Those plastic posts are heat staked standoffs: a molded boss whose stud passes through the board's corner hole and is melted into a cap, which is why they look like single-use rivets. Short answer: cut the melted cap off level with the top of the board and lift the board free. Then drill a pilot down the stub's center and refit it with an M3 self-tapping screw that stops 2 mm short of your housing wall. Done that way the joint carries the board as well as the rivet did, and it comes apart again with a screwdriver. The whole job takes about 15 minutes at a bench, and you need nothing beyond a soldering iron, a drill and one screw.
What are the plastic posts holding the PCB to its housing?
They are heat staked standoffs, sometimes called staked bosses: a plastic stud from a molded boss passes through a corner hole in the PCB, and an ultrasonic or thermal staking head melts the top 1.5 to 2 mm of the stud into a flat cap that clamps the board.
Makers stake instead of screwing because it is fast, needs no fastener stock and cannot shake loose. On appliance and consumer boards you usually find studs of 2.5 to 4 mm in diameter, sitting in board holes about 0.5 mm larger, so a 3 mm stud runs in a 3.2 mm hole. The cap is the weak point for service: melting it spends the stud's spare length, and there is no thread underneath, only solid plastic. That is why rework is a two-part job — free the board, then rebuild the fixing.
Not sure which family your fixing belongs to? The walkthrough on identifying and sizing PCB boss screws separates heat stakes from threaded standoffs, snap bosses and press pins. Try a gentle pull before you reach for the iron: a press pin pops out under finger pressure, and some posts that look staked are exactly that.
Can you remove a heat staked standoff without wrecking the board?
Yes — cut the cap and the board lifts off: a clean tip at 300 °C [570 °F] parts a 3 mm-wide cap in 2 to 3 seconds, and FR-4 survives soldering at 260 °C, so a quick cut never reaches the copper or the solder joints.
Three methods work, in this order of preference. A temperature-controlled iron with a flat or chisel tip is the standard way, because you hold the tip at 300 °C and nothing hotter wanders across the board. A heat gun softens the cap for a pry, but air hot enough to melt plastic also softens the neighboring bosses and can warp a thin housing. Keep the gun as the fallback. Side cutters are fastest — nip the cap once, just above the laminate — yet the snap can crack the stud down its length and leave you less plastic to drill.
The housing plastic sets your margin. ABS softens from about 105 °C [221 °F] and polycarbonate from about 147 °C [297 °F], their glass-transition points. That is why a controlled 300 °C tip on the cap beats a gun running at 400 °C nearby. Cut level with the board's top face, never 1 mm below it; every millimeter cut below the surface is a millimeter of engagement you cannot recover at refit time.
What do you need for the job?
You need four things: a soldering iron with a flat or chisel tip, a pin vise or hand drill with the pilot bit, a strip of tape for a depth stop, and an M3 self-tapping screw about 8 mm long whose head spans the board's 3.2 mm hole.
- Iron: temperature-controlled, set to 300 °C [570 °F]. A fixed 30 W iron idles its tip above 350 °C and burns ABS into brown sludge before the cut is through.
- Bit: the pilot size in the next sections, 2.5 mm for plain ABS and polycarbonate, 2.4 mm in glass-filled or brittle plastic. Use a sharp bit; a dull one pushes rather than cuts.
- Screw: M3 × 8 self-tapping screw with a Ø6 mm pan head. The head bears 1.4 mm on each side of the 3.2 mm hole — (6 − 3.2) / 2 = 1.4 mm — enough to clamp without overhanging nearby parts.
- Depth stop: one wrap of tape at 7 mm on the bit. This single piece of setup protects the housing wall.
- Extras: side cutters for the cap, isopropyl alcohol and a brush for chips, and a flat washer if a worn board hole has gone oversize.
How do you cut the staked head and free the board?
Work from the cap down to the board's top surface in two passes: a first pass that takes half the cap's height and a finishing pass that leaves it flush, because one heavy pass drags hot plastic across the board and piles a 1 mm burr over the hole.
