Short answer: a CAN-to-Ethernet gateway, protocol converter or DIN-rail I/O module whose EMC declaration lists only IEC 61000-6-2 or IEC 61326-1 is an industrial device. Bridge equipment is surveyed against IEC 60945, the standard for maritime navigation and radiocommunication equipment, and a unit with no test report to that environment comes off the bridge. Mount it in a stainless cabinet in the equipment room or engine control space instead, and cross the bridge boundary with tested equipment or passive media such as a fiber run. If the gateway must sit on the bridge itself, send the supplier the exact marine environment class and ask for a delta-test quote.
Is an industrial EMC declaration accepted on a ship's bridge?
No. A declaration listing only IEC 61000-6-2 or IEC 61326-1 documents tests in industrial or general locations, while bridge equipment is surveyed against IEC 60945, and a device with no report to that environment has nothing to present. The failure mode is procurement, not physics. The gateway is specified, wired and commissioned, then at survey the maker confirms in writing that no marine bridge EMC tests were performed, and the units come out. The hardware might pass if it were tested; an untested product has no report, so the outcome is fixed before the surveyor arrives. Read the declaration of conformity before the purchase order, and treat anything declared to those two standards as industrial-only however robust the design looks.
Keep three questions apart: the device's EMC report, the panel's listing, and the enclosure's rating. The panel's listing is its own subject, covered in the enclosure listing for a control panel article, and the enclosure side is what the rest of this page sets out.
What do IEC 61000-6-2 and IEC 61326-1 actually cover?
IEC 61000-6-2 is generic immunity for apparatus in industrial locations, and IEC 61326-1 covers measurement, control and laboratory equipment below 1000 V AC or 1500 V DC; neither standard claims shipborne conditions.
| Standard | What it covers | What it gives you on a bridge |
|---|---|---|
| IEC 61000-6-2 | Generic immunity for apparatus in industrial locations: sites fed from their own HV or MV transformers, plus battery-operated industrial equipment. Continuous and transient, conducted and radiated disturbances from 0 Hz to 400 GHz, ESD included | An immunity baseline for factories, the fallback when no product standard exists |
| IEC 61326-1 | Measurement, control and laboratory equipment below 1000 V AC or 1500 V DC, in industrial and non-industrial locations. The third edition (2020) extended radiated immunity up to 6 GHz | A test scope for the equipment category, with no maritime location in it |
| IEC 60945 | General requirements for maritime navigation and radiocommunication equipment: environmental durability, EMC, safety and ergonomics, which the equipment performance standards call on | The environment the bridge surveyor asks about |
The scope wording is the tell. IEC 61000-6-2 defines an industrial location by its supply and its disturbance profile, meaning a plant fed from its own transformer. A bridge sits among navigation radars, VHF, MF and HF transmitters and gyro electronics, a different disturbance profile that neither standard claims to represent. For the industrial suite itself, the IEC 61000-6-2 EMC compliance checklist for machinery page walks those immunity tests.
Marine EMC is also not one thing. A device in a machinery space, a device on an exposed deck and a device on the bridge are assessed against different environment classes in the marine framework. Get the standard, the edition and the environment class in writing from the class society or flag administration before you order a test or accept a vendor report.
What does a bridge surveyor ask for that an industrial report lacks?
The full test report, mapped item by item against the marine list: the report, not the declaration, lists test levels, the ports exercised, the performance criterion and every degradation observed. IEC 60945 sets the environmental, EMC, safety and ergonomic tests that bridge equipment must pass, and the performance standards for navigation and radiocommunication equipment call on it. The typical gaps between an industrial report and the bridge list are:
- Radiated RF immunity: the test level and the frequency span it covers
- Conducted RF on signal and supply ports
- Surge and burst levels on the DC supply and the data ports
- ESD, both contact and air discharge
- Supply variation and interruption on the vessel's DC bus
Emissions count in both directions. A gateway's switching supply and Ethernet PHY can desense a VHF receiver across the console, so read the radiated emissions limit line in the report and the receive bands it protects. Confirm also that the CAN, Ethernet and DC ports were exercised while carrying live traffic; a port tested idle proves little.
