Build both halves from one controlled master, then release each half as a separate solid. Keep the outer shape, cavity and mating datums upstream. Add half-specific fasteners and manufacturing details downstream. This avoids maintaining two independent copies of a complicated surface model. If your CAD system lacks associative body extraction, use revision-controlled neutral exports through its supported tools. Treat those exports as snapshots, not automatically updating references.
What you need before splitting the shell
Start with the manufacturing process, not the split command. A sculpted housing suitable for molding may require substantial redesign for folded stainless construction. Machining, molding and sheet-metal fabrication need different wall, joint and fastening details.
Prepare these inputs before creating the production halves:
- The approved exterior envelope and internal equipment envelope.
- A common origin, orientation and set of reference planes.
- A proposed parting plane or parting surface.
- Wall thickness targets appropriate to the manufacturing process.
- Joint requirements: locating, fastening, sealing and service access.
- Manufacturing tolerances and the required assembly clearance.
- A supported method for extracting bodies or exporting neutral solids.
A master model can contain complex surfaces without containing every production detail. Keep cosmetic features, individual screw holes and half-specific machining out of the shared definition where practical.
Use only features available under your installed CAD license. Check the software manufacturer's documentation for supported extraction, import and export methods. The geometry strategy should not depend on an unavailable extension.
Build the halves from one controlled master
-
Establish the assembly coordinate system. Place the housing relative to meaningful installation features, such as its mounting face or equipment centerline. Define a primary reference plane and two perpendicular references. Give them stable names. Do not use a convenient curved face as the only positioning reference.
-
Create the master exterior and cavity. Build the ergonomic exterior once. Define the internal cavity from component space, wall requirements and cable access. For a continuous cavity, subtract it from the exterior solid before splitting. Check tight curves for offset failures and local wall thinning. A successful shell operation alone does not prove manufacturability.
-
Define the shared parting geometry. Use one plane or surface to divide the master wall volume. Check that it crosses the intended walls without creating unwanted fragments. Review small faces, sharp transitions and the direction in which each half must separate. A curved seam may look suitable while trapping internal features during assembly.
-
Split the wall volume into separate bodies. Retain both results and identify them consistently, such as upper and lower. At this stage, their cut faces can meet at the theoretical interface. That shared boundary establishes position; it does not yet provide production clearance, gasket space or a fastening flange.
-
Create separate production parts. Use a documented derived-body or extraction feature when available. Otherwise, export each selected body as a neutral solid, preferably STEP when supported by both systems. Verify the export contains only the intended body. Keep the master revision, export settings and destination part recorded together.
-
Add the mating interface deliberately. Create the locating lip, groove, flange or gasket seat from the shared datums and controlled dimensions. Keep references flowing from the master to each half. Avoid making the upper half depend on the lower half while the lower also depends on the upper. Circular references make changes difficult to predict.
-
Add half-specific production features. Place screw access, inserts, bosses, mounting holes and cable openings in the appropriate part. Check their relationship to the cavity and joint. For folded construction, review bends, tool access and joining sequence before treating the solid as a fabrication definition.
-
Assemble and issue a matched revision. Position both halves using the shared coordinate system or stable datums. Rebuild the assembly and check the interface after every master change. When exports are non-associative, replace both snapshots from the same master revision. Never assume an older companion half still fits.
A native derived part may retain a dependency on the master even when its own feature tree looks short. A neutral import usually removes that native feature history, but also removes the automatic update relationship. Choose consciously between dependency management and manual revision control.
Set clearance from the manufacturing process
The split surface defines where the halves meet mathematically. The joint design defines how manufactured parts actually fit.
Separate three requirements:
- Location: which surfaces establish lateral position and orientation.
- Closure: which stops or flanges determine the final assembled position.
- Sealing: which surfaces control the gasket's working compression.
Do not make every opposing surface a tight locating fit. Multiple tight fits can fight each other when dimensions vary. Allow non-locating surfaces enough clearance for the specified process and expected distortion.
For an illustrative machined joint, consider a groove width of 0.130 in [3.30 mm] and a tongue width of 0.120 in [3.05 mm]. Nominal total width clearance is 0.010 in [0.25 mm], not that amount on each side.
If each width has a tolerance of ±0.004 in [0.10 mm], worst-case total clearance ranges from 0.002 to 0.018 in [0.05 to 0.46 mm]. That calculation excludes position error, angular error, finish buildup and distortion. These example dimensions are not recommendations for molded or folded parts.
For a sealed joint, set the closed gasket gap from the gasket supplier's compression limits. Include flange flatness, fastener spacing and dimensional variation. The tongue-and-groove gasket design article covers that interface beyond the basic shell split.
