Order the shell as a custom part: a 316L box (aluminum when someone carries it all shift), one cutout for the 5.7 in display, three or four 22.5 mm pushbutton holes, and one M20 entry for the tether. Keep 2 in [50 mm] of clear depth behind the display for the clamp hardware. The shell itself is delivered in 10 business days from your approval of the drawing. Nobody catalogs this shape, because handheld offerings are blank pendant boxes and display carry cases, never both at once. The shell is the easy half of the build. The tether entry and the E-stop circuit decide whether the station survives a year on the floor, and that is where the engineering sits.
Where do you buy a shell for a tethered HMI pendant?
From a custom enclosure shop rather than a catalog: molded pendant boxes cover two to ten pushbuttons with no display opening, so a 5.7 in screen plus buttons and a gland base is a made-to-order shell drawn to your layout. The catalog market splits two ways, and your build sits in the gap. Suspension pendants, the overhead-crane type, are molded ABS boxes built to hang from a top fitting and hold buttons. Display carry cases hold one panel-mount screen and no operators; if that is all you need, the handheld HMI enclosure build covers the one-piece route.
A screen plus three or four buttons in one carried shell is a custom enclosure, cut from your drawing, in any material we build, from one piece. Our 7 in panel PC HMI housing shows why catalog shapes miss: 304 stainless, a VESA 100 rear and a gasketed rear cover, so its cable path is that rear cover — no place for a tether gland. The fixed machine-side version of this choice is covered in machine-mounted HMI enclosure sizing.
What rating does a carried operator station need?
A shell rated NEMA 4X / IP66 by the manufacturer — not UL listed — with the understanding that the finished pendant runs at its weakest part, and that part is usually the display's front seal, an IP65 bezel on a typical panel-mount screen. The box body is the strongest link you will buy. The front face ends up at whatever the bezel seals to when it is clamped per its drawing, which is IP65 on most industrial panels.
Pushbutton fronts carry their own IP65 seals and the gland holds IP66 through the tether, so the shell never limits the assembly. Commercial mobile panels publish the same split: about IP65 for the front in its mounting position, IP54 for the whole unit in carried use, and that is the honest target for yours. The NEMA 4X versus IP66 comparison untangles the two systems. One line for your spec sheet: NEC 110.28 keeps an IP code from satisfying a US spec written in NEMA types, so write both, and remember neither number means anything until the parts are mounted in the box.
Stainless or aluminum when the operator carries it all shift?
316L for washdown and salt air, powder-coated aluminum for all-day carrying: at the same 1.5 mm wall, aluminum's 2.7 g/cm³ against stainless' 7.9 g/cm³ takes about 66 % off the shell metal. The arithmetic decides it. A 10 x 8 x 3.5 in shell wraps about 0.18 m² of sheet, and at 1.5 mm that sheet weighs 0.18 × 0.0015 × 7900 ≈ 2.1 kg in 316L, or 0.18 × 0.0015 × 2700 ≈ 0.7 kg in aluminum. That 1.4 kg comes straight off the wrist before you bolt on a display that weighs about a kilogram itself, so the stainless build lands near 3.3 kg and the aluminum near 2 kg.
Match the grade to the plant the way the catalog splits: 304 for indoor washdown and food areas, 316L for salt air, brine and chemical zones, aluminum and polycarbonate where weight wins. Seal either metal with an EPDM gasket, good from -50 to 150 C and happy in hot water and cleaning chemicals.
How big is the shell for a 5.7 in display and four buttons?
About 10 x 8 x 3.5 in [254 x 203 x 89 mm] outside: that front fits the display with button centers 40 mm apart, and the depth swallows 2 in [50 mm] of display clamps and 55 mm of contact block behind the operators. The 22.5 mm hole is the industry-standard operator hole, and most 22.5 mm operators clamp fronts from 1 to 6 mm thick. Hold centers at least 30 mm apart, 40 mm when operators wear gloves, and keep 10 mm of flat material between cutouts so the front stays stiff under the bezel gasket. Cutting four holes and blanking the fourth with a 22.5 mm plug rated IP66 costs nothing at order time. For choosing and sealing the operators themselves, sealed pushbutton control station selection is the companion piece.
Then check heat, because a carried box is a small sealed one. A 5.7 in panel draws about 8 W. The 10 x 8 x 3.5 in shell has about 0.18 m² of surface, and stainless sheds heat at 3.7 W/m²·K, so the box rejects 3.7 × 0.18 = 0.67 W per degree and the internal rise is 8 / 0.67 ≈ 12 C. At a 25 C plant the inside sits near 37 C, inside the 40 C that electronics are good for without a datasheet that allows more. Move the 24 V supply into the machine cabinet before you order: its 5 W of loss takes the load to 13 W, the rise to 13 / 0.67 ≈ 19 C and the inside to about 44 C, past the limit. Carried through moving air, the real rise runs lower; still air is the design case.
How should the tether leave the shell?
Through one M20 entry in the bottom face, with a gland sealing the jacket and a mesh strain-relief sleeve behind it carrying the pull, so no load ever reaches a soldered or screw terminal. Size the gland to the measured jacket diameter: M20 glands ship with insert ranges that together span about 3 to 13 mm OD, and a 17-core shielded flex tether at about 9 mm lands mid-range. The hole for the M20 locknut is 20.5 mm [0.81 in], and the M20 gland hole size guide covers thin-wall metal in detail. Clamp the jacket, never the conductors or the shield; a mesh grip bears along its whole sleeve, which is what a station set down by its cable needs, and strain relief for sealed enclosure entries lays out the hardware.