Where does the gateway cabinet go when the device is industrial-only?
Outside the bridge boundary: an equipment room, a converter cabinet or the engine control space, with only tested equipment or passive media crossing onto the bridge. Relocation changes the assessed location, which is the one lever the enclosure gives you; the device and its declaration stay exactly as they were. This is the same line drawn in putting an indoor gateway in an outdoor enclosure: the box answers the water and corrosion question, and the device's test status travels with the device.
For the cabinet itself, 316L stainless is the marine answer, and the tinned wire and terminals in a marine engine control cabinet article covers the conductor side. A deck-mounted box comes from the stainless outdoor enclosures range, and wall mounting follows the enclosure mounting guide.
How hot does a sealed stainless cabinet run with a gateway inside?
With about 15 W dissipation in a 24 x 20 x 10 in [600 x 500 x 250 mm] stainless box the interior rises roughly 4 K above ambient, so a 35 C equipment room holds it near 39 C, under the 40 C limit for most electronics. Example inputs follow; replace them with your datasheet watts before you select a box.
- Gateway: 3 W
- Five-port Ethernet switch: 10 W
- 24 V DC supply delivering 13 W at 88 % efficiency: losses = 13 x (1 / 0.88 - 1) = 1.8 W
- Total: 3 + 10 + 1.8 = 14.8 W, call it 15 W
Surface area by the usual wall-mount formula, with width 0.60 m, height 0.50 m and depth 0.25 m:
A = 1.8 x (0.60 x 0.50) + 1.4 x (0.60 x 0.25) + 1.6 x (0.50 x 0.25) = 0.54 + 0.21 + 0.20 = 0.95 m2
Rise above ambient, with the stainless wall coefficient k = 3.7 W/m2K:
dT = 14.8 W / (3.7 W/m2K x 0.95 m2) = 14.8 / 3.52 = 4.2 K
Interior at a 35 C ambient: 35 + 4.2, about 39 C. That leaves roughly 1 K of margin under the limit, which is one more reason this cabinet lives in an equipment room rather than on a sun-loaded deck, where solar gain erases the margin. A PWM drive sharing the cabinet rewrites the load completely: size from its dissipation curve before adding one.
What do you ask the supplier before you order?
Two things in writing: the list of every EMC standard and edition the product was tested to, with report numbers and dates, and a quote for a delta test against the marine environment you name. Work through four items:
- The environment itself: standard, edition and class (bridge, deck or machinery) in writing from the class society or integrator.
- The full EMC test report: test levels, port list, operating mode during each test, performance criteria and observed degradations.
- A gap list: every marine item the report leaves uncovered, written out one line at a time.
- The delta-test quote. The maker's EMC group scopes only the missing items, and because the industrial report already covers most of the basic suite, a delta test is far cheaper than full requalification.
A quote with a date before your installation window means you schedule the test and keep the gateway on the bridge. No quote, or a date after commissioning, means you relocate the cabinet as above and cross with tested or passive media.
How do you wire the cabinet so the installation performs?
Segregate power from signal, land every data shield with a 360-degree bond, and bond the backplate, DIN rail and door to the box wall with short bare-metal straps. De-energize and lock out the cabinet before you land any bond or shield.
| Measure | What it does |
|---|---|
| Power and signal in separate ducts, crossing at 90 degrees where they must cross | Stops capacitive and inductive coupling into the CAN and Ethernet runs |
| Shielded cable on data runs, shield clamped 360 degrees in an EMC gland or bonding clamp | Holds the shield's high-frequency performance; a pigtail lands it on a wire, which loses it |
| Bare-metal bonds between enclosure, mounting plate and DIN rail | Gives filters and shields the low-impedance return they were tested with; the enclosure grounding and bonding guide covers the connections |
| Ferrite cores on cables entering and leaving the cabinet | Suppresses common-mode transients on supply and data leads |
| A drive sharing the space: its specified shielded motor cable and EMC filter | Holds the drive's declared EMC category; unshielded motor cable is the dominant emitter in most cabinets |
These measures make the tested performance real in the field. They complement the report; the surveyor still asks for the report itself. Before sign-off, run the checks in the VFD EMC field check article, because the same field discipline applies to a gateway cabinet.