- Unplug the unit and confirm the board is dead; mains capacitors hold charge for several minutes after the plug comes out.
- Set the iron to 300 °C [570 °F] and let it soak for 3 to 5 minutes, then wipe the tip flat and clean.
- Rest the flat tip on the cap for about 2 seconds and shave from the cap's edge toward the stud center in one pass, stopping level with the board's top face. Two light passes beat one heavy pass.
- Lift the board off the stub with a spudger under a bare corner. If the stub pulls out with the board, press it back into the boss so you keep the full drilling depth.
- Touch the stub top once more with the flat tip to level it. A domed stub walks a drill bit about 0.5 mm off center, and off center is how pilots graze the boss wall.
How do you refit the board on the same boss?
Drill first, fit the board second: a pilot 7 mm deep down the stub's center gives an M3 self-tapper about 6 mm of engaged thread, twice the screw's 3 mm diameter, which is the engagement a loaded board needs.
- Wrap tape around the bit so 7 mm stands proud, or 1 mm less than your boss height if the boss is shorter, and drill straight down the stub's center at low speed.
- Back the bit out every 2 mm to clear the flutes. Plastic should leave as powder; strings mean the plastic is melting and the hole is going oversize.
- Blow out the chips, set the board over the boss and start the screw square. Two turns by hand confirm the thread is finding the pilot.
- Drive slowly until snug, then a quarter turn more. With a torque driver, stop near 0.5 N·m for M3 in ABS; around 1 N·m strips a fresh pilot. These are typical figures, and glass-filled bosses take slightly more.
- Confirm the board sits flat on the boss with no rocking. Rocking means chips under the board or a stub left proud, and a flat seat is what keeps the joint tight.
When the board returns over four bosses at once, check the spacing the way you would measure enclosure mounting boss spacing before drilling all four; forcing a board over a 0.5 mm misalignment bends the board and starts the screws crooked.
How deep should the screw go into a plastic boss?
Aim for 2 to 2.5 times the screw's diameter of engaged thread — 6 to 7.5 mm for M3 — and leave at least 1 mm of un-drilled boss below the pilot so the tip never reaches the housing wall behind it.
Thread-forming screws in ABS and polycarbonate take a pilot near 80 to 85% of the major diameter, which is the 2.4 to 2.5 mm range for M3; glass-filled plastic sits at the low end.
Worked example — a corner boss on a polycarbonate housing with a 2 mm wall. The boss measures Ø8 mm across and stands 9 mm tall, so 9 mm of usable height remains once the cap is off level.
- Tape the bit at 7 mm and drill the pilot down the center.
- A 1.6 mm board under an M3 × 8 screw gives engagement of 8 − 1.6 = 6.4 mm, and 6.4 / 3 = 2.1 times the screw diameter, inside the 2 to 2.5 band.
- The pilot is 7 mm deep and the screw reaches 6.4 mm, so 0.6 mm of hole remains for chips and overrun.
- Below the pilot: 9 − 7 = 2 mm of boss, plus the 2 mm wall, leaves the screw tip 4 mm from outside air; the tape stop holds that number.
- Around the pilot: (8 − 2.5) / 2 = 2.75 mm of plastic on every side of the hole.
M3 wants about 7 mm of usable boss height — 6 mm of engagement plus 1 mm of relief — so if your boss is shorter, step the fastener down a size or glue a fresh standoff beside the old one rather than gamble the wall.
Which checks prove the repair worked?
Three checks settle it: the board sits flat with no rocking, the screw holds at about 0.5 N·m without creeping deeper, and the housing wall behind each boss still shows unbroken plastic when you sight the outside face.
- Press test: push down on the corner above each boss with about 5 N of finger pressure, the weight of a 500 g mug. A sound joint does not move; a stripped pilot clicks and sinks.
- Back-out test: unscrew half a turn and drive it home again. The same torque coming back means the threads formed properly; an easier turn means the pilot is shredding.
- Outside test: run a fingertip over the housing face behind every boss. A 0.5 mm dimple means the screw tip is pressing that wall, so refit with a screw 2 mm shorter or a pilot 1 mm shallower.