Respect the cable's own numbers. Typical control-cable datasheets put the minimum bend radius at 7.5 times the jacket fixed and 15 times flexed, so a 9 mm tether wants 135 mm of radius where it moves — hold its first 150 mm straight below the grip. Land the shield at the machine end only, on the cabinet ground bus, and bond the metal shell through a ground conductor; enclosure grounding and bonding shows the terminations. For the machine-side run through tray or conduit, M20 gland selection for armored control cable walks the same sizing steps with armor clamping.
How do you wire an E-stop on a portable station?
As a latching red mushroom on yellow in one of the 22.5 mm holes — the standard 40 mm mushroom takes the same hole as every other operator — opening two separate channels that the machine side monitors for agreement. IEC 60204-1 sets the behavior in plain terms: an emergency stop is a stop category 0 or 1, it latches, and resetting it never restarts the machine. Put reset acceptance on the machine, not on the pendant.
Use positively guided contact blocks behind the actuator, run the two channels as separate conductor pairs in the tether, and let the risk assessment to ISO 13849-1 set the performance level the pair must reach. Wiring the channels as a series hardwired loop gives you pendant-loss behavior built in: snap a core or pull the tether out, and the loop opens into the safe state. That property makes a hardwired tether simpler than a connector for safety circuits. Your start and stop buttons are ordinary momentary operators wired home to the machine, and if they command a drive, the three-wire seal-in pattern for momentary pushbuttons on a VFD shows the hold-in wiring. After the build, prove it once with power on and the machine idle: strike the mushroom, confirm the stop and the latched reset, then open the tether at the machine terminals and confirm the machine sees the loss.
What goes on the order?
One drawing, one shell, every hole dimensioned: front with the display cutout from the HMI maker's drawing and four 22.5 mm holes, one 20.5 mm M20 entry in the bottom, material, outer size and finish all written down. The cutout designer lays the holes out, checks spacing and sends the layout with your quote request, on catalog sizes or a custom size. Attach the HMI's dimensional drawing — the cutout, clamp depth and bezel seal profile come from it, not from the screen's diagonal. The build starts when you approve the drawing we send back, and delivery is 10 business days from that approval, anywhere in the world. Quote the rest of the assembly as separate lines: operators, contact blocks, the E-stop actuator, gland, mesh grip, tether cable and the cradle that parks the station.
| On the order | Write this | Why |
|---|---|---|
| Material | 316L, powder-coated aluminum, 304 or polycarbonate | aluminum saves about 1.4 kg at 1.5 mm wall |
| Rating | NEMA 4X / IP66 by the manufacturer, not UL listed | front face runs at the bezel's IP65 |
| Outer size | 10 x 8 x 3.5 in [254 x 203 x 89 mm] | 2 in of clamps, 55 mm of contact block, wire room |
| Front | display cutout per the HMI drawing; four 22.5 mm holes, 40 mm centers | 30 mm minimum, 40 mm for gloves |
| Tether entry | 20.5 mm hole, bottom face; M20 gland plus mesh grip | 9 mm OD tether, 135 mm flex radius |
| Gasket | EPDM, -50 to 150 C | hot water and cleaning chemicals |
| Heat | 8 W display inside, 24 V supply in the machine cabinet | 12 C rise, about 37 C inside at 25 C plant |
Decision by duty. Washdown line with chlorides or salt air: 316L, 10 x 8 x 3.5 in, four holes, mesh grip on the tether. Indoor machine carried all shift: powder-coated aluminum on the same drawing. Bench or cradle station that rarely leaves the machine: 304 stainless. If the job only has to carry a display with no operators, custom enclosures for portable electronics and the handheld build above are the lighter routes.
Enclosures in this article
| Enclosure | Material | Outside H x W x D / display | Rating |
|---|---|---|---|
| 7" HMI enclosure | 304 stainless | 7.43 x 9.96 x 3.7 in | IP65-type front seal with the display installed, manufacturer rated; not UL listed |
Questions
Can I start from a suspension pendant enclosure and carry it instead?
Mostly no. Suspension boxes are high-impact ABS, typically rated NEMA 4X by their makers, molded for two to ten pushbuttons with a top hole for the hanging fitting. There is no display cutout, no flat land for a bezel gasket, and the wall was never drawn to carry the station's weight at a bottom gland, which is exactly the load a carried tether applies.
How many cores does the tether need for display, buttons and E-stop?
Count them: two for the 24 V pair, eight for Ethernet, three for start, stop and common, two for the E-stop channels and two spare makes 17 cores. A shielded flex cable of 17 cores in 0.34 to 0.75 mm² runs about 9 mm in diameter, mid-range for an M20 gland insert. Drop Ethernet for RS-485 and the comms pair becomes three cores, twelve in total.
Does the tether need its own overcurrent protection?
Yes, at the machine end. The 8 W display draws 8 / 24 = 0.33 A, but a tether snagged in the machine can short the pair, and the fault should clear where the supply lives. A 2 A breaker or fuse in the machine cabinet covers the pendant with margin and stops a pinched jacket from cooking. 24 V DC sits below the usual 60 V DC shock threshold; the fuse is there for the cable.
Can I cut the fourth pushbutton hole later in the field?
Cut it now and blank it. A 22.5 mm blanking plug rated IP66 seals the spare hole from the front, and you swap it for an operator in minutes. Drilling 22.5 mm through a finished stainless front risks burrs under the bezel gasket and swarf across the electronics, so the hole belongs on the order drawing, not on a maintenance day.
How long can the tether run?
Ethernet holds to 100 m per the standard; RS-485 runs past 1 km at 9.6 to 115 kbps. The 24 V drop is small: 0.33 A through a 30 m loop (15 m out and back) of 0.75 mm² copper at about 0.023 ohm/m gives 0.33 x 0.69 = 0.23 V. The real limit is ergonomic — keep the tether under about 15 m so it cannot drag the station into the machine envelope.