Check the assembled pair before release
Inspect the pair in assembly, not only as isolated part files. Use section views across corners, fasteners, cable entries and changes in seam direction.
Confirm the following before release:
- Each finished half contains the intended solid, with no unintended floating bodies.
- Minimum wall thickness remains acceptable around curved transitions and local details.
- Hard parts do not interfere throughout the assembly and removal path.
- Locating features engage before vulnerable seals or connectors take assembly loads.
- Fasteners have installation access, adequate engagement and clearance from internal equipment.
- Cable routing and service loops remain clear of the closing joint.
- Gasket compression remains within its specified range across the tolerance stack.
- Both released files use the same units, origin, orientation and master revision.
Run the generated enclosure CAD solid-geometry checks on the exported files, not just the native models. Reimporting an export can expose translation problems before manufacturing receives it.
For broad sealing flanges, review the enclosure cover flatness and gasket compression article. Nominally matching CAD faces cannot account for fabrication distortion or uneven closure loads.
Mistakes that break the joint or its seal
Duplicating the entire feature tree into two independent parts creates two places to repair every exterior change. Keep one authoritative shape definition instead. If independent copies are unavoidable, document their common revision and do not edit shared geometry separately.
Treating an imported solid as a live reference leaves one half unchanged after its companion moves. Mark neutral imports as controlled snapshots. Update and inspect the pair together.
Deleting arbitrary faces to make clearance can move the wrong functional boundary. Dimension clearance from named datums and identify whether it is total, radial or per side.
Using the gasket as the only locating feature can introduce shear, uneven compression and assembly variation. Provide appropriate mechanical location without obstructing the sealing path.
Assuming a split shell carries an enclosure rating skips evaluation of the completed joint. Fasteners, seals, openings and assembly instructions all matter. Our enclosure ratings are manufacturer ratings; our enclosures are not UL listed.
For repeat production, establish the first approved pair as a controlled assembly. The custom enclosure prototype workflow explains how to carry approved details into later builds.
What to send for manufacturing review
Send an assembly model plus separate solids for both halves. Include a dimensioned drawing because neutral geometry alone does not communicate tolerances, gasket compression or inspection requirements.
Identify these items in the release package:
- Master revision and matching part revisions for both halves.
- Units, shared coordinate system and part orientation.
- Material, manufacturing process and nominal wall requirements.
- Overall width, height and depth, clearly identified as external dimensions.
- Parting geometry, locating datums and critical interface tolerances.
- Fastener details, gasket requirements and intended opening direction.
- Every cutout, mounting feature and required internal clearance.
- Environmental exposure and any required enclosure rating or project listing.
The custom enclosure quote without CAD article covers supplementary sketches and dimensions when the model package is incomplete.
For fabricated electrical housings, we build custom enclosures from one piece, with customer-defined material, dimensions and cutouts. Our custom stainless enclosure and cutout review covers 304 and 316L starting points and drawing requirements. Confirm that the proposed split-shell geometry suits the fabrication process before approving the drawing.
Enclosures for this job
Catalog sizes that suit the job this article answers, picked from its subject; open one for its full specifications.
| Enclosure | Material | Outside H x W x D / display | Rating |
|---|---|---|---|
| 12 × 10 × 6 in | 304 stainless | 12 x 10 x 6 in | Rated NEMA 4X / IP66 by the manufacturer; not UL listed |
| 20 × 16 × 8 in | 304 stainless | 20 x 16 x 8 in | Rated NEMA 4X / IP66 by the manufacturer; not UL listed |
| 24 × 20 × 8 in | 304 stainless | 24 x 20 x 8 in | Rated NEMA 4X / IP66 by the manufacturer; not UL listed |
Questions
Can I create mating enclosure halves without an advanced assembly extension?
Yes, if your installed software supports the necessary modeling and export operations. Build the shared shape once, split it into bodies, and extract or export each half using documented features. Neutral exports provide a practical snapshot workflow, but you must manage updates and matching revisions manually.
Should I shell the enclosure before or after splitting it?
For a continuous cavity, creating the wall volume before splitting often keeps the internal shape consistent. Split first when the halves require substantially different cavity construction. Either approach needs checks for minimum wall thickness, failed offsets, manufacturing access and features that obstruct assembly.
How much clearance should mating enclosure halves have?
No universal clearance suits every process. Base the gap on dimensional tolerances, position errors, distortion, finish thickness and assembly needs. State whether a clearance is total or per side. Keep gasket compression requirements separate from the clearance used to locate and assemble the hard parts.
Will STEP files keep both enclosure halves automatically synchronized?
Not through ordinary neutral geometry exchange. A STEP import generally carries geometric bodies rather than the source model's native feature relationships. After a master change, export the affected halves again, update their revisions and inspect the complete assembly before releasing the replacement files.