's closing joint, J7 in the example, so its arrow points backward, matching J3.
  3. Retest. Jog again. Enabled means done; still disabled means continue.
  4. Ground count. Count the fixed links in the finished model and rebuild chain 2 through a second Create Crank pass, selecting the existing fixed link, until the count reads 1.
  5. Output joint. Confirm the output is prismatic and its axis lies on the slide direction.
  6. Full stroke. Jog the whole 200 mm [7.9 in] travel; expect stiff spots at 0° and 180° crank angle and free motion between them.

If the model has collected flipped arrows and extra grounds from several attempts, rebuild it from a clean skeleton. Five minutes of clean construction beats an hour of archaeology on a patched chain.

When the model is right and the machine still refuses

An editor refuses jog over model validity. A machine refuses jog over interlocks, and from the seat the two feel identical: the command greys out and nothing moves. A guard door that stands open blocks jog by design; the CNC machine door interlock article covers jogging with doors open and stopping a running job.

Wiring has its own version of the second-loop failure: a working cabinet that misbehaves once a second signal path closes a loop. The control signal ground loop checks cover that one.

Once the model validates, the machine tool's own chain follows the same conventions of joint direction and a single ground; configuring a mill-turn kinematic chain in the MillPlus G7 control shows those conventions on a real machine tool.

And when the finished linkage needs a housing, send the same CAD geometry to the custom enclosures section; the walkthrough from a board 3D model to a custom enclosure in 10 business days shows what to send. We build to your drawing from one piece, delivered in 10 business days, counted from your approval of the drawing.

Catalog dimensions to compare

Compare these catalog dimensions with your component layout. Open each enclosure for its rating, material and usable space, then check those specifications against your application.

EnclosureMaterialOutside H x W x D / displayRating
12 × 10 × 6 in304 stainless12 x 10 x 6 inRated NEMA 4X / IP66 by the manufacturer; not UL listed
20 × 16 × 8 in304 stainless20 x 16 x 8 inRated NEMA 4X / IP66 by the manufacturer; not UL listed
24 × 20 × 8 in304 stainless24 x 20 x 8 inRated NEMA 4X / IP66 by the manufacturer; not UL listed

Questions

How many degrees of freedom should a finished two-chain model have?

One. The Kutzbach count for a planar two-loop model with 8 links and 10 joints reads 3(8 - 1) - 2 x 10 = 21 - 20 = 1, so a single input drives every link. Give the model a second fixed link and the same count reads 3(8 - 2) - 2 x 10 = -2, a locked structure. Jog needs that 1.

Why does jog stay enabled while both chains are still open?

An open chain is a tree. Six links joined by 5 joints give 3(6 - 1) - 2 x 5 = 15 - 10 = 5 degrees of freedom, and any positive count moves. Closure adds constraints: 7 joints drop the model to 1 degree of freedom, and a wrong closure drops it below zero, which the editor reports as a disabled Open Joint Jog.

Does pointing the closing arrow backward change the joint type?

No. The arrow sets the direction the editor travels along the chain; the joint type is a separate definition. A prismatic joint still allows motion along 1 axis and a revolute still allows rotation about 1 axis after the flip. Fix J7's direction, retest jog, and redefine a joint type only if the output must slide.

What blocks jog on the machine after the model validates?

Interlocks, not the kinematic. A guard-door switch in a 24 V DC safety circuit refuses jog while the door stands open, the same refusal pattern the editor uses on an invalid chain. Close the guard, clear nobody from the envelope, and jog; leave the interlock in the circuit.

Checklist before you order

Specify it once, built to your drawing

  • Environment and NEMA type: Type 1, Type 3R, Type 4, Type 4X, Type 6P, Type 12, Type 13 (manufacturer ratings, not UL listed)
  • Material: 304 stainless steel, 316L stainless steel, Powder-coated carbon steel, Aluminum, Polycarbonate, Fiberglass (FRP)
  • Size: inside or outside height, width and depth, with the depth your deepest component needs
  • Cutouts, glands and windows, dimensioned from one datum on each face
  • Mounting and access: wall, pole or stand, hinge side, mounting panel
  • Quantity: from one piece

Delivered in 10 business days, anywhere in the world. Counted from your order; for custom work, from your approval of the drawing.

Build it from 12 × 10 × 6 inRequest a custom quote

NEMA 4X enclosures: sizes for this job

Keep reading

More on layout and installation

All articles

Buying guides

The guides behind this answer

All guides