No reference CAD files for this size yet. With your order you approve a dimensioned drawing, the panel sized to your display, before production.
Outdoor display enclosure · 304 stainless
14 × 36 × 12 in 304 stainless outdoor display enclosure with removable sun-shade cover
- Sun shadeits own front cover, locked on top
- Displayabout 11 × 33 × 4 in H × W × D
- Feetabout 34 in centres
- Ships at60 lb packed
- Display fit & sun ↓
Delivered in 10 business days, made to order, anywhere in the world
- 3-year warrantyParts and labor on manufacturing defects, three years from the date you receive the unit.Warranty
- 90-day returnsStandard products, unused, with an RMA number first. Customized, modified or special-order items are not eligible: with a door cutout, operator holes or other changes, ask before ordering.Returns
- Sold by Industrial Monitor DirectSold, shipped and supported by Industrial Monitor Direct, Sanford, Maine.1 (207) 800-1637
- PurchasingNet 30 for approved accounts · W-9 on request · POs welcomeTerms & setup
Another size, material or cutout, from one piece? Build it in 3D or request a quote
- Rating Rated NEMA 4X / IP66 by the manufacturer; not UL listed
- Checkout Secure checkout by Industrial Monitor Direct
- Built-in sun shade
- 304 Stainless Steel
- 14 ga (2.0 mm)
- Removable display panel
- Rear mounting feet
- Drawing before production
- Fleet and custom sizes
Interactive 3D
Turn the 14 × 36 × 12 over
The cover is shown locked on the roof as the sun shade. Drag to rotate, scroll to zoom.

Loading 3D model…
This size in detail
What fits in the 14 × 36 × 12 in
A wide display of about 11 × 33 × 4 in (H × W × D) goes in on the removable interior panel, sized to your exact model before production; you approve a dimensioned drawing first. The display itself is not included: name it in the order note or the quote form.
- Display envelope
- 11 × 33 × 4in (H × W × D), 279 × 838 × 102 mm; the panel is sized to your display model before production
- Front taken by it
- 72 %363 of the front's 504 sq in; about 1.5 in of body round it, walls included
- Depth beside it
- 8 inof the 12 in body depth (203 of 305 mm) that a 4 in deep display leaves, walls and its panel included
- Display shape
- 3 : 133 in wide for 11 in high: a stretched (bar) display; a 16:9 screen 11 in high is only about 19.6 in wide
One cover, two jobs
No separate hood to buy, mount, store or lose.
Overhang up to H − D: a 14 in cover on a 12 in deep roof. The exact figure is on your approval drawing.
Sealed The front cover closes on a continuous gasket and six thumb nuts, for storage, transport and off-season.
Lift off Undo the six thumb nuts by hand and lift the cover away from the front.
Lock on top Set the cover on the four roof collars and tighten it down. It overhangs the front by up to 2 in (51 mm) and keeps direct sun and glare off the screen. The cover is fastened, not just set in place.
Heat it can shed, sealed
≈ 38 W at 10 K · ≈ 77 W at 20 K
Q = k · A · ΔT: A = 1.4·W·(H+D) + 1.8·D·H = 1.041 m² (on a wall, IEC/TR 60890), k = 3.7 W/m²K (stainless, still air, no sun). An estimate, not a rating.
Shed sealed: still air, no sunShed sealed at 10 K ≈ 38 W
Sun: peak ≈ 338 W on the front, 9× what it sheds sealed (off this chart): the cover, locked on the roof, is its shade: what it does in the sun.
In the sun · 14 × 36 × 12 in
What the cover does in the sun
The display adds its own heat on top of the sun: enter its power in the heat check above. With the cover on the roof, the front is open to the display's own face.
Roof under the cover
0.28 m² (3 sq ft), 36 × 12 in
Locked on the four roof collars, the cover covers the whole roof and reaches out over the screen, keeping direct sun and glare off it. Shade from the part that seals the box: nothing extra to mount.
Shields, measured
25–56 % less temperature rise
above ambient in one enclosure maker's tests of its own top, side and wall shields (outdoor guide). This cover has not been tested that way, so no figure is claimed for it.
Colour in full sun
6 vs 28 °C (11 vs 50 °F) white against black
rise above ambient with nothing inside, in the same maker's chart (colour and shade). Bare brushed stainless needs no paint; for the painted version, a light colour gains less.
Areas on this page, each its own count: heat check A = 1.041 m², the IEC/TR 60890 cooling surface (faces weighted for how freely they shed heat); peak sun 0.33 m², the front; roof 0.28 m², what the cover shades; weather faces 1.10 m², every outside face but the back (material).
Condensation Closed for the night or the off-season, the air inside shrinks about 3.3 % in a 30 to 20 °C cool-down and draws outside air in through any worn gasket. In humid air, plan a heater or desiccant. Condensation guide.
