Manufacturing an enclosure with projecting features

Use formed sheet for accessible bends, machining for integral features with reachable surfaces, and welded construction only with a suitable alloy and defined joints. Specify the exact material, projection geometry, service loads and sealing requirements before requesting a quote.

NEMA4 Enclosure engineering team · Published October 31, 2026 · 7 min read

Choose formed sheet when the projections can be bent from an accessible blank. Choose machining when integral bosses, ledges or accurate mounting faces justify removing material. Choose a welded assembly only after confirming the exact alloy, joint access and distortion limits. A feature that appears suspended in a model needs a defined load path, not necessarily special tooling. Before requesting a quote, show how every projection connects to the enclosure and which surfaces must remain sealed or accurately located.

What projecting geometry means for manufacturing

A projection can be a folded flange, an internal shelf, a mounting boss or an overhanging bracket. Those shapes may look similar in a rendered model, but they require different manufacturing access.

Separate two questions. Can the feature support its service load? Can the chosen process reach every surface and joint needed to make it?

A cantilever is attached at one end and carries load away from that attachment. An undercut is geometry hidden behind another surface from a particular tool direction. A feature can be both, but structural strength and tool access need separate reviews.

Construction route Geometry that suits it Main constraint to resolve
Formed sheet Flanges, returns and brackets with accessible bend lines Bend sequence, tool clearance and material formability
Machined body Integral bosses, pockets, ledges and accurate mounting faces Cutter access, tool reach and remaining wall stiffness
Welded assembly Separate plates or brackets joined into a larger structure Alloy weldability, joint access, distortion and inspection
Mechanically assembled parts Removable shelves, brackets and serviceable internal features Fastener access, loosening resistance and sealing where penetrated

Mark a section through each overhang. Show its root, surrounding walls and the opening through which tooling would enter. An isometric view alone rarely answers those questions.

For folded chassis structures, the discussion of sheet metal rack chassis design covers the wider production decisions. Here, the deciding issue is how each projecting feature can actually be formed, cut or joined.

When formed sheet is the practical route

Formed sheet works well when the projection can become a flange or a separate bent bracket. It usually avoids machining a large pocket simply to leave a small shelf behind.

The flat pattern must contain enough material for the bends and their reliefs. The forming sequence must also leave space for the punch, die and already formed walls.

An inward return near the bottom of a deep enclosure can block later bends. Moving a bend, splitting the body or using a separate bracket may solve that obstruction. Specialized tooling can expand the options, but it does not eliminate every collision.

Do not assign a universal inside bend radius based only on sheet thickness. The acceptable radius depends on alloy, temper, thickness, grain direction and the forming process. Ask for a proposed radius before freezing nearby holes or mating dimensions.

Specify critical relationships from functional datums rather than through a chain of bend dimensions. For example, locate a mounting face relative to the backplate seating surface if those parts must align.

A separate bracket also introduces fasteners and assembly access. If that bracket must be removable, review enclosure lid fasteners for repeated access for relevant retention and serviceability considerations. Do not place a captive fastener where its installation tooling cannot reach.

When machining is worth the material removal

Machining can leave projections integral with the enclosure body. That removes an assembly joint and can locate several mounting faces in one setup.

The benefit depends on access. A cutter approaching through an open top can produce pockets and bosses, but it cannot automatically reach beneath every internal ledge. A different setup, an angled approach or a suitable undercut tool may be needed.

Additional machine axes change the available tool directions. They do not make a completely obstructed surface accessible through solid material.

Deep, narrow pockets create another limit. Longer tools deflect more, and thin walls can move during cutting or after unclamping. Tight tolerances on those walls can require different fixturing, a revised machining sequence or thicker sections.

Inside corners also retain a radius from the cutting tool. Specify a sharp internal corner only when the mating part truly requires it. A relief in the mating component may avoid a difficult secondary process.

Identify which surfaces require machining accuracy and which only need clearance. Applying the tightest tolerance everywhere can change the process without improving the assembly.

