How to design an enclosure in a browser

Design an enclosure in a browser by defining the envelope, component clearances, mounting and cutouts before requesting a quote. Use the visual model to communicate the layout, then verify the returned drawing as the manufacturing specification before approval.

NEMA4 Enclosure engineering team · Published October 30, 2026 · 6 min read

You can design an enclosure in a browser without installing desktop software. Start with the enclosure envelope, place the component requirements, then define mounting and cutouts. Use the enclosure builder for the overall configuration and the cutout designer for openings. The browser model communicates your design intent. The drawing returned for approval must resolve the dimensions, clearances and construction details before manufacturing starts.

What you need before opening the builder

Gather the information that controls the layout. A component photograph or a nominal screen size cannot replace a dimensioned installation drawing.

Have these items available:

  • Component drawings showing bodies, mounting points, connectors and required installation clearances.
  • Cable outside diameters, connector dimensions and minimum bend radii from the cable manufacturers.
  • The installation environment, including water exposure, dust, chemicals, ambient temperature and sunlight.
  • Equipment losses in watts, expected operating duty and any cooling requirements.
  • Mounting orientation, available wall space, door-opening space and cable approach directions.
  • Required material, enclosure rating and project approval requirements.

Keep a browser-accessible worksheet alongside the model. Record assumptions and unresolved dimensions there rather than relying on the visual layout alone.

The enclosure sizing guide covers the underlying sizing method. The workflow below turns those requirements into a browser configuration and an approval package.

Follow the layout from envelope to drawing

  1. Start with an envelope, not a finished box.

    Open the builder and choose a ready-made starting configuration or begin from scratch. Enter width, height and depth, and record the units. State whether your requested dimensions describe the outside enclosure or the usable internal space. Do not assume those dimensions are interchangeable.

    For custom enclosures, you define the material, width, height, depth and every cutout. Treat the initial envelope as provisional until the component layout and cable routing fit. Increasing depth later can change mounting loads, door access and available installation space.

  2. Set the environmental and construction requirements.

    Select the material, required NEMA type, door arrangement and mounting approach. Record the exposure behind each choice. Outdoor rain, routine hose-down and chloride exposure are different design conditions.

    A hose-down application may call for NEMA 4X, with material compatibility checked separately. Ratings are manufacturer ratings for the specified design; our enclosures are not UL listed. If the project requires a listing, resolve that requirement before proceeding. The builder's selectable rating does not establish suitability for every chemical or installation condition.

  3. Build the component layout from usable space.

    Work from mounting surfaces and component envelopes, not just the enclosure outline. Reserve space for backplate edges, door hardware, terminals, wiring duct and service access. Use the component manufacturers' required clearances rather than a universal spacing rule.

    If detailed component placement is outside the browser tool's available features, keep a separate dimensioned layout. Reference that layout in the quote request. Our article on component layout inside a sealed enclosure explains why physical fit and heat-producing component placement need separate attention.

  4. Check depth with connectors and wiring installed.

    Include the backplate offset, device projection, installed connectors, cable bends and door-mounted equipment. Check the closed-door condition and the space needed to disconnect or replace components.

    For example, suppose an installed assembly projects 6 in [152 mm] from its mounting surface. A hypothetical additional clearance of 1.5 in [38 mm] requires 7.5 in [191 mm] from that surface. That is not a universal clearance rule, and an enclosure 8 in [203 mm] deep externally may still be too shallow. Confirm the actual mounting-surface-to-door dimension and the component's documented requirements.

  5. Lay out each cable entry and operator opening.

    Use the cutout designer to place holes, cable glands, pushbuttons and display openings on the required faces. It checks spacing, exports the layout and sends it with a quote request. Review each opening against the actual device drawing.

    Specify the face, viewing direction, datum, coordinates, shape, dimensions and any orientation feature. For example, a hole center can be dimensioned from the left and bottom edges of a face viewed from outside. Do not switch to an inside view without clearly identifying the change. A gland's nominal thread designation is not necessarily its required clearance-hole diameter.

  6. Check both sides of every opening.

    The visible hole is only part of the installation envelope. Allow room outside for the gland body, connector or operator bezel. Allow room inside for locknuts, terminals, cable bends and installation tools. Keep sealing surfaces clear of bends, welds and adjacent hardware.

    The article on installing a cable gland without losing the rating covers fitting selection and installation details. A browser spacing check cannot replace those requirements. Also check that cable supports prevent sustained loads from reaching the entry seals.

  7. Resolve mounting, access and heat before requesting the quote.

    State the installation orientation, support arrangement and expected loaded weight. Check door swing, access to fasteners and room to service internal devices. Prefer mounting arrangements that avoid unnecessary penetrations through the protected enclosure boundary.

    If through-wall mounting is unavoidable, define the sealing method rather than leaving it to installation. The article on mounting screws through an outdoor enclosure without leaks addresses that detail. Record heat losses and site temperatures separately. Selecting a climate option in the builder does not replace a thermal calculation.

  8. Send a controlled package and review the returned drawing.

    Send the configuration and exported cutout layout with the component drawings, environmental requirements and unresolved questions. Give the package a revision identifier. Make clear which dimensions are mandatory and which may change during manufacturing review.

