A wall-mounted enclosure has two different mounting jobs.

2
00:00:04.250 --> 00:00:06.310
The internal backplate carries equipment.

3
00:00:06.830 --> 00:00:09.770
The external feet connect the enclosure to its support.

4
00:00:10.350 --> 00:00:12.990
This exploded view shows how the parts fit together.

5
00:00:14.642 --> 00:00:19.942
The mounting panel shown here is galvanized steel, supported on welded studs inside the

6
00:00:19.942 --> 00:00:20.422
enclosure.

7
00:00:21.142 --> 00:00:25.522
Plan the devices, rails, wire ducts and cable routes on that panel.

8
00:00:26.082 --> 00:00:29.882
Check the usable area, depth and permitted load for the complete assembly.

9
00:00:31.558 --> 00:00:34.658
The four external feet are the enclosure's mounting points.

10
00:00:35.378 --> 00:00:37.798
Use the hole pattern on the exact model drawing.

11
00:00:38.418 --> 00:00:43.338
Select fasteners and a supporting wall or frame for the full installed load, including

12
00:00:43.338 --> 00:00:46.298
the enclosure, backplate, equipment and cables.

13
00:00:48.017 --> 00:00:52.357
Check the space in front and at the hinge side before choosing the location.

14
00:00:53.137 --> 00:00:57.977
The door must open for installation and servicing, without hitting nearby equipment.

15
00:00:58.717 --> 00:01:02.257
Use the model drawing and the working-space requirements for the installation.

16
00:01:04.017 --> 00:01:07.597
The gasket and door closure are part of the enclosure's protection.

17
00:01:08.317 --> 00:01:10.977
Keep the sealing surfaces clean and undamaged.

18
00:01:11.577 --> 00:01:15.157
Do not assume a new hole or accessory preserves the rating.

19
00:01:15.817 --> 00:01:20.217
Review cable entries and other modifications as part of the complete installation.

20
00:01:21.933 --> 00:01:26.773
Before mounting, check the equipment layout on the backplate, the full load at the

21
00:01:26.773 --> 00:01:30.253
external feet, and the space to open and service the enclosure.

22
00:01:31.073 --> 00:01:36.073
Start with the exact product drawing, then verify the finished installation against its

23
00:01:36.073 --> 00:01:36.513
instructions.