A machinable-looking model must still contain valid connected geometry. Use solid geometry checks for enclosure CAD to catch disconnected bodies and invalid intersections before requesting process feedback.

When a welded assembly needs a different specification

A welded construction can create projections from separate plates, tubes or brackets. It may be practical when machining would remove substantial material or forming would trap the tooling.

However, “2000-series aluminum” is not a sufficient welding specification. Weldability differs substantially within that alloy family, and the temper affects the starting material properties.

For example, 2024 is generally unsuitable for conventional fusion-welded structural construction because of cracking susceptibility. Other alloys in the family, including 2219, can be welded using an appropriate procedure. Neither example establishes suitability for an unspecified enclosure.

State the exact alloy designation and temper before asking whether welding is feasible. If substitution is allowed, define the properties that must remain unchanged: strength, corrosion performance, conductivity, weight or dimensional stability.

Welding can soften heat-treated aluminum near a joint and can distort nearby mounting or sealing faces. Do not calculate the finished structure using parent-material strength everywhere without accounting for the joining process.

The joint drawing should identify:

  • Which parts are joined and which faces must remain accessible during welding.
  • Whether each weld carries load, closes a leak path or serves both functions.
  • Weld extent, required joint preparation and any permitted interruptions.
  • Critical dimensions after welding and any required finish machining.
  • Inspection and acceptance requirements appropriate to the joint's function.

Do not specify an intermittent weld along a seam that must form a continuous environmental barrier. Conversely, do not add continuous welds everywhere without considering heat input and distortion.

Document separate brackets and their material requirements in the enclosure bill of materials. A solid model showing touching parts does not define a welded joint.

What a process review proves and what it does not

A manufacturing review establishes whether a proposed sequence can produce the required geometry. It should address tooling access, forming limits, workholding, joining access and measurable finished dimensions.

That review does not automatically establish structural capacity, environmental protection or electrical compliance. Each needs its own requirements and supporting evidence.

A successful weld inspection, for example, does not by itself demonstrate that a completed enclosure excludes water. A dimensional inspection does not establish fatigue life under vibration. A visually continuous seam can still contain a leak path.

For our custom enclosures, ratings are manufacturer ratings for the specified design; the enclosures are not UL listed. Changing the construction, adding a penetration or moving a sealing surface requires review of the resulting design.

Specify the required environmental performance before choosing the joint arrangement. Then define how the completed enclosure will be evaluated, including its door, gasket, entries and mounting details.

Do not treat a leak check as evidence that an enclosure is suitable for pressure service. Pressure containment requires a separate design basis outside ordinary electrical enclosure construction.

What projections change inside the panel

A projection consumes more than its visible volume. It also needs clearance for installation, wiring, tools and eventual replacement of nearby components.

Check the assembly sequence with the largest component installed. A shelf that clears an empty housing may prevent a terminal screwdriver or cable connector from reaching its working position.

The projection's root also needs a load calculation. For a hypothetical load of 22 lbf [98 N] acting 2 in [51 mm] from the root, the bending moment is approximately 44 lbf·in [5.0 N·m]. That excludes shock, vibration and any additional cable force.

Give the load direction and operating conditions, not just the component mass. A cantilever supporting a stationary terminal strip differs from one carrying equipment on a vibrating machine.

Keep projections away from gasket compression zones unless their effect is deliberately controlled. Welding or fastening a bracket near a sealing flange can change flatness or create a penetration that needs sealing.

Internal shelves can also obstruct airflow and create local hot spots. Confirm component clearances and the thermal arrangement after adding brackets, rather than checking only the enclosure's outside dimensions.

What to specify before requesting a quote

Send a functional drawing package, not a request to manufacture an unexplained shape by any available process. Separate mandatory geometry from features that can change to improve access or reduce joining.