304 stainless · 14 × 36 × 12 in
Outdoors year-round: the 14 × 36 × 12 in in 304
304 stainless does not rely on paint, so scratches and UV do not start rust, and the brushed finish still looks right after years in the weather. It is our recommendation for any enclosure that lives outside year-round. Near de-icing salt or salt air, ask us for 316L. Type 304 (UNS S30400): 17.5–19.5 % chromium, 8.0–10.5 % nickel, no molybdenum, carbon 0.07 % max (ASTM A240); pitting resistance (PREN) about 20.
Weather faces
1.10 m² (11.8 sq ft)
Front, top, bottom and both ends of the 14 × 36 × 12; the back goes to the post or wall on its feet. Rinse with fresh water after salt spray or road splash; stainless-only pads and soft cloths, never steel wool.
Cover seal
≈ 2.5 m (100 in) round the front
The cover's continuous gasket follows that edge (its own length not measured). It moves with the cover between the front and the roof: look it over each time, since a torn or flattened run lets rain in when closed.
Chloride for 304
< 200 ppm in rinse water
The Nickel Institute guideline for 304 at ambient temperature; 316L takes up to about 1,000 ppm. Salt air or de-icing salt on the box is the signal to step up.
304 is the call
- Inland parks, trailheads and visitor information
- Transit and kiosk sites away from salted roads
- Rain, snow and hose-down, rinsed off
Step up to 316L
- Within 5–10 miles (8–16 km) of salt water
- Within about 100 m (330 ft) of a salted road, loading dock or parking deck
- Chlorinated or salty water left to dry on it
Ask for 316LPainted steel version
Same size, cover and mounting in either: quoted here, delivered in the same time. The powder-coated version at Industrial Monitor Direct ↗ 304 vs 316L guide
Installation
Mounting the 14 × 36 × 12 in
Mounting it
7 items: feet, centres, fixings, the cover's room, size, sheet
- Mounting feet Two on the rear, two holes each, upright and reaching past the top and bottom of the body
- Foot centres 864 mm (34 in), about 25 mm (1 in) in from each end of the 914 mm body
- Hole spacing along a foot On your approval drawing; the reference drawing gives the foot centres only
- Fixes to A post, rail, wall or kiosk frame
- Cover Lifts off the front once the six thumb nuts are undone by hand, and locks on the four roof collars: leave room above the box and in front of it
- Outside, body only 356 × 914 × 305 mm (H × W × D); the feet, thumb nuts and roof collars extend beyond
- Sheet 2.0 mm (14 ga) 304 stainless
Load on each fixing
≈ 7 kg (15 lb) per hole
27 kg estimated packed shipping weight, ÷ 4 holes (2 feet × 2); the enclosure alone weighs less, and the fixings also carry the display. Over the 23 kg one-person limit: a two-person lift.
Getting it in place Through any standard doorway carried end-on: the body is 14 × 12 in in section (356 × 305 mm) and 36 in long.
Details
Specifications and files
Full specifications
11 rows: sizes, display, sheet, cover, mounting, rating
A sealed 14 × 36 × 12 inch (356 × 914 × 305 mm) enclosure in 14 ga (2.0 mm) 304 stainless steel, #4 brushed, built for a wide display outdoors: trailhead and visitor information, park and campground signage, transit and parking boards, kiosks and equipment status screens. Closed, it is a sealed box that rides out the weather. Open, the same gasketed cover locks on the roof and shades the screen from direct sun and glare.
- Outside dimensions (H x L x D)
- 14 × 36 × 12 in (356 × 914 × 305 mm), body only
- Fits display
- About 11 × 33 × 4 in (H × W × D); tell us your display model and we size the panel to it
- Material
- 14 ga (2.0 mm) 304 stainless steel, #4 brushed
- Sheet thickness
- 2.0 mm (14 ga)
- Rating
- Rated NEMA 4X / IP66 by the manufacturer; not UL listed. For outdoor use.
- Front cover
- Removable, continuous gasket; mounts on top as a sun shade with captive studs and collars
- Mounting
- Two rear mounting feet, two holes each, about 34 in (864 mm) center-to-center
- Interior
- Removable mounting panel for the display
- Drawing
- Dimensioned approval drawing before production
- Shipping weight
- About 60 lb (27 kg) packed
- Lead time
- Made to order; delivered in 10 business days, anywhere in the world

Drawings & CAD
The dimensioned drawing; no CAD files for this size yet
Specification text
For your spec, BOM or tender: copy it, print the datasheet or take the specs as CSV
Enclosure, outdoor display, removable front cover: 304 stainless steel, #4 brushed finish, 2.0 mm (14 ga) sheet. Outside 14 × 36 × 12 in (356 × 914 × 305 mm) H × W × D, body only. Front cover sealing on a continuous gasket, closed with six thumb nuts; it lifts off and locks on four roof collars as a sun shade over the display. Removable interior mounting panel for a display of about 11 × 33 × 4 in (H × W × D), sized to the display model before production. Two rear mounting feet, two holes each, 864 mm (34 in) centre to centre. Rated NEMA 4X / IP66 by the manufacturer; not UL listed. NEMA4 Enclosure IMD-ENC-SS4-143612-SUN, or approved equal.