What goes on the enclosure order?
A 316L stainless wall-mount box rated NEMA 4X / IP66 by the manufacturer, not UL listed, with the removable mounting plate, EMC cable entries and the size your heat check passed.
| Item | Specify | Why |
|---|---|---|
| Material | 316L stainless | Salt air and washdown in machinery spaces and on deck |
| Rating | NEMA 4X / IP66, manufacturer-rated | Spray and corrosion protection for the relocated cabinet |
| Size | From your heat check, with margin for anything added later | The worked example passed with 15 W inside |
| Entries | EMC glands or shield-bonding clamps for data, plated hubs for power | Lands shields 360 degrees at the box wall |
| Mounting plate | The removable panel, bonded to the enclosure wall | Carries the DIN rail and the low-impedance bond |
| Conductors | Tinned copper, per marine practice | Matches the machinery-space wiring in the marine cabinet article above |
| Delivery | Custom sizes delivered in 10 business days, counted from your approval of the drawing | The build promise for one-off sizes |
Choosing by environment and inside dimensions? The enclosure selector carries your conditions to a custom quote. Run the heat check first, because a dimensional match says nothing about temperature, and the relocation only works if the gateway inside stays under its limit.
Catalog dimensions to compare
Compare these catalog dimensions with your component layout. Open each enclosure for its rating, material and usable space, then check those specifications against your application.
| Enclosure | Material | Outside H x W x D / display | Rating |
|---|---|---|---|
| 24 × 20 × 10 in | 316L stainless | 24 x 20 x 10 in | Rated NEMA 4X / IP66 by the manufacturer; not UL listed |
| 12 × 10 × 6 in | 316L stainless | 12 x 10 x 6 in | Rated NEMA 4X / IP66 by the manufacturer; not UL listed |
| 20 × 16 × 8 in | 316L stainless | 20 x 16 x 8 in | Rated NEMA 4X / IP66 by the manufacturer; not UL listed |
| 24 × 20 × 8 in | 316L stainless | 24 x 20 x 8 in | Rated NEMA 4X / IP66 by the manufacturer; not UL listed |
Questions
Does a CE mark with an EMC declaration of conformity settle the bridge question?
No. The declaration names standards, often only IEC 61000-6-2 or IEC 61326-1, and both stop at industrial or general locations. Ask for the test report instead: it lists the test levels, the ports exercised during each test, the performance criterion and the degradations observed, none of which the declaration shows. A CE mark backed by an industrial report is still an industrial device on a bridge survey.
Can the enclosure's NEMA 4X or IP66 rating make up for the missing marine test?
No. The enclosure answers water and corrosion; a 316L box keeps spray off the gateway and changes nothing in its test report. What the cabinet does give you is location: moving it across the boundary, out of the assessed bridge space, changes the location the surveyor assesses. That relocation, not the rating, is what usually closes the finding.
Which media may cross from an industrial cabinet onto the bridge?
Tested equipment and passive media. A fiber run crosses cleanly: glass carries light and offers no copper conductor for conducted noise to ride. A shielded copper Ethernet run crosses only when the device at the bridge end carries its own marine evidence and the shield lands on the bridge-side bonding bar, not on a pigtail.
Why does the edition year on an IEC 61326-1 report matter?
Because the 2020 edition extended radiated immunity testing up to 6 GHz. A report to an earlier edition stops lower in frequency, so the top of the range is untested and needs an extension test before anyone maps it against the marine environment. Read the edition on the report cover, not just the standard number.
What do A, B and C mean in the performance-criterion column of an EMC report?
They grade behaviour during the disturbance. A means performance within specification throughout; B means temporary degradation that recovers by itself; C means temporary degradation that needs an operator reset. For a gateway feeding bridge displays you want A on the Ethernet and CAN ports, or a written acceptance of B with the recovery time stated.