Drawing or quote item Information to provide
Material Exact alloy or stainless grade, temper where relevant, thickness and permitted substitutions
Overall envelope Width, height and depth, with the dimension convention clearly identified
Projection geometry Root location, length, thickness, underside clearance and section views
Functional surfaces Mounting faces, sealing lands, datums and genuinely critical tolerances
Service loads Force or mass, load direction, lever arm, vibration and handling conditions
Construction freedom Whether a projection must be integral or may be bent, bolted or welded
Joints Joint purpose, access, weld extent, fastener requirements and inspection expectations
Environment Water exposure, chemicals, temperature and required enclosure protection
Finish Surface condition, coating requirements and faces that must remain suitable for bonding
Assembly access Component insertion path, tool clearance, cable routes and removable parts

We build custom enclosures with customer-defined material, width, height, depth and cutouts, from one piece. That offering does not establish that every machined overhang or welded aluminum structure is available. Submit the geometry and material requirements for review before committing to a manufacturing route.

If the projection is actually a mounting need that can be met with a separate bracket, say so. For a stainless body requiring openings rather than complex integral features, custom stainless enclosures and factory cutouts provide a more relevant starting point.

Once the construction route is agreed, complete enclosure drawing verification before fabrication. The approval drawing should capture the agreed geometry, material and joins, rather than leaving those decisions to fabrication.

Enclosures for this job

Catalog sizes that suit the job this article answers, picked from its subject; open one for its full specifications.

EnclosureMaterialOutside H x W x D / displayRating
12 × 10 × 6 in304 stainless12 x 10 x 6 inRated NEMA 4X / IP66 by the manufacturer; not UL listed
20 × 16 × 8 in304 stainless20 x 16 x 8 inRated NEMA 4X / IP66 by the manufacturer; not UL listed
24 × 20 × 8 in304 stainless24 x 20 x 8 inRated NEMA 4X / IP66 by the manufacturer; not UL listed

Questions

Can any 2000-series aluminum enclosure be welded?

No. Weldability varies within the 2000 series, so the exact alloy and temper must be identified. Some alloys are generally unsuitable for conventional fusion-welded structures, while others can be welded using an appropriate procedure. The finished design must account for joint strength, heat-affected material, distortion and corrosion exposure.

Can CNC machining produce every internal overhang?

No. Machining requires a physical tool path to each surface. An overhang may need another setup or specialized tooling, and some enclosed geometry remains inaccessible. Show section views and allow alternative constructions where an integral feature is not essential to the enclosure's function.

When should a projection become a separate bracket?

A separate bracket is worth considering when it improves tool access, allows replacement or avoids extensive machining. Define its load, fastener access and resistance to loosening. If its attachment penetrates the enclosure wall, the completed entry also needs appropriate sealing and environmental review.

What information is needed to quote an enclosure with projecting features?

Provide the exact material, overall dimensions, section views through projections, critical mounting surfaces and service loads. Identify whether integral construction is mandatory or whether forming, bolting or welding is acceptable. Include environmental requirements and distinguish essential tolerances from dimensions that may change during manufacturing review.

Checklist before you order

Specify it once, built to your drawing

  • Environment and NEMA type: Type 1, Type 3R, Type 4, Type 4X, Type 6P, Type 12, Type 13 (manufacturer ratings, not UL listed)
  • Material: 304 stainless steel, 316L stainless steel, Powder-coated carbon steel, Aluminum, Polycarbonate, Fiberglass (FRP)
  • Size: inside or outside height, width and depth, with the depth your deepest component needs
  • Cutouts, glands and windows, dimensioned from one datum on each face
  • Mounting and access: wall, pole or stand, hinge side, mounting panel
  • Quantity: from one piece

Delivered in 10 business days, anywhere in the world. Counted from your order; for custom work, from your approval of the drawing.

Build it from 12 × 10 × 6 inRequest a custom quote

NEMA 4X enclosures: sizes for this job

Keep reading

More on specifying and ordering

All articles

Buying guides

The guides behind this answer

All guides