    Review the returned drawing against that same package. Confirm material, dimensions, construction, mounting, cutout locations and the specified rating before approval. The article on enclosure drawing callouts covers the specification details that belong on the drawing. Custom enclosures are delivered in 10 business days, counted from your approval of the drawing.

Know what the browser model does not prove

A visual model helps communicate shape, arrangement and access. It does not automatically establish electrical clearances, thermal performance, structural capacity or environmental protection.

Separate the information into three groups:

Information What you should do with it
Configured dimensions and options Compare them with the quote and returned drawing
Component and cable requirements Verify them against manufacturer installation documents
Thermal, electrical and mounting requirements Resolve them through the applicable engineering review
Unconfirmed construction details Obtain confirmation before approving manufacture

Do not treat an opening that fits onscreen as evidence that the installed device preserves the enclosure rating. The complete installation includes the device, gasket, fasteners, wall thickness and assembly method.

Our explanation of enclosure ratings after mounting devices covers that distinction. Keep the browser configuration and supporting calculations together so later changes remain traceable.

Checks before approving the drawing

Review the drawing in a fixed order. Start with the overall enclosure, then move through mounting, components, openings and sealing details.

  • Dimensions: Confirm units, width-height-depth order, external dimensions and the usable internal dimensions that control fit.
  • Orientation: Confirm the hinge side, opening direction, mounting face and outside viewing direction for every cutout layout.
  • Components: Check the installed envelope, terminal access, removal paths and required manufacturer clearances.
  • Cable entries: Match each opening to the selected fitting, cable range, sealing hardware and installation requirements.
  • Mounting: Check support locations, fastener access, loaded weight and any penetrations through the enclosure wall.
  • Door condition: Check interference with door hardware, wiring loops and door-mounted devices when fully closed and opened.
  • Environment: Confirm the material, specified rating, heat-control approach and relevant chemical exposure.
  • Revision control: Confirm that the quote, layout export and approval drawing describe the same revision.

Resolve discrepancies in the returned drawing before approval. A note in an earlier message should not contradict the approved manufacturing dimensions.

If equipment or cable selections change afterward, repeat the affected checks. A smaller device can still need a larger connector clearance or a different cutout.

Mistakes that cost the rating

Choosing openings before choosing fittings. Select the gland, connector or operator first. Then use its installation drawing to define the opening and sealing requirements.

Using sealant to rescue an incorrect cutout. Sealant is not a substitute for the specified gasket land, wall thickness or fastening arrangement. Resolve oversized or misplaced openings through an agreed repair or revised part.

Adding unreviewed ventilation or drainage holes. An open hole changes the enclosure boundary. Specify an appropriate environmental-control arrangement rather than assuming the original rating survives.

Letting mounting hardware distort sealing surfaces. Poor support or excessive fastener loads can affect door alignment and gasket compression. Review support and sealing together.

Approving only the appearance. A clean model can hide missing dimensions, mirrored openings and inaccessible locknuts. Approve a dimensioned, manufacturable specification, not just a convincing view.

Making field changes without updating the design. Additional holes and substituted devices require another rating and clearance review. Keep the final configuration, drawing and installed assembly consistent.

Enclosures for this job

Catalog sizes that suit the job this article answers, picked from its subject; open one for its full specifications.

EnclosureMaterialOutside H x W x D / displayRating
12 × 10 × 6 in304 stainless12 x 10 x 6 inRated NEMA 4X / IP66 by the manufacturer; not UL listed
16 × 14 × 8 in304 stainless16 x 14 x 8 inRated NEMA 4X / IP66 by the manufacturer; not UL listed
20 × 16 × 8 in304 stainless20 x 16 x 8 inRated NEMA 4X / IP66 by the manufacturer; not UL listed

Questions

Can I design an enclosure without installing software?

Yes. Use the browser-based enclosure builder to define the overall configuration and the cutout designer to arrange openings. Keep component drawings and installation requirements alongside the configuration. Review the returned manufacturing drawing before approving the enclosure.

Is the browser model enough to manufacture the enclosure?

No. A visual model communicates the proposed arrangement, but manufacturing also needs confirmed dimensions, material, construction details, mounting and cutout information. The returned drawing must resolve those requirements and any conflicts before you approve production.

What information should I provide for each cutout?

Identify the enclosure face, outside viewing direction, reference edges, coordinates, opening dimensions and orientation features. Include the selected device's installation drawing. Check the space needed for gaskets, locknuts, cable bends and tools on both sides of the opening.

Does the configured enclosure depth guarantee that my components fit?

No. Overall depth does not equal usable depth from a component mounting surface to the closed door. Include backplate offsets, device projection, installed connectors, cable bends, door hardware and the clearances required by each component manufacturer.

Checklist before you order

Specify it once, built to your drawing

  • Environment and NEMA type: Type 1, Type 3R, Type 4, Type 4X, Type 6P, Type 12, Type 13 (manufacturer ratings, not UL listed)
  • Material: 304 stainless steel, 316L stainless steel, Powder-coated carbon steel, Aluminum, Polycarbonate, Fiberglass (FRP)
  • Size: inside or outside height, width and depth, with the depth your deepest component needs
  • Cutouts, glands and windows, dimensioned from one datum on each face
  • Mounting and access: wall, pole or stand, hinge side, mounting panel
  • Quantity: from one piece