- Seal test: if the housing is a rated enclosure, close it up and check the gasket line seats evenly all round before you call the job done.
Which mistakes cost you the enclosure's rating?
Three mistakes turn a watertight housing into a leak path: a drill that passes through the wall, a screw left long enough to mushroom the outside face, and a new hole punched where the molding runs thinnest.
The tape depth stop guards against the first two, because it fixes the pilot depth and the screw's reach in one move. If the bit does break through, the hole becomes a leak, and the assembly keeps its rating only once the hole is sealed. The method is in the article on sealing a wrongly drilled hole; fit a plug rated at least as high as the box, because the weakest part sets the rating. A hole added after the housing leaves the factory follows the same rule laid out in what a panel keeps after you cut it and mount devices. Ratings are manufacturer ratings: an enclosure is rated NEMA 4X / IP66 by the manufacturer; not UL listed, and it holds that rating only while every wall stays unbroken.
Decision, by what you find under the board. A boss with 7 mm or more of usable height: cut the cap, drill the pilot and screw it back, as the worked example shows. A boss cracked down its side or shorter than 7 mm: glue a new standoff beside it and keep the original as a locator. A wall breached by the bit: plug the hole with a fitting rated to match the box, or move the board into a fresh housing. Pick the case before the board layout. Lay the bosses and cutouts out for the custom builder and check the spacing in the cutout designer; the replacement arrives 10 business days from your approval of the drawing.
Catalog dimensions to compare
Compare these catalog dimensions with your component layout. Open each enclosure for its rating, material and usable space, then check those specifications against your application.
| Enclosure | Material | Outside H x W x D / display | Rating |
|---|---|---|---|
| 16 × 12 × 8 in | 304 stainless | 16 x 12 x 8 in | Rated NEMA 4X / IP66 by the manufacturer; not UL listed |
| 24 × 20 × 8 in | 304 stainless | 24 x 20 x 8 in | Rated NEMA 4X / IP66 by the manufacturer; not UL listed |
| 30 × 24 × 10 in | 304 stainless | 30 x 24 x 10 in | Rated NEMA 4X / IP66 by the manufacturer; not UL listed |
| 12 × 10 × 6 in | 304 stainless | 12 x 10 x 6 in | Rated NEMA 4X / IP66 by the manufacturer; not UL listed |
Questions
Can I rebuild the heat stake by melting fresh plastic onto the stub?
You can, and it suits a board you keep reworking. Feed a sliver of the same plastic onto the flat stub and form a cap about 2 mm thick over the board's corner, then let it cool for 2 minutes before handling. A cap that size holds a light board on a bench, but it is weaker than the molded rivet and cannot be undone, so prefer the M3 screw wherever you expect to open the housing again.
What pilot hole fits an M2.5 self-tapping screw in a slim boss?
Use a 2.0 to 2.1 mm pilot, the same 80 to 85% of major diameter the body applies to M3. Drill it 5 to 6 mm deep so engagement stays near 2 times the screw's diameter, and stop the driver near 0.3 N·m. Step down to M2.5 whenever the boss is under 6 mm across: an M3 pilot there leaves about 1.75 mm of wall against the 2.75 mm an 8 mm boss gives.
What if the drill breaks through the housing wall?
The hole becomes a leak path and the housing holds its rating only after the hole is sealed. Fit a compression plug rated IP68 into the Ø3 to Ø4 mm hole and install it as its instructions describe; a plug rated below the box's IP66 becomes the assembly's new ceiling. Skip hot glue and silicone smears: they soften near 60 to 80 °C and wash out under a hose.
Does the screwed repair survive heat and vibration as well as the original stake?
Yes, within the plastic's own limits. ABS softens near 105 °C and polycarbonate near 147 °C, and the steel screw is the strongest part of the joint, so heat that spares the housing spares the repair. Against vibration the screw beats hot glue, which creeps above 60 °C; add a flat washer under the head on a heavy board and check the torque again after the first week in service.