Dimensions are nominal, from the product drawing and specifications: confirm critical dimensions before cutting or installing. The drawing you approve governs.
What's in the box
The parts, this size's options and what is not included
- Body 304 stainless, #4 brushed
- Front cover Removable, continuous gasket; mounts on top as a sun shade with captive studs and collars
- Cover gasket Continuous, all round the front cover
- Mounting Two rear mounting feet, two holes each, about 34 in (864 mm) center-to-center
- Interior Removable mounting panel for the display
Not included
The display and its fixings, cable glands and the devices that go inside.
Other sizes and fleet orders
Every dimension, cutout and mounting detail can be changed for your display, from one piece to a full fleet, with the same delivery promise. Send the display model or a sketch through the custom enclosure form or reply to your quote, and we return a dimensioned drawing for approval.
304 stainless: is it the right grade?
304 suits indoor washdown, food and beverage lines and most outdoor installs. For coastal air, brine or chlorinated cleaners, choose 316L. Read the 304 vs 316L guide.
Buying guides
Ratings, sizing, heat and cutouts, before you order
Before you order: Outdoor enclosures, NEMA 4 vs 4X vs IP66, Heat calculation and 304 vs 316L stainless. All guides.
Spotted a wrong number or a broken file? Report a problem with this page.
Questions about this size
14 × 36 × 12 in: asked and answered
Which display fits the 14 × 36 × 12?
A wide display of about 11 × 33 × 4 in (H × W × D; 279 × 838 × 102 mm), on the removable interior panel. Name your display model in the order note or the quote form: the panel is sized to it before production, and you approve a dimensioned drawing first. The display itself is not included. A bigger display or another shape takes a bigger body, made to order: ask for a quote.
Is it sealed while the display is showing?
Closed, it is sealed: the front cover closes on its continuous gasket under six thumb nuts. Rated NEMA 4X / IP66 by the manufacturer; not UL listed. With the cover on the roof as the sun shade, the front is open to the display's own face, so the display then meets the weather: check its outdoor rating in its datasheet, and close the cover for storage, transport and the off-season.
How does the sun-shade cover work?
Sealed: the front cover closes on a continuous gasket and six thumb nuts, for storage, transport and off-season. Lift off: undo the six thumb nuts by hand and lift the cover away from the front. Lock on top: set the cover on the four roof collars and tighten it down. It overhangs the front and keeps direct sun and glare off the screen. The cover is fastened, not just set in place. No separate hood to buy, mount, store or lose.
How is the 14 × 36 × 12 mounted?
On two rear feet on the rear, two holes each, 34 in (864 mm) centre to centre, for a post, rail, wall or kiosk frame. The hole spacing along each foot is on your approval drawing. It ships at about 60 lb (27 kg) packed, so it is a two-person lift, and the fixings also carry the display. Leave room above the box and in front of it to move the cover.
Will the display overheat in the sun?
Sealed, the box sheds about 38 W at 10 K and 77 W at 20 K above ambient (1.04 m² × k 3.7 W/m²K, IEC/TR 60890, no sun), and peak sun on the front alone is about 338 W. On the roof, the cover shades the top and the screen; in one maker's tests shields cut the temperature rise above ambient by 25 % to 56 % (outdoor guide), not measured on this cover. Add your display's power in the heat check, or size cooling in the heat calculator.
Is 304 stainless right for the 14 × 36 × 12, or does it need 316L?
Yes for indoor sites, routine washdown and most inland outdoor sites: the Nickel Institute guideline puts 304 at water under about 200 ppm chloride. Near salt water or de-icing salt, or where brine or chlorinated sanitizers are left on the surface, take a 316L build, made to order on a quote (request one). The 2.0 mm body and front cover are 304 stainless. Cleaning: 304 is corrosion proof in nitric acid, caustic soda and hydrogen peroxide, but hot organic acids and sulfuric acid call for 316L, and bleach must be rinsed off; see the cleaning-chemicals table.
How do I clean the 14 × 36 × 12?
Fresh water and a soft cloth or a stainless-only pad, then rinse; never steel wool or grinding dust, which leave iron that stains. Rinse de-icing salt splash and chlorinated cleaners off before they dry. Look the cover gasket over each time the cover moves between the front and the roof.
How long does it take?
Made to order and delivered in 10 business days, anywhere in the world, counted from your order; a custom size or panel from your approval of the drawing.
Custom versionRequest a quote for the 14 × 36 × 12 in enclosure
Another size, extra holes, your drawing or a quantity quote: quoted by email, built from one piece.Open the quote form
Another size, extra holes, a different cutout, your own drawing or a quantity quote: tell us what you need and attach a drawing if you have one. Custom work is quoted, not priced online, and built from one piece.
- Quote by email Our engineers check your request and reply usually within one business day.
- Drawing You approve a dimensioned drawing before anything is cut.
- 10 business days From that approval to delivery, anywhere in the world.
This 304 enclosure is rated NEMA 4X / IP66 by the manufacturer; not UL listed. Once cutouts are added, the rating of the finished enclosure depends on properly rated components and cable glands being installed in every opening.